Empire Comfort Systems VFP32FB0F-5 Скачать руководство пользователя страница 9

33742-1-0614

Page 17

33742-1-0614

Page 16

Keep the control compartment, logs and burner area surrounding 

the logs clean by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer 

to lighting instructions located on the log set.

Never obstruct the flow of the combustion and ventilation air. Keep 

the front of the firebox clear of all obstacles and materials.
Screens must be closed during operation.

JUNcTION BOX wIRING INSTALLATION INSTRUcTIONS

MAINTENANcE

To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.

com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the 

nature of the problem with the unit. 

To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below. 

This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com.

Please  note:  Master  Parts  Distributors  are  independent  businesses  that  stock  the  most  commonly  ordered  Original 

Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. 

MASTER PARTS DISTRIBUTOR LIST

Parts Not Under warranty

Parts can be ordered through your Service Person, Dealer, or a Master Parts Distributor. See this page for the Master Parts Distribu

-

tors list.  For best results, the 

service person or dealer

 should order parts through the distributor. Parts can be shipped directly to the 

service person/dealer

.

warranty Parts

Warranty parts will need a proof of purchase and can be ordered by your Service Person or Dealer. Proof of purchase is 

required

 for 

warranty parts.
All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number and Serial Number from the 

name plate on your equipment. Then determine the Part Number (

not

 the Index Number) and the Description of each part from the fol

-

lowing illustration and part list. Be sure to give all this information . . .

Appliance Model Number  

      Part Description 

Appliance Serial Number 

 

Part Number  

Type of Gas (Propane or Natural) 

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 
Shipments contingent upon strikes, fires and all causes beyond our control.

hOw TO ORDER REPAIR PARTS

Dey Distributing

1401 Willow Lake Boulevard

Vadnais Heights, MN 55101

Phone: 

651-490-9191

Toll Free:

 800-397-1339

Website:

 www.deydistributing.com

Parts: heater, hearth and Grills

Victor Division of F. W. Webb Company

200 Locust Street

Hartford, CT 06114

Phone:

 860-722-2433

Toll Free: 

800-243-9360

Fax: 

860-293-0479

Toll Free Fax:

 800-274-2004

Websites: 

www.fwwebb.com & www.victormfg.com

Parts: heater, hearth and Grills

East coast Energy Products

10 East Route 36

West Long Branch, NJ 07764

Phone: 

732-870-8809

Toll Free:

 800-755-8809

Fax: 

732-870-8811

Website: 

www.eastcoastenergy.com

Parts: heater, hearth and Grills

Able Distributors

2501 North Central Avenue

Chicago, IL 60639

Phone: 

773-889-5555

Toll Free:

 800-880-2253

Fax:

 773-466-1118

Website: www. abledistributors.com

Parts: heater

cAUTION: ALL wIRING ShOULD BE DONE By A QUALIFIED 

ELEcTRIcIAN AND ShALL BE IN cOMPLIANcE wITh ALL 

LOcAL, cITy AND STATE BUILDING cODES. BEFORE MAKING 

ThE ELEcTRIcAL cONNEcTION, MAKE SURE ThAT MAIN 

POwER SUPPLy IS DIScONNEcTED. ThE APPLIANcE, 

whEN INSTALLED, MUST BE ELEcTRIcALLy GROUNDED IN 

AccORDANcE wITh LOcAL cODES OR, IN ThE ABSENcE 

OF LOcAL cODES, wITh ThE NATIONAL ELEcTRIcAL cODE 

ANSI/NFPA 70 (LATEST EDITION)

A factory installed junction box is located on the lower right hand side 

of the firebox. Wiring must be fed to the junction box and attached 

to  the  receptacle  that  is  provided.  Remove  the  knockout  in  the 

installed junction box to accept wiring into the junction box. Install 

a UL listed cable clamp (not supplied) in the knockout hole. Leave 

approximately 6 inches of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to 

opposite side of receptacle. The ground wire should be attached 

to the green (neutral) screw.

Install the receptacle into the junction box. Attach cover plate.

Figure 29

Содержание VFP32FB0F-5

Страница 1: ...Ventless Fireplace Enclosures for Gas Fired Decorative Type Unvented Room Heaters WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to l...

Страница 2: ... must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with firebox 3 Installer should show owner how to start and operate log set that is installed into firebox Important AllcorrespondenceshouldrefertocompleteModelNumber Serial Number Notice During initial firing of this firebox with a log set installed its paint will bake...

Страница 3: ... be less than 84 inches to the bottom of the firebox See Figure 3 Mantel Clearances Vent free firebox models must use the hood supplied with the firebox or one of the optional hood kits available for each model If a combustible mantel is installed it must meet the clearance requirements detailed below Leave at least 36 inches clearance from the front of the firebox CLEARANCES Figure 1 Figure 2a Lo...

Страница 4: ...sistance with this planning Planning Your Installation Please note that the optional VFA2 Fresh Air kit available for use with the Vent Free Firebox must be installed at the time of the initial installation Refer to pages 10 11 and 12 for detailed instructions for the air kit Accessory kits such as the FBB5 Blower kit Trim kits Mantles Full Cabinet Mantels plus other Decorative Frame Hood and Door...

Страница 5: ... line installed by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 3 8 inch hook up at the unit The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length Gas access holes are provided on both sides of the firebox See Figure 11 When installing optional c...

Страница 6: ...s shown in Figure 16 5 Push the handle for Open position and pull the handle for the Closed position See Figure 17 Figure 17 Completion of Air Kit installation 1 Determine the length of 4 inch diameter rigid or flex duct con nector installer supplied you will need from the firebox fire place to the exterior surface of the outside wall where the air kit hood will be installed Add a few extra inches...

Страница 7: ...ON OFF wall switch or optional SCV1 Vari able Speed Control Kit should be installed to activate pow er to the fireplace and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 20 1 If installed turn OFF gas supply to firebox gas log 2 If applicable turn OFF electric supply to firebox CAUTION ALL WIRI...

Страница 8: ... complete the installation plug the power cord into the junc tion box receptacle at the right rear corner of the firebox outer wrap See Figure 26 Figure 26 11 If room permits the power cord can be located from the out side of the unit looking through the junction box access hole with the junction box removed then plug up the power cord before reinstalling the pre wired junction box 12 Once all con...

Страница 9: ...each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments contingent upon strikes fires and all causes beyond our control H...

Страница 10: ...25447 25447 25447 BLOWER COVER PLATE 5 R7051 R7051 R7052 R7052 R7053 R7053 ROD SCREEN QUANTITY 2 6 20468 20468 21087 21087 33607 33607 HOOD 7 R9292 R9292 R9292 R9292 R9292 R9292 HEARTH LEDGE RIGHT 8 R9293 R9293 R9293 R9293 R9293 R9293 HEARTH LEDGE LEFT 9 R9294 R9294 R9295 R9295 R9296 R9296 HEARTH LEDGE CENTER 10 23004 23004 23004 23004 23004 23004 HEARTH RETAINER 11 33026 33027 33028 33029 33030 3...

Страница 11: ... optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all avail able optional frame kit ac cessories Decorative Frame Kits Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all avail able optional decorative door kit accessories ACCESSORIES continued Accessory Description Model Numbers Fan Kit Designed to provide...

Страница 12: ... thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify purch...

Страница 13: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Отзывы: