For Your Safety

Due to high temperatures, the appliance should be located out of
traffic and away from furniture and draperies. 

Children and adults should be alerted to the hazard of high surface
temperature and should be kept away to avoid burns or clothing
ignition.

Installation and repair should be done by a qualified service person. 

This series is design certified in accordance with American National
Standards Institute Z21.86 (latest standard) and CSA2.32-(latest
standard) by the Canadian Standards Association, as a Vented Wall
Furnace.

The installation must conform to local codes. In the absence of local
codes, the installation must conform with American National Standard
(National Fuel Gas Code) known as NFPA 54 and ANSI Z223.1 (latest
edition) available from the American National Standards Institute, Inc.,
11 West 42nd St., New York, N.Y. 10036, or from the National Fire
Protection Assoc., Batterymarch Park, Quincy, Massachusetts 02269.

Note: A vent safety switch is standard on all models, automatically
shutting off the heater in the event of a blocked flue or incorrect
installation. (Example: Attaching a 90° elbow directly to the draft
diverter is an incorrect installation.) The flue pipe diameter must be as
large as the flue collar on the draft diverter and run as directly as
possible to the chimney with a minimum of elbows. Any flue pipe
passing through walls and roof must be “B” Type vent. The chimney
must extend at least two feet above the roof and any object or
building within ten feet of the chimney.

Read your Owner's Manual for complete installation and safety information.

www.empirecomfort.com

Specifications

Gravity Wall Furnaces  

25,000 to 50,000 Btu Models

GWT-50

Model

GWT-25

GWT-35

Dual Wa

ll

Color: Cabinet and Front Panel

Beige

Beige

Beige

Btu Input

25,000

35,000

50,000 (Total)

25,000 (Each Room)

Overall Dimensions 

(unit mounts between standard stud spacing) 

Width Casing

16" 

16"

16"

Depth Casing

6"

6"

6"

Height 66 

1

/

8

"

66 

1

/

8

"

66 

1

/

8

"

Height with Optional Blower Kit

71 

7

/

8

"

71 

7

/

8

"

71 

7

/

8

"

Shipping Weight, Lbs. (One Carton)

86

86

133

Accessories 

(State on Order)

Wireless Remote Wall Thermostat

TRW

TRW

TRW

750mv Wall Thermostat (Reed Switch)

TMV

TMV

TMV

750mv Wall Thermostat

GWSG-T

GWSG-T

GWSG-T

Remote Bulb Thermostat

GWRB-T

GWRB-T

GWRB-T

Blower Kit

GWTB-2

GWTB-2

GWTB-2†

Output, Cu. Ft./Min.

75

75

75

Rear Register Kit

GWTR-1

GWTR-1

N/A

Out-of-the-Wall Installation Kit

GWTW-2**

GWTW-2**

N/A

Minimum Clearance to Combustibles from:

Top

12" 12"

12"

Each Side

4"

4"

4"

Bottom of Unit to Floor Covering

1

1

/

2

" 1

1

/

2

"

1

1

/

2

"

Gas Inlet

Type of Gas (State on Order)

Natural or LP

Natural or LP 

Natural or LP 

Iron Pipe Size (N.P.T.)

1

/

2

"

1

/

2

"

1

/

2

"

Venting

Size of Flue Collar (Type B) 

4" Oval

4" Oval

4" Oval

Safety Control

Pilot and Main Burners Include Automatic Shutoff

Warranty

Combustion chamber carries a 10-year limited warranty. 
All other parts carry a 1-year limited warranty.

One blower may be purchased for each side.

** When the GWTW-2 Out-of-the-Wall kit is used, 

the GWTR-1 Rear Register kit cannot be used.

GWSG-T

Wall

Thermostat

GWRB-T

Remote Bulb

Thermostat

115 VOLT OUTLET 
BOX FOR OPTIONAL 
HARDWIRING OF 
OPTIONAL BLOWER

HEADER PLATE

BOTTOM OF 
HEADER 
NAILING
FLANGE

B-VENT WITH 
BW ADAPTER*

GASKET FOR 
HEADER
ASSEMBLY

BASE PLATE

HEADER 
PLATE

2 x 4
STUDS

2 x 4 FLOOR PLATE

2 x 4 FLOOR PLATE

66 

1

/

8

"

WALL 

OPENING

62 

1

/

4

"

14 

1

/

2

"

INSIDE

Header is provided with furnace. However, if it is desired
to finish wall before furnace is delivered, the header may
be ordered and installed prior to delivery of furnace.

Note: Construction deeper than standard (2x4 stud) may
create installation problem. Contact Empire for
additional information. GWT-50 will not work on walls
with deeper than 2x4 construction.

* Purchase Locally

Note: Empire has a policy of constantly improving quality
and performance of its appliances, therefore, materials and
specifications are subject to change without notice.

Note: Units do not come with thermostats.

Inshot Burner & 

Tubular Heat Exchanger

GWTB-2 Blower

*

Отзывы: