27525-2-0411
Page 12
Minimum Wall and Ceiling Clearances
36”
(91.44
cm)
2” (5.08
cm)
Figure 8
This fireplace can be installed with zero (0") clearance to
combustible material.
When facing the front of the appliance the minimum clearances to
combustible construction (material) are the following:
1. Clearances from the right side or left side of the fireplace opening
to any combustible wall or material should not be less than 2
inches.
2. Clearances from the top of the fireplace opening to the ceiling
should not be less than 36 inches.
Mantel Clearances for Built-in Installation
Figure 9
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard.
HEAT
FLOW
Figure 10
No greeting cards, stockings or ornamentation of any type should be
placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.
Figure 11
CLEARANCES
COMBUSTIBLE MATERIAL
COMBUSTIBLES
ALLOWED
4”
(10.2cm)
5 ½”
(14.0cm)
2 ½”
(63.0cm)
4 3/4”
(12.1cm)
6”
(15.2cm)
8 3/4”
(22.2cm)
8”
(20.3cm)
9 ½”
(24.1cm)
10”
(25.4cm)
10 1/4”
(26.0cm)
12”
(30.5cm)
11”
(27.9cm)
TOP OF FRAME
0
MANTEL