INSTALLATION INSTRUCTIONS

AND OWNER’S MANUAL

FOR USE ONLy WITh A LISTED gAS-FIRED UNvENTED 

DECORATIvE ROOM hEATER NOT TO ExCEED 40,000 

bTU/h.

 Do not build a wood fire.

 

IMPORTANT!  Read  these  instructions  carefully  before  in

-

stalling or operating this gas appliance. These instructions 

should be left with the homeowner for future reference.

WARNINg

Improper installation, adjustment, alteration, 

service or maintenance can cause injury or 

property damage. Refer to this manual. For 

assistance  or  additional  information,  con

-

sult  a  qualified  installer,  service  agency  or 

the gas supplier.

Do  not  attempt  to  modify  or  alter  the  construction  of  the 

firebox or its components. Any modification or alteration of 

construction may void the warranty of this firebox. Children 

and adults should be alerted to the hazards of high surface 

temperature and should stay away to avoid burns or clothing 

ignition. Young children should be carefully supervised when 

they are in the same room as the firebox.

Carefully review the instructions supplied with the decorative 

type unvented room heater for the minimum fireplace size 

requirement. Do not install a vent-free log set in this firebox, 

unless this firebox meets the minimum dimensions required 

for the installation.

SELECT vENT-FREE 

UNIvERSAL FIREbOxES

 

GAS-FIRED

UNIvERSAL FIREbOx 

FOR ALL vENT-FREE 

LOg SETS MODELS:

vFS32Fb0F-6
vFS36Fb0F-6

vFS36Fb2hF-6

vFS42Fb0F-6

vFS42Fb2hF-6

WARNINg

FIRE OR ExPLOSION hAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death or 

property damage.

—  Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance.

—  WhAT TO DO IF yOU SMELL gAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do 

not use any phone in your building.

•  Leave the building immediately.

•  Immediately call your gas supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

•  If you cannot reach your gas supplier, 

call the fire department.

—  Installation and service must be 

performed by a qualified installer, 

service agency or the gas supplier.

INSTALLER: 

Leave this manual with the appliance.

CONSUMER: 

Retain this manual for future reference.

ANSI Z21.91 

Ventless Fireplace 

Enclosures 

for Gas Fired 

Decorative Type 

Unvented Room 

Heaters

Содержание SELECT VFS32FB0F-6

Страница 1: ...ative type unvented room heater for the minimum fireplace size requirement Do not install a vent free log set in this firebox unless this firebox meets the minimum dimensions required for the installa...

Страница 2: ...e Connection 9 Optional Fresh Air Kit Installation Instructions 10 12 Optional FBB5 Single Speed Blower Installation Instructions 13 15 Junction Box Wiring Installation Instructions 16 Maintenance 16...

Страница 3: ...of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is operating...

Страница 4: ...earance from the front of the firebox Figure 4 Clearances to Combustibles CLEARANCES Sidewall Clearances The clearance from the inside of the firebox to perpendicular combustible side wall should not...

Страница 5: ...39010 0 1018 Page 5 This page intentionally left blank...

Страница 6: ...installed directly on carpeting tile or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point...

Страница 7: ...34 1 4 39 1 4 43 1 4 C 23 3 16 23 3 16 23 3 16 D 25 1 16 30 1 16 34 1 16 E F 31 36 40 G 31 5 8 31 5 8 31 5 8 H 2 2 2 I 33 5 8 33 5 8 33 5 8 J K 7 9 16 7 9 16 7 9 16 L 40 7 16 42 15 16 44 15 16 M 70 15...

Страница 8: ...less steel or hammered pewter hoods are desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosely attach two screws...

Страница 9: ...xes to reduce the supply tank pressure to a maximum of 14 inch w c This is in addition to the regulator fitted to the log set WARNING Connection directly to an unregulated propane tank can cause an ex...

Страница 10: ...e outside air to the firebox as desired It must be installed prior to or at the time of firebox installation to framing The Fresh Air kit must be installed prior to the installation of wallboard or ot...

Страница 11: ...mbly collar on the firebox with band clamps or screws installer supplied 3 Run the other end of the duct through the exterior wall cutout 4 From the outside of the building connect the duct to the col...

Страница 12: ...0 1018 Page 12 OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS 1 2 3 PARTS LIST INDEX NO PART NO DESCRIPTION 1 29259 Outside Air Vent Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer Hardware...

Страница 13: ...a qualified electrician See Figure 20 1 If installed turn OFF gas supply to firebox gas log 2 If applicable turn OFF electric supply to firebox CAUTION All wiring should be done by a qualified electri...

Страница 14: ...omplete the installation plug the power cord into the junc tion box receptacle at the right rear corner of the firebox outer wrap See Figure 24 Figure 24 11 If room permits the power cord can be locat...

Страница 15: ...e noise level increases it indi cates a dirty blower wheel Remove fan and clean blower wheels WARNING Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater...

Страница 16: ...the electrical connection make sure that main power supply is disconnected The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes wi...

Страница 17: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 18: ...R3491 R3491 COVER JUNCTION BOX 4 38973 38973 38973 BLOWER COVER PLATE QUANTITY 2 5 R7051 R7052 R7053 ROD SCREEN QUANTITY 2 6 39517 39518 39519 HOOD 7 R9292 R9292 R9292 HEARTH LEDGE RIGHT 8 R9293 R9293...

Страница 19: ...39010 0 1018 Page 19 PARTS VIEW...

Страница 20: ...V 1 Brick Liners Liner for Firebox Contact dealer for all available optional liner kits Fresh Air Kit Deluxe and Premium Fireboxes VFA2 Frame Kits 3 Piece Frame Kits Black Stainless Steel or Hammered...

Страница 21: ...ss Steel finishes Contact dealer for all avail able optional hood acces sories Decorative Door Kits Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for...

Страница 22: ...ctive workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated i...

Страница 23: ...39010 0 1018 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 24: ...mfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Отзывы: