INSTALLATION INSTRUCTIONS

AND

OWNER’S MANUAL

VENTED

ROOM HEATER

MODELS

RH-50-6

RH-65-6

RH-50C-1

RH-65C-1

EFFECTIVE DATE

APRIL 2006

–  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

–  WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use 

any phone in your building.

• Immediately  call  your  gas  supplier  from  a 

neighbor’s phone. Follow the gas supplier’s 

instructions.

• If you cannot reach your gas supplier, call the 

fire department.

–  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

WARNING: If the information in this manual 

is not followed exactly, a fire or explosion may 

result  causing  property  damage,  personal  in-

jury or loss of life.

Installer: Please leave these instructions with the 

consumer.

Consumer:  Please  retain  these  instructions  for 

future use.

WARNING: If not installed, operated and main-

tained in accordance with the manufacturer’s in-

structions, this product could expose you to sub-

stances in fuel or from fuel combustion which can 

cause death or serious illness.

Содержание RH-50-6

Страница 1: ...s supplier s instructions If you cannot reach yourgas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal in jury or loss of life Installer Please leave these instructions with the consume...

Страница 2: ...Reversible Vertical or Horizontal Diverter 8 Thermostat Operation 8 Lighting Instructions 9 Pilot Flame Characteristics 10 Main Burner Flame Characteristics 10 Maintenance 11 Troubleshooting 11 How to Order Repair Parts 12 Parts List RH 50 RH 65 12 Parts View RH 50 RH 65 13 Parts List RH 50C RH 65C 14 Parts View RH 50C RH 65C 15 Optional Blower Installation Instructions 16 17 Service Notes 18 SECT...

Страница 3: ... before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the room heater be kept clean DO NOT put anything around the heater that will ob struct the flow of combustion and ventilation air See clearances DO keep t...

Страница 4: ...n occur in new tanks or reinstalled old tanks if they are filled and allowed to set too long before refilling Cylinders and tanks which have been out of service for a time may develop internal rust which will cause odor fade If such conditions are suspected to exist a periodic sniff test of the gas is advisable If you have any question about the gas odor call your LP gas dealer A periodic sniff test...

Страница 5: ...ve is engaged in and is respon sible for 1 the installation or replacement of gas piping or b the connection installation repair or servicing of equipment who is experienced in such work familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction The installation must conform with local codes or in the absence of local codes with the Natio...

Страница 6: ...est with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which conde...

Страница 7: ...mbustion Air Room heaters shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions In buildings of conventional frame brick or stone construction without tight storm windows and doors infiltration is normally adequate to provide for combustion and draft hood dilution Whereappliancesareinstalledinaconfine...

Страница 8: ... switch from the draft diverter 2 Inside your yellow instruction envelope will be a 1 1 2 x 2 1 4 38mm x 51mm vent safety switch hole cover plate and two 2 1 2 screws for attachment of vent safety switch hole cover plate to the draft diverter Attach vent safety switch hole cover plate over hole on the draft diverter from which the L280 vent safety switch was removed 3 Remove two 2 screws at bottom...

Страница 9: ...the floor If you smell gas STOP Follow B in the safety information above on this label If you do not smell gas go to the next step 7 Find pilot the pilot is attached to front of burner 8 Turn gas control knob counterclockwise to IGN 9 Depress and turn gas control knob counterclockwise to PILOT Aspark is produced when gas control knob is turned between IGN and PILOT Repeatedly depress and turn gas c...

Страница 10: ...IN BURNER FLAME CHARACTERISTICS There will be a short blue inner flame with a larger lighter blue secondary flame The burner flame may have yellow tips when hot Dust in the combustion air will produce and orange or red flame Do not mistake the orange or red flame for an improper yellow flame The flame will be proper if the factory set pressure and orifice are used After use cleaning may be required for th...

Страница 11: ...ot be removed from main burner by using primary air adjustment bolt the air shutter bracket can be pivoted upward to allow additional primary air to enter burner throat On Propane gas if a whistling noise resonation occurs screw the air adjustment bolt into the burner throat to eliminate the whistling noise resonation TROUBLESHOOTING 1 Impossible to light pilot a If using piezo ignitor check elect...

Страница 12: ... 6 LPG 5 11707 Louver RH 50 6 3 required RH 65 6 4 required 27 11746 Valve Bracket 6 11745 Casing Back 28 R 6101 Gas Valve Nat 7 RH 652 Combustion Chamber Assembly RH 50 6 28 R 6102 Gas Valve LPG 7 RH 626 Combustion Chamber Assembly RH 65 6 29 11743 Control Rod 8 RH 654 Chamber Shield Right RH 50 6 30 11700 Control Rod Bracket 8 RH 655 Chamber Shield Right RH 65 6 31 R 6096 Knob Adaptor Set 9 1172...

Страница 13: ...12822 3 0406 Page 13 PARTS VIEW RH 50 RH 65 ...

Страница 14: ...7 Main Burner Orifice RH 50C 1 LPG 8 RH 654 Chamber Shield Right RH 50C 1 23 11746 Valve Bracket 8 RH 655 Chamber Shield Right RH 65C 1 24 R 6101 Gas Valve NAT 9 11721 Casing Side RH 50C 1 24 R 6102 Gas Valve LPG 9 11722 Casing Side RH 65C 1 25 11743 Control Rod 10 RH 618 Inner Front 26 11700 Control Rod Bracket 11 RH 625 Bottom Reflector RH 50C 1 27 R 6096 Knob Adaptor Set 11 RH 660 Bottom Reflector...

Страница 15: ...12822 3 0406 Page 15 PARTS VIEW RH 50C RH 65C ...

Страница 16: ...tep 1 in the even the blower housing is removed from room heater Attention Bottom reflector and rear shield must be at tached to bottom assembly whenever the blower housing in removed from the room heater and the room heater is in operation 5 Remove switch box cover from the switch box by removing the 8 x 1 4 6mm hex head screw 6 There are two screw holes on the lower back of the combus tion chambe...

Страница 17: ...l electrical source is utilized This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for grounding can be purchased plugged into the ungrounded ...

Страница 18: ...12822 3 0406 Page 18 SERVICE NOTES ...

Страница 19: ...12822 3 0406 Page 19 SERVICE NOTES ...

Страница 20: ...22 3 0406 Page 20 SERVICE NOTES Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ...

Отзывы: