FOR YOUR SAFETY READ BEFORE LIGHTING

A.  This appliance must be lighted with the remote control. 

When lighting the pilot, follow these instructions exactly.

B.  BEFORE LIGHTING, smell around the appliance area for 

gas.  Be  sure  to  smell  next  to  the  floor  because  some 

gases are heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch.

•  Do not use any phone in your building.

•  Immediately  call  your  gas  supplier  from  a 

neighbor's  phone.  Follow  the  gas  supplier's 

instructions. If you can not reach your gas 

supplier, call the fire department.

C.  Use only the remote control to operate the valve. Never 

use tools. If valve does not operate, don't try to repair it, 

call  a  qualified  service  technician.  Force  or  attempted 

repair may result in a fire or explosion.

D.  Do not use this appliance if any part has been underwater. 

Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system 

and any gas control which has been underwater.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

1.  Turn off all electric power to the appliance if service is to 

be performed (if applicable).

2.  Locate On/Off gas shutoff knob and turn clockwise to 

 "OFF." Do not force.

LIGHTING INSTRUCTIONS

1.  STOP! Read the safety information above.

2.  Turn OFF electric power to the appliance.

3.  Turn gas shutoff knob counterclockwise 

 to 

"ON" position.

4.  Wait ten minutes to clear out any gas. Then smell for gas, 

including near the floor. If you smell gas, STOP! Follow 

"B" in the safety information above on this label. If you 

do not smell gas, go to the next step.

5.  Turn ON electric power to the appliance.

6.  Using the remote control, turn main flame to "ON." Refer 

to the Multifunction Remote Operating Instructions for 

more information. If the pilot does not light within 60 

seconds, stop and go back to Step 4.

7.  Refer to remote control instructions for detailed 

information, control features, and operation. Note: 

Refer to Multifunction Remote operating instructions 

for selection of  continuous standing pilot mode or 

intermittent pilot mode. If the pilot or burner does not stay 

lit (in the standing pilot mode), stop and immediately call 

a qualified service technician or gas supplier.

8.  If  the  burner  or  pilot  does  not  operate  properly  after 

several  tries,  turn  the  gas  shutoff  knob  clockwise 

 to "OFF" and call your service technician or 

gas supplier.

9.  Operation of the gas valve, blower, and/or optional light 

must be controlled by using the hand held remote control. 

Refer to remote instructions for detailed operation 

information.

IGNITOR

WARNING

 

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 

personal injury or loss of life.

Содержание DVCT36CBP95N-1

Страница 1: ...LOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediat...

Страница 2: ...the fireplace This is a heating appliance The flow of heat can ignite combustibles Figure 1 GENERIC MODEL SHOWN COMBUSTIBLE MATERIAL TABLE OF CONTENTS SECTION PAGE Multifunction Remote Operating Instructions 3 9 Lighting Instructions 10 Maintenance And Service 11 12 Important Safety Information 13 Safety Information For Users Of Propane Gas 14 Requirements For Massachusetts 15 Warranty Back Cover ...

Страница 3: ... operating the remote system or activating manual bypass of the remote system CAUTION PROPERTY DAMAGE HAZARD EXCESSIVE HEAT CAN CAUSE PROPERTY DAMAGE The appliance can stay lit for many hours Turn off the appliance if it is not going to be attended for any length of time Always place the Transmitter where children can not reach it Figure 2 Figure 3 NOTE This control system includes a Battery Back ...

Страница 4: ...with a paper clip and the IFC module will beep three times to indicate the IFC module is ready to synchronize with the transmitter within ten seconds See Figure 5 Figure 4 SWI BUTTON Figure 5 5 With the batteries already installed in the Transmitter push the On button The Receiver will beep four times to indicate the Transmitter s command is accepted and sets to the par ticular code of that Transm...

Страница 5: ...m the Receiver confirms reception of the command Remote Control Display Figure 9 Remote Flame Control The Proflame has six flame levels With the system on and the flame level at the maximum in the appliance pressing the Down Arrow Button once will reduce the flame height by one step until the flame is turned off The Up Arrow Button will increase the flame height each time it is pressed If the Up A...

Страница 6: ... Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Button until the word SMART appears to the right of the temperature bulb gr...

Страница 7: ...lit Flow To activate this function use the Mode Button Figure 3 to index to the SPLIT FLOW mode icon See Figures 22 and 23 Pressing the Up Arrow Button will activate the secondary burner Pressing the Down Arrow Button will turn the secondary burner off A single beep will confirm the reception of the command OFF Figure 22 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS OFF Figure 23 Remote Auxiliary Re...

Страница 8: ... to avoid unsupervised operation To activate this function press the MODE and UP Buttons at the same time See Figure 28 To deactivate this function press the MODE and UP Buttons at the same time OFF Figure 28 Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the num...

Страница 9: ... the wall control or remote control OFF for two or three seconds and then restoring a power supply back on The return of the system to normal operation must be checked under safe conditions by the user and or service personnel Using the Fireplace without a Remote Control The fireplace can be turned ON HI only and OFF with the wall switch The fireplace flame ON OFF is the only function that will op...

Страница 10: ... force LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Turn OFF electric power to the appliance 3 Turn gas shutoff knob counterclockwise to ON position 4 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you do not smell gas go to the next step 5 Turn ON electric power t...

Страница 11: ...nd at least annually Inspect the external vent cap on a regular basis to make sure no debris is interferes with the air flow Cleaning the Glass Clean the glass periodically We recommend gas fireplace glass cleaner During start up condensation forms on the inside of the glass causing lint dust and other airborne particles to cling to the glass Also initial paint curing may deposit a film on the gla...

Страница 12: ... GLASS LATCH 4 PLACES L A T C H LA T C H LA T C H Figure 31 Light Bulb s Replacement 1 Remove the following items barrier screen glass frame assembly This unit comes standard with two lights that are attached to the roof of the fireplace To access the light bulb you will remove the following items by removing four screws per light See Figure 32 metal bezel glass gasket NOTE Use gloves when handlin...

Страница 13: ...l an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces The vent cap located on the outside of your home will also become very hot Alert everyone adults and children to stay clear and avoid touching the vent cap Keep the area around the vent cap clear of combustibles including shrubs and trees Do not use this fireplace if...

Страница 14: ...d gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air theremaybemoreodoratlowerlevels Alwaysbesensitive to the slightest gas odor If you detect any odor tr...

Страница 15: ...20 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating fireplace or equipment The sign shall read in print size no less than 1 2 inch in size GAS VENT DIRE...

Страница 16: ...the instructions furnished with the appliance A bill of sale canceled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this appliance Travel diagnostic costs and freight charges on warranted parts to and from the factory...

Отзывы: