background image

OUTDOOR LINEAR 

GAS FIREPLACE 

MODELS:

OLL60FP12S(N,P)-2

OLL60SP12S(N,P)-2

INSTALLER: 

Leave this manual with the appliance.

CONSUMER: 

Retain this manual for future reference.

 

WARNING

For Outdoor Use Only.

 

WARNING

If the information in these instructions are 

not followed exactly, a fire or explosion may 

result causing property damage, personal 

injury or loss of life.

 

WARNING

If not installed, operated and maintained in 

accordance with the manufacturer's instructions, 

this product could expose you to substances in 

fuel or from fuel combustion which can cause 

death or serious illness.
Installation and service must be performed 

by a qualified installer, service agency or the 

gas supplier.

 

DANGER

FIRE OR EXPLOSION HAZARD

If you smell gas:

1.  Shut off gas to the appliance.

2. 

Extinguish any open flame.

3.  If odor continues, leave the area 

immediately.

4.  After leaving the area, call your gas 

supplier or fire department.

Failure to follow these instructions could 

result in fire or explosion, which could cause 

property damage, personal injury, or death.

 

WARNING

Improper installation, adjustment, alteration, 

service or maintenance can cause injury or 

property damage. Read the installation, operating 

and maintenance instructions thoroughly before 

installing or servicing this equipment.

 

WARNING

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.
An Propane-cylinder not connected for use 

shall not be stored in the vicinity of this or any 

other appliance.

DANGER

CARBON MONOXIDE HAZARD

This appliance can produce carbon monoxide 

which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space 

such as a camper, tent, car or home.

GAS-FIRED

INSTALLATION INSTRUCTIONS

AND OWNER’S MANUAL

Page 1

Содержание OLL60FP12SN-2

Страница 1: ...ame 3 If odor continues leave the area immediately 4 After leaving the area call your gas supplier or fire department Failure to follow these instructions could result in fire or explosion which could...

Страница 2: ...port cylinder where it would be exposed to high temperatures Relief valve may open allowing a large amount of flammable gas to escape When transporting keep cylinder secured in an upright position wit...

Страница 3: ...nance See page 28 Tools Needed 1 1 8 inch Allen Wrench 2 Adjustalbe wrenches with range of 1 inch for gas connection 2 Adjustable pipe wrenches 1 Phillips Screwdriver CARTON CONTENTS INDEX NO DESCRIPT...

Страница 4: ...e Materials 9 Clearances 9 10 Fireplace Dimensions 11 Planning Installation 12 14 Fireplace Framing And Installation 15 23 Lighting Instructions 24 Main Burner Flame Characteristics 25 Operation Instr...

Страница 5: ...Please leave these instructions with the owner for future reference This unit complies with ANSI Z21 97 CSA 2 41 for Outdoor Gas Fireplaces InstallationandrepairshouldbedonebyaQUALIFIEDSERVICE PERSON...

Страница 6: ...adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed...

Страница 7: ...lass Droplets Glacier Ice DG1SL 1 2 in Decorative Glass Droplets Sangria Luster Note Decorative Glass Droplets may be added on top of the crushed glass as an enhancement Decorative Glass Droplets must...

Страница 8: ...fore changing spud orifice size Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail registration card suppli...

Страница 9: ...19 3 16 21 5 8 24 10 Figure 2 Mantel Clearances Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 1 COMBUSTIBLE MATERIALS No greeting cards stockings or o...

Страница 10: ...ireplace opening 16 in of non combustible material is provided to allow for placement of wall joint in a cooler temperature zone NON COMBUSTIBLE WALL BOARD PROVIDED Framing Header Fireplace Opening 2...

Страница 11: ...The width of the firebox opening 60 60 F The interior depth of the firebox not shown 19 23 7 8 G The rear exterior width of the firebox not shown 60 60 K Height from the bottom of the box to the gas l...

Страница 12: ...inside of a residence NOTICE This fireplace is NOT equipped with an Oxygen Depletion Sensor ODS pilot Installation of the fireplace may be in an open area however it is recommended that this fireplace...

Страница 13: ...nstalled by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 1 2 in hook up at the unit The state of Ma...

Страница 14: ...local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 Latest Edition A factory installed junction box is located on the lower right side of the fireplace The jun...

