The firebox is designed to accept a 3/8-inch gas line for an approved 

ventless gas logset. Have the line installed by a qualified service 

person in accordance with all building codes. Consult local building 

codes to properly size the gas supply line leading to the 3/8-inch 

hook-up at the unit. The state of Massachusetts requires that a 

flexible appliance connector cannot exceed three feet in length.
gas access holes are provided on both sides of the firebox. 

See 

Figure 12

. Carefully remove the knockout in the refractory brick 

panel using a large standard screwdriver and hammer. First, place 

screwdriver in groove next to plug and pry sideways to pop out 

main plug. Then remove the remaining concrete in hole with gentle 

tapping with ball peen hammer and/or screwdriver. A masonry drill 

and bit may also be used to create a clean hole for the gas line to 

pass through. 

See Figure 13.

after the brick panel knockout is removed, the firebox wrap may 

have a round metal knockout that must be removed also. Use a 

screwdriver to punch out the metal knockout.

Check gas type. Use only the gas type indicated on the gas log 

set rating plate. If the gas listed on the plate is not your type of gas 

supply, DO NOT INSTALL. Contact your dealer for proper model.

always use an external regulator for all LP fireboxes to reduce the 

supply tank pressure to a maximum of 14" w.c. This is in addition 

to the regulator fitted to the log set.

WarnIng: ConneCTIon dIreCTLY To an UnregULaTed 
L.P. TanK Can CaUse eXPLosIon.

 

Install only a ANSI Z21.97.1/CSA 2.41 ventless log set into this 

firebox. 

Figure 12

GAS LINE CONNECTION

Figure 13

GAS ACCESS HOLES

Содержание OP32FB2MF-2

Страница 1: ...stallation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this...

Страница 2: ...Combustible Materials 6 Outer Firebox Dimensions 7 Inner Firebox Dimensions 8 Planning Installation 9 10 Firebox Framing and Installation 10 11 Gas Line Connection 12 Master Parts Distributor List 13...

Страница 3: ...to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION Do Not Operate...

Страница 4: ...on of sale not for purpose of resale from the manufacturer This appliance is only for use with the type of gas indicated on the rating plate WARNING Any change to this appliance or its controls can be...

Страница 5: ...of the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equ...

Страница 6: ...firebox models must use the hood supplied with the firebox If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 1 Figure 1 Mantel Clearances CLEARANCES Do n...

Страница 7: ...P36FB2MF OP42FBMF A 39 7 8 41 7 8 41 7 8 B 36 5 8 41 5 8 43 1 8 C 17 1 16 19 1 4 19 1 4 D 28 1 4 32 1 4 36 1 4 E 32 7 8 34 7 8 34 7 8 F 31 36 40 G 22 1 4 24 24 H 6 1 8 6 3 8 6 3 8 I 28 3 8 30 3 8 30 3...

Страница 8: ...8 INNER FIREBOX DIMENSIONS E B A C D TOP VIEW SIDE VIEW INDEX LETTER OP32FB2MF OP36FB2MF OP42FBMF A 29 1 8 34 1 8 38 1 8 B 23 5 8 27 5 8 31 5 8 C 12 7 8 15 5 16 15 5 16 D 17 5 16 18 3 4 18 3 4 E 20 9...

Страница 9: ...t Minimum ceiling height 92 inches Outdoor Firebox Enclosure Requirements Do not install appliance until all necessary provisions are made for combustion and ventilation air Consult the written instru...

Страница 10: ...as mortar or stone etching do not remove the protective PVC film from the stainless steel until after this application is complete Once the film has been removed we recommend that the appli ance be c...

Страница 11: ...e a pan head screw through the middle bracket and into the top stud 5 Locate the two non combustible boards and place them above the firebox as shown in Figure 11 Attach the non combustible board to t...

Страница 12: ...e in hole with gentle tapping with ball peen hammer and or screwdriver A masonry drill and bit may also be used to create a clean hole for the gas line to pass through See Figure 13 After the brick pa...

Страница 13: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 14: ...390 R10393 Liner Rear 7 27792 27792 27792 Liner Bracket Bottom 8 20447 20447 20447 Liner Bracket Top 9 29068 20234 20237 Hood 10 R11107 R11036 R11037 Curtain Rod 11 R11108 R10765 R10765 Curtain Screen...

Страница 15: ...32273 0 0713 Page 15 PARTS VIEW...

Страница 16: ...er The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kep...

Отзывы: