Figures 13, 15 and 17 show a correct pilot flame pattern. The correct
flame will be blue and will extend beyond the thermocouple. The
flame will surround the thermocouple just below the tip. A slight
yellow flame may occur where the pilot flame and main burner flame
meet. Figures 14, 16 and 18 show an incorrect pilot flame pattern.
The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the
heater will shut down.
MILLIVOLT PILOT
Correct Pilot Flame Pattern
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Figure 13
Incorrect Pilot Flame Pattern
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Figure 14
If pilot flame pattern is incorrect, as shown in Figure 14
• See Troubleshooting, page 24.