39005-0-1018
Page 10
OPTIONAL FreSh AIr KIT INSTALLATION INSTrucTIONS
3. Insert Slide Assembly through the cut-out as shown in
Figure
15
. Before you fasten ensure that the handle penetrates the
inner firebox wall.
See Figure 16.
Fasten the Slide Assembly
with the four 10 x 1/2 Hex Head Screws provided.
Figure 15
Figure 16
The optional Fresh Air Kit is designed to introduce outside air to
the firebox as desired. It must be installed prior to, or at the time of
firebox installation to framing. The Fresh Air kit must be installed
prior to the installation of wallboard or other finishing materials
around the unit.
Hardware needed (not provided):
•
4 inch Aluminum Flex Duct
•
2 Band Clamps
Tools needed:
•
Gloves
•
Metal snips
•
5/16 inch Nut Driver
•
Phillips Screwdriver
cAuTION
Sharp edges, wear gloves.
Slide Assembly Installation
1. Begin by removing the rectangular cutout located on the left
side of the unit. Use gloves and sheet metal snips to create
the opening for the Air Door assembly to install into.
See
Figure 13
.
Figure 13
2. Bend the tab out of the way.
See Figure 14.
Figure 14