31447-5-0214
Page 56
Brief Description of the Components
The gas valve is fitted with a manual HI/LO knob to allow for man
-
ual modulation of the gas outlet pressure to the appliance burner.
The controls are designed to be used with either LPG or Natural
Gas and can be converted by use of an OEM supplied conversion
kit.
The Digital Fireplace Control (DFC) is an automatic gas ignition
system based on a single microcontroller core. This control man-
ages all functions related to ignition, flame sensing and supervi
-
sion for atmospheric applications.
The DFC can be set to provide continuous or intermittent ignition
control sequences and flame monitoring with safety shutdown in
case of failure.
The DFC is set up as a stand alone (AC powered system with
battery back up. See Lighting Instructions on page 55 and Wiring
Diagram on page 54.
Troubleshooting
Before proceeding with the procedures in the following trouble-
shooting table, verify that the power supply (AC/DC adapter) is
present and that the batteries inside the receiver and/or optional
battery pack are fresh and installed with correct polarity.
Make sure all the connections between the wire harnesses and
system components are proper and positive.
Verify that the static inlet pressure meets the manufacturer’s rec-
ommended inlet pressure. If necessary adjust the line pressure
regulator.
If the recommended actions for the following troubleshooting chart
do not help to address the problem consider replacing wiring har-
nesses.
WARNING
:
Any actions performed on the gas valve must be performed
in accordance with this instruction manual. Likewise, any
actions performed on the DFC or other system components
must be done in accordance with the individual component
instructions.
Replacement of components must be performed in accor-
dance with this instructions manual.
INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING
Содержание P)-6
Страница 20: ...31447 5 0214 Page 20 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 37: ...31447 5 0214 Page 37 Figure 57 DVVK 4FV DIRECT VENT TERMINATION KIT continued...
Страница 46: ...31447 5 0214 Page 46 Figure 70 MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM...
Страница 66: ...31447 5 0214 Page 66 PARTS VIEW...
Страница 75: ...31447 5 0214 Page 75 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...