Страница 15: ...ace Framing Before completing the framing and installing fireplace provide a path for water drainage out of the fireplace Determine if the optional accessory drain pan will be used See Page 12 If the...

Страница 16: ...f the control panel with a Phillips head screw driver See Figure 15 Figure 15 d Lift front of burner assembly and tilt upwards and toward the back of the fireplace Retrieve the two supports from insid...

Страница 17: ...use A connector for the junction box to accommodate 1 2 in conduit is supplied in the instruction envelope The fireplace receptacle must be connected to an external GFI protected outlet installed nea...

Страница 18: ...adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas li...

Страница 19: ...ve seal has been achieved It is also equipped with an excess flow device In order to attain full flow to the fireplace the valve must be in the off position when the cylinder valve is turned on WARNIN...

Страница 20: ...f the floor of the Propane Gas supply cylinder enclosure and the ground Cylinder valves shall be readily accessible for hand opera tion A door on the enclosure to gain access to the cylinder valves is...

Страница 21: ...r removed for service If the sticker is not on the glass panel the low E side of the glass can be determined by using a multimeter ohmmeter The low E coating will conduct electricity Set the meter to...

Страница 22: ...with screws into the frame and pre drill and counter sink 1 8 in diameter holes into the fireplace face Finish remain ing wall with weather proof wallboard NOTE Areas where the steel has been formed c...

Страница 23: ...een and burner enough media to cover approximately 10 square feet Ensure coverage is even and not thicker in places Some pieces of broken glass may be larger than others It is fine to use these pieces...

Страница 24: ...cover s must be removed before use Remove any debris including leaves and insects from the burner area and the bed of crushed glass 1 Before turning on the main gas supply press the ignitor button Ver...

Страница 25: ...the burner at the highest setting Any odors remaining after this initial break in will disappear with continued use Flames from the main burner should be visually out before the weather door is instal...

Страница 26: ...the LED Lights when not in use LED Mode Button Press the Mode Button to adjust LED light system from Automatic Color Changes to Individual Colors 1 Auto cycle Rapid 2 Auto cycle Gradual 3 Pause Auto...

Страница 27: ...tion Verify proper operation after servicing WIRING Figure 33 LED System Wiring Figure 34 Electronic Ignitor System Wiring R11931 YELLOW RED GREEN BLUE RED BLACK LED STRIP LED STRIP TRANSFORMER CONTRO...

Страница 28: ...n abrasive stainless steel cleaner immediately WARNING Do not use Ammonia based or abrasive cleaners on glass Do not attempt to clean glass when glass is hot PERIODIC CLEANING Refer to parts diagram f...

Страница 29: ...n and or replace thermocouple 6 Burner does not stay lit a Burnerorificeclogged Cleanburnerorreplacemainburner orifice b Inlet gas pressure is too low Contact qualified service person 7 If burning at...

Страница 30: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 31: ...Y SUPPLY 1 1 20 P271 FITTING ORIFICE 1 1 21 R10808 AIR SHUTTER STAINLESS 1 1 22 P279 ORIFICE 14 1 0 22 P256 ORIFICE 41 0 1 23 B101848 GAS CONTROL KNOB 1 1 24 R7195 CONNECTOR BRASS MALE 1 1 25 R11916 V...

Страница 32: ...41309 2 0620 Page 32 OLL60FP PARTS VIEW 5 4 5 17 16 14 15 4 27 26 25 24 23 19 10 10 12 21 20 18 3 7 8 9 6 28 29 22 30 32 31 11 1 34 35 35 37 38 36 13 2 39 33 33...

Страница 33: ...71 FITTING ORIFICE 1 1 21 R10808 AIR SHUTTER STAINLESS 1 1 22 P279 ORIFICE 14 1 0 22 P256 ORIFICE 41 0 1 23 B101848 GAS CONTROL KNOB 1 1 24 R7195 BRASS CONNECTOR MALE 1 1 25 R11916 VALVE PROPANE MANUA...

Страница 34: ...41309 2 0620 Page 34 OLL60SP PARTS VIEW...

Страница 35: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might...

Страница 36: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Страница 37: ...ne qui n est pas connect pour tre utilis ne devrait pas tre rang proximit de cet appareil ou tout autre appareil L installation et l entretien doivent tre ex cut s par un installateur qualifi une agen...

Страница 38: ...xpos e des temp ratures lev es La soupape de d charge pourrait s ouvrir et lib rer une grande quantit de gaz inflammable Lors du transport s curiser la bouteille enposition debout et s assurer que le...

Страница 39: ...ien de base Voir page 28 Outils requis 1 Cl Allen 1 8 po 2 Cl s ajustables avec jeu de 1 po pour connexion du gaz 2 Cl s de tuyau ajustables 1 Tournevis Phillips CONTENU DE L EMBALLAGE REP RE DESCRIPT...

Страница 40: ...S 9 D GAGEMENTS 9 10 DIMENSIONS DU FOYER 11 PLANIFIER L INSTALLATION 12 14 INSTALLATION DU FOYER 15 23 INSTRUCTIONS D ALLUMAGE 24 CARACT RISTIQUES DE LA FLAMME DU BR LEUR PRINCIPAL 25 INSTRUCTIONS D O...

Страница 41: ...lammables Installateur Veuillez laisser ces instructions avec le propri taire pour r f rence ult rieure Cette unit est conforme ANSI Z21 97 CSA 2 41 pour les foyers gaz ext rieurs L installation et le...

Страница 42: ...sent dans le gaz chapp peut tre absorb sur ou dans lesmurs lama onnerieetautresmat riauxoutissusdanslapi ce Ceci retire une partie de l odorisant du gaz r duisant l intensit de son odeur Le Gaz Propa...

Страница 43: ...ngria Luster Remarque Les gouttelettes d coratives en verre peuvent tre ajout es sur le dessus du verre pil pour enjoliver Les gouttelettes d coratives en verre doivent tre plac es sur la flamme du br...

Страница 44: ...e l injecteur orifice Instructions l installateur 1 L installateur doit laisser le manuel d instructions au propri taire apr s la pose 2 L installateur doit demander au propri taire de remplir et post...

Страница 45: ...e 2 d gagements pour manteau de foyer Ne pas attacher de mat riaux combustibles l tre de votre foyer Ceci est un risque d incendie Figure 1 MAT RIAUX COMBUSTIBLES Ne jamais poser ni accrocher de carte...

Страница 46: ...mat riau non combustible de 406 mm 16 po est fourni pour allouer le placement du joint du mur dans une zone de temp rature plus fra che 165 mm 6 1 2 po Q Ossature de la colonne Ouverture du foyer Ouv...

Страница 47: ...erture du foyer 60 60 F La profondeur int rieure du foyer non illustr e 19 23 7 8 G La largeur ext rieure arri re du foyer non illustr e 60 60 K Hauteur du bas du foyer l ouverture de la conduite de g...

Страница 48: ...PAS quip d un pilote d tecteur d appauvrissement de l oxyg ne ODS L installation de ce foyer peut tre dans un endroit ouvert toutefois il est recommand d installer ce foyer dans un endroit l abri des...

Страница 49: ...n b timent locaux pour installer une conduite d alimentation de gaz ad quate pour un raccordement de 1 2 po l appareil L tat du Massachusetts pr voit qu un connecteur de foyer flexible ne doit pas d p...

Страница 50: ...on locale ou en l absence de r glementation locale avec le code lectrique national ANSI NFPA 70 si une source lectrique externe est utilis e Une bo te de jonction est pos e d usine sur le c t inf rieu...

Страница 51: ...C 19 1 4 22 1 2 Figure 11 Ossature du foyer Avant de terminer l ossature et d installer le foyer fournir un chemin pour loigner l coulement d eau du foyer D terminer si le bac d coulement en option s...

Страница 52: ...es deux vis des coins avant du panneau de contr le avec un tournevis Phillips Voir figure 15 ENSEMBLE BR LEUR Figure 15 d Soulever le devant de l ensemble du br leur et incliner vers le haut et l arri...

Страница 53: ...e utilisation ext rieure Un connecteur pour bo te de jonction permettant de loger un conduit de 1 2 po est fourni dans l enveloppe des directives La prise du foyer doit tre raccord e une prise disjonc...

Страница 54: ...taller ou d placer le robinet Les p tes d tanch it utilis es sur les raccords filet s de conduites de gaz doivent r sister l action des gaz de p trole liqu fi s Les tuyaux de gaz doivent tre v rifi s...

Страница 55: ...e d bit Afin d obtenir un d bit plein au foyer la valve doit tre ferm e lorsque la valve du cylindre est ouverte AVERTISSEMENT Un incendie peut survenir si le tuyau d alimentation en gaz fait contact...

Страница 56: ...vront tre facilement accessibles pour l op ration main Une porte l ouverture plac e pour acc der aux soupapes des cylindres est acceptable condition qu elle ne se verrouille pas et puisse tre ouverte...

Страница 57: ...5 et reposer la porte de contr le et l axe d articulation central 4 D visser le bouton d allumage et installer la pile AA fournie dans l enveloppe d instruction avant de fermer la porte de contr le Vo...

Страница 58: ...cer des trous de 3 mm 1 8 po diam tre dans la fa ade du foyer Terminer le mur restant avec un panneau mural r sistant aux intemp ries Remarque Les zones o l acier a t form coins bords rabattus etc pou...

Страница 59: ...rtains morceaux de verre bris peuvent tre plus grands que d autres Ces morceaux peuvent tre utilis s mais pas sur le br leur ni autour de la flamme Voir figure 25 On peut ajouter des gouttelettes de v...

Страница 60: ...r Retirer tout d bris dont les feuilles et les insectes autour du br leur et du lit de verre pil 1 Avant d ouvrir l alimentation de gaz principale appuyer sur le bouton d allumage V rifier que l allum...

Страница 61: ...glage le plus lev Toute odeur restante apr s ce rodage initial dispara tra apr s une utilisation continue Les flammes du br leur principal doivent tre teintes avant d installer la porte contre les int...

Страница 62: ...qui ne sont pas utilis s Bouton de mode DEL Appuyer sur le bouton de mode pour ajuster le syst me d clairage des DEL pour passer de couleur automatique couleurs individuelles 1 Cycle Auto Rapide 2 Cyc...

Страница 63: ...ration d entretien C BLAGE LECTRODE BO TE DE L ALLUMEUR LECTRODE THERMOCOUPLE Figure 33 C blage du syst me DEL Figure 34 C blage du syst me allumeur lectronique R12435 JAUNE ROUGE VERTE BLEUE BANDE D...

Страница 64: ...qu elle est chaude NETTOYAGE P RIODIQUE Veuillez vous r f rer au diagramme de pi ces pour l emplacement des articles discut s ci dessous Ne pas utiliser de nettoyant liquide pour nettoyer n importe q...

Страница 65: ...acer le thermocouple 6 Le br leur ne reste pas allum a L orificedubr leurestbouch Nettoyerlebr leurouremplacez l orifice du br leur principal b La pression de gaz d entr e est trop faible Contacter un...

Страница 66: ...ndeur La preuve d d achat est requise pour les pi ces sous garantie Toutes les pi ces figurant dans la Nomenclature des pi ces comportent une R f rence Lors de la commande de pi ces voir d abord le Nu...

Страница 67: ...33258 ENSEMBLE DE TUBULURE 1 1 20 P271 RACCORD ORIFICE 1 1 21 R10808 OBTURATEUR D AIR INOXYDABLE 1 1 REP RE R F PI CE DESCRIPTION QT REQ Naturel Propane 22 P279 ORIFICE N 14 1 0 22 P256 ORIFICE N 41 0...

Страница 68: ...41309 2 0620 Page 32 OLL60FP VUE DES PI CES 5 4 5 17 16 14 15 4 27 26 25 24 23 19 10 10 12 21 20 18 3 7 8 9 6 28 29 22 30 32 31 11 1 34 35 35 37 38 36 13 2 39 33 33...

Страница 69: ...URE 1 1 20 P271 RACCORD ORIFICE 1 1 21 R10808 OBTURATEUR D AIR INOXYDABLE 1 1 REP RE R F PI CE DESCRIPTION QT REQ Naturel Propane 22 P279 ORIFICE N 14 1 0 22 P256 ORIFICE N 41 0 1 23 B101848 BOUTON DE...

Страница 70: ...41309 2 0620 Page 34 OLL60SP VUE DES PI CES...

Страница 71: ...n justificatif de paiement pour attester de la date d achat et tablir la p riode de garantie Un acc s imm diat l appareil pour le service Ce qui n est pas couvert Dommages r sultant de l utilisation d...

Страница 72: ...Empire Comfort Systems Inc Belleville Illinois Pour toute question g n rale concernant nos produits veuillez nous envoyer un courriel info empirecomfort com Pour toute question d entretien ou de r pa...