Installing Optional CIB3 Blower

1.  Loosen, but do not remove, four (4) hex-head screws located 

on the exterior, bottom of the appliance.

2.  Position the blower assembly at the rear of the appliance. The 

blower assembly has four (4) keyholes for attachment to the 

exterior, bottom of the appliance.

3.  Place the large diameter holes in the keyholes over and behind 

the four (4) hex-head screws that were loosened in Step 1. 

Push inward on the blower assembly to lock the keyholes into 

position behind the screws. Tighten four (4) hex-head screws to 

secure blower assembly to exterior, bottom of the appliance.

4.  Remove wire channel-left from appliance by removing (2)  

10 x 1/2" screws on left side of the appliance. Note: Some 

units require a new wire channel. If Rheostat mounting holes 

are missing from part removed from unit, discard wire channel 

removed from unit and continue installation with appropriate 

wire channel shipped with blower. See Figure 1.

5.  Route fan control wires through rectangular notch on wire 

channel - left.

6.  Attach 1/4" push-on terminal from blue wire on the fan control 

to the AUTO (top) tab on the switch.

7.  Attach  1/4"  push-on  terminal  from  black  wire  to  the  OFF 

(middle) tab on the switch.

8.  Attach 1/4" push-on terminal from white wire on the fan control 

to the ON (bottom) tab on the switch.

9.  Insert AUTO/OFF/ON switch into rectangular notch on  wire 

channel - left.

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

Figure 1

10.  Install rheostat through hole in wire channel and align small 

tab with small hole.

11.  Use an 11/16” wrench to tighten rheostat nut on stationary 

portion of knob stem of the rheostat. Note: Nut is self-tapping 

and can be started at an angle.

12.  Push rheostat knob onto knob stem until fully seated.

13.  Bend the fan control tab, located on the left side of the back 

of the unit, inward toward the unit. See Figure 1. Be sure tab 

is bent at least 90 degrees to allow fan control bracket to slide 

into slot. 

14.  Attach  fan  control  with  bracket  onto  rear  cover  with  

two (2) 10 x 1/2" screws provided in hardware package.

15.  Route wires from fan control and ON/OFF/REMOTE switch 

within wire channel.

16.  Attach wire channel to channel divider with two (2) 10 x 1/2" 

screws from Step 4.  

17.  Installation of optional CIB3 blower is completed.

Fan Control

The fan control is a non-adjustable automatic type The fan control 

will require between 5 and 10 minutes of main burner operation 

before the fan control "closes" and activates the blower.  The blower 

will  continue  to  run  between  5  and  10  minutes  after  the  main 

burner shuts off, before the fan control "opens" and deactivates 

the blower.

AUTO/OFF/ON SWITCH

BLOWER ASSEMBLY

FAN CONTROL

RHEOSTAT

KNOB

NUT

WIRE CHANNEL - LEFT

WIRE CHANNEL - LEFT

(VF) MODELS

(DV) MODELS

FAN CONTROL TAB