background image

39669-0-0618

Page 5

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO FIREPLACE

GAS SHUT-OFF VALVE

1.  STOP! Read the safety information above.

2.  Turn OFF electric power to the appliance.

3.  Remove front surround panel assembly or bottom louver if 

included.

4.  Turn gas shut-off counterclockwise 

 to “On” position.

5.  Wait ten minutes to clear out any gas. Then smell for gas, 

including near the floor. If you smell gas, STOP! Follow “B” in 

the safety information above on this page. If you do not smell 

gas, go to the next step.

6.  Turn ON electric power to the appliance.

7.  Find pilot - Follow metal tube from gas control. The pilot is 

behind the burner on the right side.

8.  Turn main flame to on. If the pilot does not light within 60 

seconds, stop and go to Step 5.

9.  Refer to remote control instructions for detailed information, 

control  features,  and  operation.  Note:  There  is  a  CPI/IPI 

switch that allows for a continuous standing pilot mode or an 

intermittent  pilot  mode.  See  appliance  manual  for  location 

of this switch. If the pilot or burner does not stay lit (in the 

standing pilot mode), stop and immediately call a qualified 

service technician or gas supplier.

10.  If the burner or pilot does not operate properly after several 

tries, turn the gas shut-off clockwise 

 to “OFF” and 

call your service technician or gas supplier.

11.  Replace the front surround assembly or close bottom louver 

assembly.

12.  Operation  of  the  gas  valve  is  controlled  by  a  manual  on/

off  switch  or  a  hand  held  remote  control.  Refer  to  remote 

instructions for detailed operation information.

INTERMITTENT PILOT LIGHTING INSTRUCTIONS (FP7 SERIES)

A.  This appliance has a pilot which can be lighted with the 

manual on/off switch, a remote control, or by switching the 

receiver switch to the “ON” position. When lighting the pilot, 

follow these instructions exactly.

B.  BEFORE LIGHTING smell all around the appliance area for 

gas. Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor.

 

WHAT TO DO IF YOU SMELL GAS 

Do not try to light any appliance. Do not touch any electrical 

switch. Do not use any phone in your building. Immediately 

call your gas supplier from a neighbor’s phone. Follow the 

gas supplier’s instructions. If you can not reach your gas 

supplier, call the fire department.

C.  Use only the remote control or manual remote receiver 

switch to operate the gas valve. Never use tools. If valve 

does not operate, don’t try to repair it, call a qualified ser

-

vice technician. Force or attempted repair may result in a 

fire or explosion.

D.  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control which has been under water.

1.  Turn off all electric power to the appliance if service is to be 

performed (if applicable).

2.  Gain access to control compartment. Remove surround 

panel assembly if necessary.

3.  Locate On/Off gas shut-off and turn clockwise to 

 

“OFF”. Do not force.

4.  Close bottom louver assembly, if included.

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing 

property damage, personal injury, or loss of life.

Содержание MILLIVOLT DVCD32FP30N-4

Страница 1: ...rtment Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases u...

Страница 2: ...levision Considerations Installing a television above a fireplace has become increasingly popular however the areas above any fireplace gets hot and most TV manufacturers recommend against placing their products near a heat source If you install a television above this fireplace insert Empire Comfort Systems accepts no responsibility for damage or injuries Follow the television manufacturers insta...

Страница 3: ... A Thisappliancehasapilotwhichmustbelightedbyhand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your bui...

Страница 4: ...r remote controls NOTE The gas control valve allows you to increase or decrease the height of the main burner flame The control valve has a pressure regulator with a knob as shown in Figure 2 Rotate the knob counterclockwise to HI to increase the flame height and clockwise to LO to decrease the flame height 3 When the heating season ends turn the REMOTE OFF ON switch to OFF and the control valve t...

Страница 5: ...ol Refer to remote instructions for detailed operation information INTERMITTENT PILOT LIGHTING INSTRUCTIONS FP7 SERIES A This appliance has a pilot which can be lighted with the manual on off switch a remote control or by switching the receiver switch to the ON position When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure t...

Страница 6: ...recommended that the pilot remain in the CPI standing pilot mode to reduce cold start issues and or conserve battery backup power during a power outage 3 The gas valve has inlet and outlet pressure taps as shown in Figure 3 Refer to page 13 for gas pressure requirements NOTICE The gas control has a manual HI LO flame adjustment knob regulator that allows you to increase or decrease the height of t...

Страница 7: ... gas shut off valve 2 Depending on the valve type the fireplace is equipped with refer to either pages 3 or 5 for details on shutting off gas to the fireplace 3 Turn off gas to fireplace using the external shut off valve See pages 3 or 5 4 If the fireplace includes a remote control remove the batter ies from the transmitter and battery backup Purchase fresh batteries before the start of the next h...

Страница 8: ...depending on the circumstances present General Glass Information WARNING Do not operate appliance with the glass front removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person Only glass approved for use by the manufacturer in fireplace may be used for replacement The glass replacement should be done by a licensed or qualified service person WARNI...

Страница 9: ...spection should match the information illustrated in the manual Inspect primary air openings for blockage Check the glass and gasket for proper seal Clean Glass with a suitable fireplace glass cleaner Abrasive cleaners must not be used Be careful not to scratch the glass when cleaning Check all latches or other door retention components for proper operation tension and relief mechanisms are free f...

Страница 10: ...nged contact To prevent injury alert people in your home especially children to the hazards of high surface temperatures and warn them to stay away from the fireplace Supervise children whenever the fireplace is hot Young children and others may be susceptible to accidental contract burns Have your dealer install a physical barrier if there are at risk individuals in your home To restrict access t...

Страница 11: ...ons Inspect log set decorative media for debris and damage Clean dust and debris from fireplace Clean dust and debris from valves and control Clean glass with fireplace glass cleaner Freshen glowing embers if needed Replace batteries in battery pack Replace batteries in transmitter and receiver if installed Inspect venting for damage or corrosion Inspect venting for damage or obstruction SERVICE T...

Страница 12: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air theremaybemoreodoratlowerlevels Alwaysbesensitive to the slightest gas odor If you detect any odor trea...

Страница 13: ...20 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating fireplace or equipment The sign shall read in print size no less than 1 2 inch in size GAS VENT DIRE...

Страница 14: ...on Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale canceled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper insta...

Страница 15: ...39669 0 0618 Page 15 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Страница 16: ...www empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer ...