The firebox is designed to accept a 3/8-inch gas line for an approved
vent-free gas logset. Have the line installed by a qualified service
person in accordance with all building codes. Consult local building
codes to properly size the gas supply line leading to the 3/8-inch
hook-up at the unit. The state of Massachusetts requires that a
flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox.
See
Figure 10
. On units with ceramic liners installed, carefully remove
the indented knockout in the ceramic brick panel using a drill or
utility knife.
See Figure 11.
Check gas type. Use only the gas type indicated on the gas log
set rating plate. If the gas listed on the plate is not your type of gas
supply, DO NOT INSTALL. Contact your dealer for proper model.
Always use an external regulator for all LP fireboxes to reduce the
supply tank pressure to a maximum of 14" w.c. This is in addition
to the regulator fitted to the log set.
WARNING: CONNECTION DIRECTLY TO AN UNREGULATED
L.P. TANK CAN CAUSE EXPLOSION.
Install only a ANSI Z21.11.2 vent-free log set into this firebox.
Figure 10
Extended Hoods
If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that will
extend out 2" farther out into the room. Contact your local dealer for details.
Finishing
All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-
combustible material.
Hearth extensions are recommended, but not required for these fireboxes.
VB4H32BL
Standard Black
VB4H36BL
Standard Black
VB4H42BL
Standard Black
VB4H32BR
Polished Brass
VB4H36BR
Polished Brass
VB4H42BR
Polished Brass
VB4H32SS
Stainless Steel
VB4H36SS
Stainless Steel
VB4H42SS
Stainless Steel
VB4H32HP
Hammered Pewter
VB4H36HP
Hammered Pewter
VB4H42HP
Hammered Pewter
GAS ACCESS HOLES
Figure 11
INSTALLING HOOD (continued)
GAS LINE CONNECTION