Page 31
Installation and Operation Manual - Gateway 3500
ENGLISH
8.1.2 With Step Top Add On
15
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
16
FROM DOUBLE WALL PIPE
CONNECTOR
Canada
USA
Canada
USA
A
6" (152 mm)
6" (152 mm)
D
10 ¾" (273 mm)
10 ¾" (273 mm)
B
14" (356 mm)
14" (356 mm)
E
24
⅞
" (632 mm)
24
⅞
" (632 mm)
C
7" (178 mm)
7" (178 mm)
F
17 ¾" (451 mm)
17 ¾" (451 mm)
8.1.4 With Lowered Ceiling
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
16
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
11" (279 mm)
11" (279 mm)
D
15 ¾" (400 mm)
15 ¾" (400 mm)
B
16" (406 mm)
16" (406 mm)
E
26
⅞
" (683 mm)
26
⅞
" (683 mm)
C
10" (254 mm)
10" (254 mm)
F
20 ¾" (527 mm)
20 ¾" (527 mm)
L
72" (1,830 mm)
72" (1,830 mm)
8.1.5 With Heat Shield AC02710 or AC02762 and Lowered Ceiling
15
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
16
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
2 ½" (64 mm)
2 ½" (64 mm)
D
7 ¼" (184 mm)
7 ¼" (184 mm)
B
2 ½" (64 mm)
2 ½" (64 mm)
E
13
⅜
" (340 mm)
13
⅜
" (340 mm)
C
2 ½" (64 mm)
2 ½" (64 mm)
F
13 ¼" (337 mm)
13 ¼" (337 mm)
L
74" (1,880 mm)
74" (1,880 mm)
15
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.
16
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.