30329-0-0312
Page 12
DVX36 DVX42
"A"
40 7/8" 40 7/8"
"B"
39 3/8" 43 3/8"
"C" 19 7/8" 19 7/8"
Figure 13
Attention:
If a base or mantel is not used and the appliance is
installed directly on carpeting, tile or other combustible material
other than wood flooring, it shall be installed on a metal or wood
panel extending the full width and depth of the appliance. The
vertical dimension in Figure 13 must be adjusted when a metal or
wood panel is placed beneath the appliance.
Finishing (Figures 14 and 15)
Finish the walls with the material of your choice. Figure 4 on page 8
shows the minimum vertical and corresponding maximum horizontal
dimensions of mantels or other combustible projections above the
top front edge of the fireplace.
Only non-combustible materials may be used to cover the black
fireplace front.
Warning:
When finishing the fireplace never obstruct or modify
the air inlet/outlet louvers in any manner. Provide adequate
clearances around air openings into the combustion chamber.
Caution:
If the joints between the finished wall and the fireplace
surround (top and sides) are sealed, a 300°F minimum sealant
material must be used. These joints are not required to be sealed.
Only non-combustible material (using 300°F minimum adhesive if
needed), can be applied as facing to the fireplace surround.
Flush Mount Mantel Installation (Figure 12)
The fireplace must extend 3/4" beyond finished wall surface when
using a flush mount mantel. Refer to Figure 12 to locate nailing
flanges on fireplace sides. Mark and drill two (2) 1/8" holes into
fireplace side to mount each nailing flange. Use eight (8) 1/2" hex-
head screws supplied in hardware package to attach nailing flanges
to fireplace sides.
NAIL OR OTHER
SUITABLE FASTENER
Figure 12
Framing (Figure 13)
Fireplace framing can be built before or after the fireplace is set in
place. Framing should be positioned to accommodate wall covering
and fireplace facing material. The fireplace framing should be
constructed of 2 x 4 lumber or heavier. The framing headers may
rest on the fireplace standoffs. Refer to Figure 13 for minimum
framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMING METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
Framing dimension "A" includes a six inch clearance for
standoffs on firebox. After installing firebox into framing,
the finished wall surface must cover the six inch opening
above the firebox.
INSTALLATION (continued)