Introduction

Always  consult  your  local  Building  Department  regarding 
regulations, codes or ordinances which apply to the installation of 
a direct vent wall furnace.

Instructions to Installer

1.  Installer  must  leave  instruction  manual  with  owner  after 

installation.

2.  Installer must have owner fill out and mail warranty card supplied 

with furnace.

3.  Installer should show owner how to start and operate furnace 

and thermostat.

4.  Installer must locate unit near a grounded wall receptacle for 

115VAC power and must provide gas supply and vent the unit 
properly for safe operation.

Warning:
Any change to this furnace or its control can be dangerous.  
This is a heating appliance and any panel, door or guard 
removed for servicing an appliance must be replaced prior 
to operating the appliance.

General Information

This series is design certified in accordance with American National 
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian 
Standards Association as a Fan Type Direct Vent Wall Furnace to 
be installed according to these instructions.

Any  alteration  of  the  original  design,  installed  other  than 
as shown in these instructions  or use with a type of gas not 
shown on the rating plate is the responsibility of the person and 
company making the change.

Important

All correspondence should refer to complete Model Number, Serial 
Number and type of gas.

Notice: 

 During initial firing of this unit, oil from the heat exchanger 

may bake out  and smoke may occur.  To prevent triggering of smoke 
alarms, ventilate the room in which the unit is installed.

Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed 
so that all burners and burner ignition devices are located not less 
than 18" (457mm) above the floor.

Such equipment shall be located, or protected, so it is not subject 
to physical damage by a moving vehicle.  

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment 
or  accessories  and  repair  and  servicing  of  equipment  shall  be 
performed only by a qualified agency.  The term "qualified agency" 
means any individual, firm, corporation or company which either in 
person or through a representative is engaged in and is responsible 
for  (a)  the  installation  or  replacement  of  gas  piping  or  (b)  the 
connection, installation, repair or servicing of equipment, who is 
experienced in such work, familiar with all precautions required 
and has complied with all the requirements of the authority having 
jurisdiction.

State  of  Massachusetts: 

The  installation  must  be  made  by 

a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.

The installation must conform with local codes, or in the absence 
of local codes, the National Fuel Gas Code, ANSI  Z223.1/NFPA 
54 or Natural Gas and Propane Installation Code, CSA B149.1. 
*Available from the American National Standards Institute, Inc., 
11 West 42nd St., New York, NY 10036.

A manufactured home (USA only) or mobile home OEM  installation 
must conform with the Manufactured Home Construction and Safety 
Standard, Title 24 CFR, Part 3280, or, when such a standard is not 
applicable, the Standard for Manufactured Home Installations, ANSI 
Z225.1, or Standard for Gas Equipped Recreational Vehicles and 
Mobile Housing, CSA Z240.4.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), input ratings should 
be reduced at the rate of 4 percent for each 1,000 feet (305m) above 
sea level, this may be accomplished by reducing manifold pressure.  
The maximum allowable reduction in manifold pressure for Natural 
gas shall be from 3.5" w.c. (.872kPa) to 2.8" w.c.  (.697kPa).  The 
maximum allowable reduction in manifold pressure for Propane 
(LP) gas shall be from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa). 
For Canadian high altitude applications, this appliance is suitable 
for installation at elevations between 0 feet (0m) and 4,500 feet 
(1,372m) without change. 

Model

DV-55E

Input BTU/HR (KW/H)

55,000 (16.1)

Height

26" (660mm)

Width

37" (940mm)

Depths with Shroud

15 3/4" (400mm)

Gas Inlet (Pipe)

1/2" (13mm)

Electrical - Unit has a 5' (1.5m) 3 pronged cordset for connec-

tion  to  an  approved  115  VAC  60HZ  maximum 
AMPs - 5A wall receptacle.

Accessories for DV-55E Furnaces

Extended Vent Terminal
    For walls up to 32" (813mm)

DVT-2

Floor Pad

DVP-1

INTRODUCTION

SPECIFICATIONS

 ACF Greenhouses 

Содержание DV-55E

Страница 1: ...his appliance is only for use with the type s of gas indicated on the rating plate A conver sion kit is supplied with the appliance Installer Leave this manual with the appli ance Consumer Retain this...

Страница 2: ...assachusetts 5 Introduction 6 Specifications 6 Gas Supply 7 Gas Conversion Instructions 8 Clearances 9 Furnace Installation 9 11 Lighting Instructions 12 Wiring 13 Maintenance 14 Operation and Trouble...

Страница 3: ...nstallation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected beforeuseandatleastannuallybyaqualifiedserviceperson More frequent cleaning may be required due to...

Страница 4: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption...

Страница 5: ...naccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshall be permanently mounted to the exterior o...

Страница 6: ...be performed only by a qualified agency The term qualified agency meansanyindividual firm corporationorcompanywhicheitherin person or through a representative is engaged in and is responsible for a th...

Страница 7: ...ontrol valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the g...

Страница 8: ...ning Conversion must be done by a qualified service technician Main burner orifice s and new gas conversion label are provided in conversion kit attached to manifold pipe 1 Make sure gas supply to fur...

Страница 9: ...NG The nearest point of the vent cap should be a minimum horizontal distant of six 6 feet 1 83m from any pressure regulator In case of regulator malfunction the six 6 feet 1 83m distance will reduce t...

Страница 10: ...if plastic anchors are used Attach the two wall mounting brackets to the casing back by using 4 10 x 1 2 13mm hex head screws provided Figure 5 Figure 6 Figure 7 Figure 8 2 51mm TO 13 330mm 2 51mm TO...

Страница 11: ...ach the right shroud and left shroud to the casing back the 3 4 wide flange on the shroud must be positioned toward the casing side When positioned correctly the 6 louvers on the shroud will be facing...

Страница 12: ...lified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 STOP Read the safety information above 2 Set the therm...

Страница 13: ...VAC circuit If current is below 1 micro amp remove sensor clean with light sandpaper and retest Note This heater is equipped with a remote bulb electronic thermistor control located down low at the ba...

Страница 14: ...lve 4 Remove gas valve from gas valve bracket Removing Main Burner Orifice s 1 Remove front grill assembly 2 Remove burner compartment access panel 2 screws 3 Disconnect manifold union assembly 4 Disc...

Страница 15: ...terminal on the board The inducer blower circuit is energized and the inducer blower comes on for 15 seconds pre purging out any gas and closing the pressure switch The hot surface ignitor is energize...

Страница 16: ...essure switch is closed with inducer off Check Pressure Switch and Replace 4 Flashes Lockout due to failed ignition Check for Broken Ignitor Check for Bent Ignitor Bracket Ignitor too far from Burner...

Страница 17: ...e Description of each part from the following appropriate illustration and list Be sure to give all this information Furnace Model Number Part Description Furnace Serial Number Part Number Type of Gas...

Страница 18: ...19563 3 0907 Page 18 PARTS VIEW ACF Greenhouses...

Страница 19: ...19563 3 0907 Page 19 SERVICE NOTES ACF Greenhouses...

Страница 20: ...3 0907 Page 20 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ACF Greenh...

Отзывы: