background image

30816-7-0814

Page 32

INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING

2

Main burner lights

when the pilot only

should light.

Pilot holds the flame?.

Main burner ignites?

Main burner remains

ON

1.

Replace DFC board.

2.

Replace the gas valve.

1.

Verify the pilot flame fully engulfs the tip of the sense electrode. If not replace the pilot

assembly.

2.

Replace the pilot assembly.

3.

Carefully clean the electrical connections of the sense cable, and the DFC board sense

cable connection.

4.

Replace the sense cable, or the cable-sense electrode assembly, or the pilot assembly.

5.

Verify the pilot is properly grounded.

6.

Replace the pilot orifice with a new orifice of correct size, and type, or replace the pilot

assembly.

7.

If pilot flow adjuster screw is not sealed, correct it.

1.

Verify the electrical connections’ integrity and make sure they are in accordance with the

relevant system wiring diagram. If necessary replace the wire harness.

2.

Check if the optional remote transmitter is in “thermostat” or “on” mode and verifyt there is a

call for heat (f using a thermostat remote). Adjust the setting for heat.

3.

Verify that the pilot hood is properly fitted and a pilot flame is directed to properly ignite the

main appliance burner.

4.

Replace the main burner orifice with a new orifice of correct size and type, or replace the

pilot assembly. Under all circumstances follow the service instructions.

5.

Remove the provided wiring harnesses from EV2 of gas valve (red base), and verify voltage

at ignition between the EV1 terminal and the ground connection on the valve body.

5.1

If the voltage is greater than 0 then Replace Valve.

5.2

Or Replace DFC.

6.

Check the pressure at the outlet pressure test point out according to the manufacturer’s

instruction. If not in accordance, replace the gas valve.

1.

Verify the electrical connections’ integrity and make sure they are in accordance with the

relevant system wiring diagram. If necessary replace the wire harness.

2.

Check the pressure at the outlet pressure test point out according the manufacturer’s

instruction. If not in accordance replace the gas valve.

3.

With the system in the OFF position, connect the voltmeter between the EV2 terminal

(green base) on the valve, and the ground on the valve body.

Turn the system ON, let pilot light, and observe the following voltage sequence: once the pilot

flame is proved, the voltage on EV2 should spike to approx. 5 VdC for approx. 2 sec and then

drop to approx. 0.6 VdC continuously.

3.1

If the sequence is respected, replace the gas valve.

3.2

If the sequence is not respected, replace the DFC board.

YES

YES

YES

NO

NO

NO

NO

Main burner

modulates

properly?

1.

Replace the main burner orifice with a new orifice of correct size (partial blockage possible).

Verify that the main burner flame modulates. If it does not modulate replace the gas valve.

2.

Verify that the gas valve outlet pressure limits are in accordance with the manufacturer

specifications. If not replace the gas valve.

3.

Verify the flame changes while rotating the HI/LO knob on the front of the gas valve. If there

is no change replace the gas valve.

FOR MANUAL HI/LO VERSION

Содержание VFD26 Series

Страница 1: ...do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department I...

Страница 2: ...10 000 BTU MILLIVOLT LIGHTING INSTRUCTIONS 19 MILLIVOLT LIGHTING INSTRUCTIONS 20 INTERMITTENT PILOT LIGHTING INSTRUCTIONS 21 HYDRAULIC THERMOSTAT LIGHTING INSTRUCTIONS 22 PILOT FLAME CHARACTERISTICS...

Страница 3: ...are necessary to avoid potential problems with sooting Sooting resulting from improper installation or operation can settle on surfaces outside the fireplace See instructions for proper installation...

Страница 4: ...this occurs some new internal rusting could occur If the valve is left open then treat the container as a new tank Always be sure your container is under vapor pressure by turning it off at the conta...

Страница 5: ...t in sooting and property damage Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied...

Страница 6: ...shown in Figure 2 for corner rough opening Be sure to provide gas line for fireplace and electrical power for optional blower assembly 1 Attach two nailing flanges to firebox sides with two 10 x 1 2 s...

Страница 7: ...NE OPENING JUNCTION BOX ASSEMBLY GAS LINE OPENING J I K B C G A D E Figure 4 VFD26 Series Dimensions Index Letter Dimension A 30 1 4 768mm B 30 762mm C 13 1 8 333mm D 18 1 8 460mm E 26 660mm G 25 635m...

Страница 8: ...rmostat FREC Electric Remote Control FWS 1 Wall Switch TMV Wall Thermostat Millivolt Reed Switch TRW Wireless Remote Wall Thermostat Water vapor is a by product of gas combustion An unvented room heat...

Страница 9: ...are confined spaces Furnaces installed in a confined space which supply heated air to areas outside the space must draw return air from outside the space through tightly sealed return air ducts A conf...

Страница 10: ...iling and one with 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces In most cases for direct communication with...

Страница 11: ...Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector cannot exceed three feet in l...

Страница 12: ...the top of the fireplace opening to the ceiling should not be less than 36 inches Mantel Clearances for Built in Installation Figure 9 Do not attach combustible material to the mantel of your firepla...

Страница 13: ...Remove shrink wrap and logs from fireplace 6 Place back base and fireplace in desired location 7 Connect gas line and electrical wiring at this time in accor dance with local codes ELECTRICAL CONNECT...

Страница 14: ...ogs per the Log Placement Instructions See Page 16 14 Install hood See Page 15 9 Attach mantel assembly to studs in the wall through the back brace using two 3 drywall screws provided 10 Slide front b...

Страница 15: ...holes in fireplace Attach top frame to fireplace Use two 8 x 1 2 Phillips screws for top frame 5 Replace bottom louver 6 Replace top louver 3 PIECE FRAME KIT SIDE TRIM HOOD INSTRUCTIONS 1 Remove uppe...

Страница 16: ...his step is optional for VFD26FP3L10 log sets Place front twig 5 onto 1 log and flat area on 3 log The bottom of the front twig is to be placed behind the grate tang that is second from the left Atten...

Страница 17: ...etween the front and middle logs Rock wool should not be placed in the area of the pilot assembly Glowing embers rock wool can cover the burner in between the front and middle logs but very little is...

Страница 18: ...r location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Logs brush with soft bristle brush or vacuum with brush attachment Remove loose particles and dust fro...

Страница 19: ...tom louver assembly if applicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob...

Страница 20: ...f applicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned fro...

Страница 21: ...R YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a...

Страница 22: ...LIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7 Turn gas control knob counterc...

Страница 23: ...e incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down MILLIVOLT PILOT Correct Pilot Flame Pattern Figu...

Страница 24: ...he Oxygen Depletion Sensor as follows 1 Clean the ODS pilot by loosening nut B from the pilot tubing When this procedure is required grasp nut A with an open end wrench 2 Blow air pressure through the...

Страница 25: ...setting Cleaning and Maintenance Main Burner WARNING Turn off heater and let cool before cleaning CAUTION You must keep control areas burner and circulating air passageways of heater clean Inspect th...

Страница 26: ...urner assembly NOTICE Do not let remote control receiver come in contact with burner assembly On circulating vent free firebox install remote control receiver behind bottom louver Refer to remote cont...

Страница 27: ...f Gas regulator setting is not correct Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Cont...

Страница 28: ...ating season or in power outage periods it is recommended that the pilot remain in the CPI standing pilot mode to reduce cold start issues and or conserve battery backup power during a power outage 3...

Страница 29: ...ON Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation adjustment alte...

Страница 30: ...ore proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and that the batteries inside the receiver and or optional battery pack...

Страница 31: ...ire harness 4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness 2 I...

Страница 32: ...and verify voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure at...

Страница 33: ...ODE ANSI NFPA 70 LAT EST EDITION A factory installed junction box is located on the lower right side of the fireplace Wiring must be fed to the junction box and attached to the receptacle that is prov...

Страница 34: ...REGULATOR LPG 29 R2708 IGNITOR PIEZO VFD26F M P 30L N P 10 R3623 PILOT ASSEMBLY LPG 10 R3624 PILOT ASSEMBLY NAT 11 21590 PILOT BRACKET LPG 11 23106 PILOT BRACKET NAT 12 23449 PILOT SHIELD 14 R9022 BUR...

Страница 35: ...LEX WITH SHUT OFF VFD26F M P 70L10 N P 10 R11327 PILOT ASSEMBLY LPG 10 R11328 PILOT ASSEMBLY NAT 11 30703 PILOT BRACKET LPG 14 27426 BURNER TUBE 16 P214 ORIFICE NAT 16 P193 ORIFICE LPG 18 30704 BURNER...

Страница 36: ...MBL INTERMITTENT PILOT VALVE A Y SSEMBL VFD26F M P 2 3 VFD26F M P 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 22 20 21 18 23 24 25 26 30 41 42 43 44 45 1 1 1 THERMOSTATIC VALVE Y ASSEMBL 22 20 21 23 2...

Страница 37: ...The magnets on the bottom of speed control will sufficiently hold the speed control in place 13 Attach fan control bracket to upper right side of firebox with one 10 x 1 2 hex screw provided See Figu...

Страница 38: ...PEED CONTROL FAN SWITCH GROUND BLACK FAN WHITE BLACK SWITCH BRACKET FBBX Wiring Diagram FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUCTIONS FBB4 OPTIONAL VARIABLE SPEED BLOWER 1 18858 Blower Base 2 R7...

Страница 39: ...one side panel into firebox 5 Align clearance hole on brick panel bracket with screw hole in the left or right interior top of firebox Use two 10 x 1 2 screws to attach brick panel bracket to interior...

Страница 40: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 41: ...of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and op...

Страница 42: ...30816 7 0814 Page 42 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 43: ...30816 7 0814 Page 43 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 44: ...t Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Отзывы: