DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED
Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly.
IMPORTANT SAFETY INFORMATION
WARNING
1. “Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.”
2. “Children and adults should be alerted to the hazards
of high surface temperature and should stay away to
avoid burns or clothing ignition.”
3. “Young children should be carefully supervised when they
are in the same room as the appliance. Toddlers, young
children, and others may be susceptible to accidental
contact burns. A physical barrier is recommended if there
are at-risk individuals in the house. To restrict access to a
fireplace or stove, install an adjustable safety gate to keep
toddlers, young children, and other at-risk individuals out
of the room and away from hot surfaces.”
4. For appliances requiring a barrier, as determined under
Clause 5.15.4: “A barrier designed to reduce the risk of
burns from the hot viewing glass is provided with this
appliance and shall be installed for the protection of
children and other at-risk individuals.”
5. “If the barrier becomes damaged, the barrier shall
be replaced with the manufacturer’s barrier for this
appliance.”
6. “Clothing or other flammable material should not be
placed on or near the appliance.”
7. “Any safety screen, guard, or barrier removed for
servicing an appliance must be replaced prior to
operating the appliance” (see Clause 4.1.6).
8. “Installation and repair should be done by a qualified
service person. The appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning might be required due to
excessive lint from carpeting, bedding material, et cetera.
It is imperative that control compartments, burners, and
circulating air passageways of the appliance be kept
clean.”
9. The instructions for an appliance optionally for use
with glass doors (or equivalent) shall state that, “Only
doors certified with the appliance shall be used.”
10. The instructions for an appliance not intended for use
with glass doors (or equivalent) shall emphasize that
the appliance is not for use with glass doors.
11. Where applicable, provide a means by which the
consumer can identify the barrier, (such as graphic
representation, clear description, or reference marking).
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each appliance
connected to the venting system being placed into operation
could result in carbon monoxide poisoning or death.
The following steps shall be followed for each appliance
connected to the venting system being placed into operation,
while all other appliances connected to the venting system
are not in operation:
1. Seal any unused openings in the venting system.
2. Inspect the venting system for proper size and horizontal
pitch, as required in the
National Fuel Gas Code ANSI
Z223.1/NFPA 54
or
the National Gas and Propane
Installation Code
CSA B149.1 and these instructions.
Determine that there is no blockage or restriction,
leakage, corrosion and other deficiencies which could
cause an unsafe condition.
3. As far as practical, close all building doors and
windows and all doors between the space in which
the appliance(s) connected to the venting system are
located and other spaces of the building.
4. Close fireplace dampers.
5. Turn on clothes dryers and any appliance not connected
to the venting system. Turn on any exhaust fans, such
as range hoods and bathroom exhausts, so they are
operating at maximum speed. Do not operate a summer
exhaust fan.
6. Follow the lighting instructions. Place the appliance
being inspected into operation. Adjust the thermostat
so appliance is operating continuously.
7. Test for spillage from draft hood equipped appliances
at the draft hood relief opening after 5 minutes of main
burner operation. Use the flame of a match or candle.
8. If improper venting is observed during any of the
above tests, the venting system must be corrected
in accordance with
National Fuel Gas Code
, ANSI
Z223.1/NFPA and/or
National Gas and Propane
Installation Code
, CSA B149.1.
9. After it has been determined that each appliance
connected to the venting system properly vents when
tested as outlined above, return doors, windows,
exhaust fans, fireplace dampers and any other gas-fired
burning appliance to their previous conditions of use.
Содержание MILLIVOLT DVCP36SP30N
Страница 45: ...LOG PLACEMENT LSU24SPF 36092 11 0820 Page 45...
Страница 66: ...36092 11 0820 Page 66 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 67: ...36092 11 0820 Page 67 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING...
Страница 71: ...36092 11 0820 Page 71 This page intentionally left blank...