4) Product Storing and Installation
We recommend the device to be installed and serviced by the qualified technician!
The product must not be stored and installed:
•
in the place with excessive humidity
•
in the place with dropping or running water
•
in the place with high dust pollution, mechanical vibrations or impacts
•
in the place out of temperature limits specified in the section 2) Technical Specifications
•
close to heat sources (radiators or air ventilators, direct sunshine etc.)
•
in the reach of children.
Do not expose the apparatus to dripping or splashing. Use the aparatus only in moderate climates (not in
tropical climate).
Fix the product firmly on a wall or another hard and inflammable surface with screws and dowels.
The product shall be in no case held only by the connected cables.
The mains socket must be
The mains socket must be
placed near the product. The mains socket and plug must be easily available.
placed near the product. The mains socket and plug must be easily available.
•
Ensure the free space for the air circulation (space on sides and bellow the product should be at
least 10 cm
•
Do not cover the product (with curtains etc.)
•
Do not place any containers with liquids (vases, glasses etc.) or naked flame sources (lighted
candle etc.) on the product or near the product.
5) Product Connection
Connect the product in accordance with this manual and valid regulation in you country. Use high quality
75 Ω coaxial cable designed for satellite reception. The coaxial cables shall not be broken, the minimum
bending radius should be 5 cm. Mount the F connectors (screw, crimp or compress type) on the ends of
coaxial cables. Connect the F connectors into the F sockets of product and fasten them with an appropriate
force.
•
Connect F-sockets marked „A“ – „H“ with outputs of LNBs according to table:
F-socket of multiswitch Quattro-LNB Outputs
Quad-LNB Outputs
A / E
V/L or 12V/0kHz
any output
B / F
H/L or 18V/0kHz
any output
C / G
V/H or 12V/22kHz
any output
D / H
H/H or 18V/22kHz
any output
•
Connect F-socket marked „TERR IN“ to terr. antenna or amplifier
•
Connect F-sockets marked “1”, “2”, “3”, … to wall sockets
•
Connect connector marked with protective bonding symbol with protective bonding conductor
•
Connect the mains plug into the mains socket with voltage according to section 2)
Note:
If some of outputs are not used, it is appropriate to terminate them with 75 Ohm loads. If not
terminated, actual insertion loss figure may differ from given value.
6) Setting
The product has no setting options. Connected satellite receivers must be set to two-satellites reception
using DiSEqC “A” / “B” and “Universal LNB”.
2 of 4