Figures 22 and 24 show a correct pilot flame pattern. The correct 

flame will be blue and will extend beyond the thermocouple. The 

flame will surround the thermocouple just below the tip. A slight 

yellow flame may occur where the pilot flame and main burner flame 

meet. Figures 23 and 25 show an incorrect pilot flame pattern. The 

incorrect pilot flame is not touching the thermocouple. This will 

cause the thermocouple to cool. When the thermocouple cools, the 

heater will shut down.

MILLIVOLT pILOT

Correct pilot Flame pattern

Figure 22

 

Incorrect pilot Flame pattern

Figure 23

If pilot flame pattern is incorrect, as shown in Figure 23

•  See Troubleshooting, page 28.

HyDRAULIC THERMOSTAT pILOT

Correct pilot Flame pattern

Figure 24

Incorrect pilot Flame pattern

Figure 25

If pilot flame pattern is incorrect, as shown in Figure 25

•  See Troubleshooting, page 28.

PILOT FLAME CHARACTERISTICS

THERMOPILE

PILOT

THERMOCOUPLE

(LPG)

THERMOCOUPLE

(NATURAL)

THERMOPILE

PILOT

THERMOCOUPLE

(LPG)

THERMOCOUPLE

(NATURAL)

Содержание VFP20IN20

Страница 1: ...aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not con...

Страница 2: ...wer Accessory Information 18 VFP20IN Log Placement 19 VFP20IN Ember Placement Photos 20 VFP28IN Log Placement 21 VFP28IN Ember Placement Photos 22 Hydraulic Thermostat Lighting Instrutions 23 Millivol...

Страница 3: ...ure and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room with the appliance Do not place clothing or other flammable ma...

Страница 4: ...rform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls...

Страница 5: ...by bending the shutter cap holding the orifice to the inlet of the venturi tube Ceiling Fans Portable Fans or Logs Installed Near Cold Air Returns Ceiling fans or oscillating floor type fans need to...

Страница 6: ...affect the Btu output of the unit Contact the gas company for the heating value Contact the manufacturer or your gas company before changing spud orifice size WARNING This appliance is equipped for na...

Страница 7: ...r Opening Full Open 1 8 VFP20IN2 L LP NAT Input Btu hr Maximum 20 000 20 000 Btu hr Minimum 10 000 10 000 Orifice 55 43 Air Shutter Opening Full Open 1 8 VFP20IN3 L LP NAT Input Btu hr Maximum 20 000...

Страница 8: ...e The following statement is also provided on a separate label plate in the instruction packet Prior to installation of the fireplace insert the installer must mechanically secure this warning plate t...

Страница 9: ...blower 120V 60Hz 1 Amp Proper opening size of fireplace required for installation of the fireplace insert A D C B Figure 2 VF FIREPLACE INSERT DIMENSIONS MODEL A B C D E F G H I J K VFP20IN 19 3 4 28...

Страница 10: ...ront of the fireplace flush with a wall If installing a mantel above the fireplace you must follow the clearances shown in Figures 9 and 10 Follow the instructions below to install the fireplace in th...

Страница 11: ...o areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other o...

Страница 12: ...om see option 3 Figure 5 Each ventilation grill or opening shall have a minimum free area of one square inch per 1 000 BTUH of the total input rating of the gas equipment in the confined space Figure...

Страница 13: ...alvemustbedisconnected fromsupplypipingsystemduringanypressuretestingofthatsystem at test pressures in excess of 1 2 psig 3 5kPa The appliance must be isolated from the gas supply piping system by clo...

Страница 14: ...the burner pressure which should be checked at the pressure test point Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Use test point A clos...

Страница 15: ...the mantel of your fireplace This is a fire hazard Figure 11 No greeting cards stockings or ornamentation of any type should beplacedonorattachedtothefireplace Thisisaheatingappliance The flow of hea...

Страница 16: ...surround panel assembly slightly until the bot tom return flange top panel is positioned over the top flange on the insert This secures the surround panel assembly to the insert without screws Traditi...

Страница 17: ...FINISHING THE FIREPLACE INSERT NEVER OBSTRUCT OR MODIFY THE AIR INLET OUTLET LOUVERS ON THE FIREPLACE IN SERT IN ANY MANNER NOTE INSTALL SURROUND PANELS SO THAT THE TOP PANEL RETURN FLANGE SLIDE S OV...

Страница 18: ...r to shut off automatically Note The blower shut off times will vary on blower speed and BTU input level setting control by adjustment of the HI LO knob located on the gas valve Blower removal instruc...

Страница 19: ...on burner pan 4 Compare the completed log installation with the appropriate photo from page 20 Review previous steps to make any necessary adjustments 5 Log placement is completed Attention Do not use...

Страница 20: ...26497 1 0310 Page 20 Do not cover any large rear ports with loose material glowing embers VFP20IN EMBER PLACEMENT PHOTOS...

Страница 21: ...log 5 Compare the completed log installation with the photo on page 22 Review previous steps to make any necessary adjustments 6 Log placement is completed 7 Attach log placement plate to cable holdin...

Страница 22: ...0 Page 22 Photo 1 Photo 2 Photo 3 Photo 4 Do not cover any large rear ports with loose material glowing embers Do not cover any large front ports with loose material glowing embers VFP28IN EMBER PLACE...

Страница 23: ...ion or gas flow to the appliance is shut off the pilot cannot be relighted until the safety magnet is de energized approximately 60 seconds There will be an audible click when the safety magnet in the...

Страница 24: ...LOT to OFF unless knob is pushed in slightly Do not force 6 Wait ten 10 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety informa ti...

Страница 25: ...ontrol knob slightly and turn clockwise to OFF 6 Wait ten 10 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If...

Страница 26: ...t 2 3 hours with the burner at the highest setting Provide maximum ventilation by opening windows or doors to allow odors to dissipate Any odors remaining after this initial break in will be slight an...

Страница 27: ...ll cause the thermocouple to cool When the thermocouple cools the heater will shut down MILLIVOLT PILOT Correct Pilot Flame Pattern Figure 22 Incorrect Pilot Flame Pattern Figure 23 If pilot flame pat...

Страница 28: ...the remote receiver must be placed to the right of the gas valve Install remote control receiver behind bottom louver Refer to remote control installation and operating instructions for more details o...

Страница 29: ...rrect Replace gas regulator 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enoug...

Страница 30: ...OL VFP20IN23L 10 P265 ORIFICE 42 NAT 10 P182 ORIFICE 53 LPG 29 R5171 PILOT NAT 29 R5170 PILOT LPG 30 R2479 REGULATOR 6 0 W C NAT 30 R2480 REGULATOR 10 0 W C LPG 31 P239 NIPPLE 3 8 NPT X 1 1 2 32 26012...

Страница 31: ...10 Page 31 3 9 14 4 2 3 6 1 8 10 11 12 13 15 MILLIVOLT VALVE ASSEMBLY HYDRAULIC VALVE ASSEMBLY 40 37 38 36 7 14 39 16 5 7 17 18 19 20 21 22 23 24 25 26 27 27 25 16 17 29 30 31 32 33 34 35 28 VFP20IN P...

Страница 32: ...Y 23 26161 VALVE BRACKET 26 R2423 CONNECTOR MALE 39 24925 BLOWER SUB ASSEMBLY WITH MOUNTING PLATE PAD 40 18879 RHEOSTAT ASSEMBLY SPEED CONTROL 41 R7649 FAN CONTROL 42 R2204 CORD SET 43 R7912 WIRE HARN...

Страница 33: ...0 Page 33 VFP28IN PARTS VIEW 5 3 4 6 3 1 2 7 8 9 10 11 12 13 14 15 16 17 18 22 24 23 25 26 27 28 29 19 20 31 32 33 34 35 36 30 37 MILLIVOLT VALVE ASSEMBLY HYDRAULIC VALVE ASSEMBLY 38 43 40 41 39 7 21...

Страница 34: ...cription VFP28IN LOG SET 1 R8301 REAR LOG 2 R8299 LEFT FRONT LOG 3 R8300 RIGHT FRONT LOG 4 R8302 Y BRANCH LOGS PARTS LISTS PARTS VIEWS Use Only Manufacturer s Replacement Parts Use of Any Other Parts...

Страница 35: ...rmation beyond what your dealer can furnish contact Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finis...

Страница 36: ...m Parts Heater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites...

Страница 37: ...26497 1 0310 Page 37 SERVICE NOTES...

Страница 38: ...26497 1 0310 Page 38 SERVICE NOTES...

Страница 39: ...26497 1 0310 Page 39 SERVICE NOTES...

Страница 40: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: