background image

21552-0-0506

Page 7

Vertical Flex Termination Kit

Item 

Number

Item Description

Repair Part No.

Quantity 

Supplied

1

4”/7” Vertical Termination Cap

MF100038

1

2

Roof Support Kit

MF100503

1

3

2 Ply Alum Flex 4” Diameter by 6 ft.

MF04ALA2F006

1

4

2 Ply Alum Flex 7” Diameter by 6 ft.

MF07ALA2F006

1

5

4”/7” x 48” Rigid Pipe Assembly

MF100554

1

6

Firestop Thimble Assembly

MF100124

1

7

Roof Flashing (0/12 to 6/12)

MF100091

1

8

7” Flex Adapter Collar with Gasket

MF100524

1

9

7” Storm Collar

MF100147

2

10

Spring Spacers

MF100548

5

N/S

Clamp 4” Diameter

MF100330

2

N/S

Clamp 7” Diameter

MF100534

2

N/S

#8 x 1/2” Self Drilling Screws

N/A

20

N/S

HT Silicone

N/A

1

N/S

#8 x 5/8” Self Drilling Screws

N/A

10

Содержание DVVK-4FV

Страница 1: ...ted before initial use and at least annually by a quali ed eld service person Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air ow In spect entir...

Страница 2: ...e Vertical Flex Termination Kit WARNING Ensure that the venting system exits the structure through the roof and does not terminate less than 12 inches 305mm above the roof WARNING Refer to your replac...

Страница 3: ...his opening must be large enough to provide a mini mum 1 air space clearance from the vertical vent pipe to any combustible framing 6 Install the Firestop Thimble assembly to the framed opening in the...

Страница 4: ...f cutout opening see step 5 Feed the ex vent end down through the roof opening and restop thimble assembly installed in step 4 14 Secure the roof support assembly to the roof sheathing with at least 4...

Страница 5: ...that may be used as an attic insulation shield The collar can be installed around the ex pipe or hard pipe just above the restop thimble This collar will act as a shield to prevent blown in sulation...

Страница 6: ...imble Ceiling Straps As Req d Venting Support With Gasket Clamps 7 Dia Adapter Collar 4 Dia Flue Connector Assembly Firestop Thimble Adjustable Storm Collar Use To Keep Keep Insulation Out Of Inlet Ve...

Страница 7: ...Ply Alum Flex 7 Diameter by 6 ft MF07ALA2F006 1 5 4 7 x 48 Rigid Pipe Assembly MF100554 1 6 Firestop Thimble Assembly MF100124 1 7 Roof Flashing 0 12 to 6 12 MF100091 1 8 7 Flex Adapter Collar with G...

Страница 8: ...21552 0 0506 Page 8 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Отзывы: