EmpirBus NXT DCM Скачать руководство пользователя страница 11

 

EmpirBus NXT DCM User manual Ver 1.53 

10/15 

8.

 

Product specifications 

See table 4.1 for model specification and hardware support 

Output 

Fuse setting 

Output minus (-) 

Output minus (-)

 

 

1, 5, 8, 10, 15, 18 A (15 and 18A not available on all models) 

2 channels 0,1A minus 

4 channels 0,5A minus, 3A max 20 sec (not available on all 

models) 

Digital input 

12V power peak/average: 

24V power peak/average: 

Over current protection limit for LED

 

 

170mA / 1mA (closed), <0,1mA (open) 

340mA / 2mA (closed), <0,1mA (open) 

20mA  

Analog input 

Volt  

Current  

Resistance

 

 

0–32V +/-1%  

4–20mA +/-1% (not available on all models) 

0–1500 ohm +/-5% 

Communication 

CAN-bus 

Wireless receiver

 

 

NMEA 2000 

EnOcean 

Power supply 

Maximum current 

Supply voltage

 

 

100A  

9-32VDC 

Connectors 

NMEA 2000 

Channels 

Power supply 

Antenna 

 

 

Micro 5pin M12 Male 

Molex MX150L 16 circuits 

M6 bolt 

SMA female 

Environment 

Ambient temperature 

Enclosure

 

 

-20 to +55 degrees Celsius 

Ingress Protection IP65, Polycarbonate

1

 

Physical data 

Size 

Weight

 

 

229 x 104 x 41 mm 

0,4 kg

 

Exposure to solvents and/or water above 60

°

C may cause cracking on polycarbonate. 

 

 

 

Содержание NXT DCM

Страница 1: ...EmpirBus NXT DCM User manual...

Страница 2: ...5 6 1 3 Digital input commonline 5 6 1 4 Analog input resistance 5 6 1 5 Analog input voltage 6 6 1 6 Analog input multi switch 6 6 2 Outputs 6 6 2 1 Digital output positive 6 6 2 2 Digital output hal...

Страница 3: ...dust or gas explosion or other potentially flammable products 3 Scope of Delivery If the DCM is equipped with an integrated wireless receiver a stub antenna is included in the box 4 Model Range and o...

Страница 4: ...s and inputs are connected via Molex MX150L connectors Only use correct crimp and extractor tools when assembling the connector Unused pins in the connector should be plugged with circuit plugs in ord...

Страница 5: ...e channels inputs outputs are on the upper row of pins and the lower row is minus See figure 6 1 The Molex MX150L connectors connector accepts cable dimensions up to 2 5 mm2 6 1 Inputs Any channel on...

Страница 6: ...nline channel needs to be connected to a channel that can switch to minus which is possible on channel 6 or 14 on all DCM models The value of the resistor R can be calculated using R Voltage supply LE...

Страница 7: ...source and the DCM must have common ground I e Both batteries must have common ground Input value x 15k 15k R measured value Example 12V system 12V x 15k 15k 10k 7 2V Example 24V system 24V x 15k 15k...

Страница 8: ...sign of the window wiper two different circuits are possible Most common is window wiper circuit 1 See figure 6 2 Any channel can be used for Ch X and Ch Y Channel 4 5 12 or 13 is used as high speed c...

Страница 9: ...channel to normal operation 1 Press the right arrow button SEL will be shown in the display 2 Use the right arrow button to step to the desired channel 3 Press and hold RESET AUTO for two seconds The...

Страница 10: ...se right arrow button to step to P10 for wireless receiver programming 3 Press MAN ON MAN OFF Once Display shows OAS 001 blinking Wireless channel 1 is selected 4 Use right arrow button to choose chan...

Страница 11: ...1mA closed 0 1mA open 340mA 2mA closed 0 1mA open 20mA Analog input Volt Current Resistance 0 32V 1 4 20mA 1 not available on all models 0 1500 ohm 5 Communication CAN bus Wireless receiver NMEA 2000...

Страница 12: ...1 53 9 Appedix A Model range Table 9 1 Model range All units are produced with a setup of options See description in figure 4 1 Any DCM can be delivered with a wireless receiver Models with 0 5A minu...

Страница 13: ...__________________________________________________________________________________ __________________________________________________________________________________ _________________________________...

Страница 14: ...with EC Directive EMC 2014 30 EU 2020108W are in conformity with EC Directive RED 2014 53 EU We also declare that the articles 2010101 2010102 2010103 2010104 2010105 2010403 2010505 2020106 2020107 2...

Страница 15: ...06 2020107 2020108 2020109 2020110 2020408 2020510 2061001 are in compliance with Directive 2011 65 EU on the restriction of the use of certain hazardous substances in mechanics electrical and electro...

Страница 16: ...15 15 EmpirBus NXT DCM User manual Ver 1 53 Garmin Sweden Technologies AB Spikv gen 1 SE 451 75 Uddevalla Sweden Support Phone 46 522 44 22 22 E mail support empirbus com Web www empirbus com...

Отзывы: