GAS SUPPLY REQUIREMENTS
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut
-off valve.
Securely tighten all gas connections.
does not exceed 14" (36 cm) water column.
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
re.
Observe all governing codes and ordinances.
IMPORTANT:
This installation must conform with all local codes and ordinances.
In the absence of local codes, installation must conform with American National
Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or CAN/CGA
B149.1
– latest edition.
IMPORTANT:
Leak testing of the range must be conducted according to the
manufacturers instructions.
TYPE OF GAS
Natural gas:
proper conversion, for use with LP gas.
•
This range is factory set for use with Natural gas. See “Gas Conversions”
section. The model/serial rating plate located on the right side oven door trim
has information on the types of gas that can be used. If the types of gas listed do
not include the type of gas available, check with the local gas supplier.
16