31629-20-0320
Page 11
Figure 7
NOTICE:
Island and Room Divider installation is possible as long as the horizontal portion of the vent system does not exceed 20 feet
with a minimum vertical run of 8 feet. See details in Venting Section.
When you install your Direct Vent Fireplace in Room divider or Flat on wall corner positions, a minimum of six inches clearance must be
maintained from the perpendicular wall and the front edge of the appliance.
LOCATING FIREPLACE
Содержание DVD32
Страница 21: ...31629 20 0320 Page 21 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN ...
Страница 41: ...31629 20 0320 Page 41 Figure 61 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES ...
Страница 52: ...31629 20 0320 Page 52 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Страница 53: ...31629 20 0320 Page 53 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Страница 59: ...31629 20 0320 Page 59 DVD36FP 3 5 7 PARTS VIEW ...
Страница 61: ...31629 20 0320 Page 61 DVD42FP 3 5 7 PARTS VIEW ...
Страница 63: ...31629 20 0320 Page 63 DVD48FP 3 5 7 PARTS VIEW ...