background image

Page 12

XPR-2

Connections

A word about safety

The XPR-2 (and any very high powered audio amplifier) is capable of delivering large 

voltages and currents at its speaker terminals. If, while music is playing, the speaker 

terminals or speaker cables are inadvertently shorted to each other, to interconnect cables, 

or to ground, the XPR-2 can cause damage to associated equipment, and may even pose a 

risk of electric shock. 

•  Ensure that the XPR-2 is powered Off before changing any connections.
•  Ensure that speaker wires are tightly secured before turning the XPR-2 On.
•  Ensure that metal objects and stray wires do NOT come in contact with the speaker 

terminals (on the XPR-2 and on the speakers) while the XPR-2 is turned On.

•  Ensure that speaker wires aren’t frayed or damaged, and are well insulated

 

(avoid using boutique speaker cables with thin or fragile insulation).

Choosing speaker cables

While the XPR-2 doesn’t require special speaker cables, we strongly suggest that you 

use heavy-gauge cables with low resistance that are capable of carrying large amounts 

of current. Any standard cable of 10 gauge or heavier (lower gauge numbers are heavier) 

will work well. Avoid cables that fail to provide the electrical equivalent of a 12 gauge or 

heavier conductor. Using a cable that is too thin probably won’t cause damage, but it will 

significantly degrade the sound produced by your speakers (it will make the bass on some 

speakers sound muddy and poorly controlled).

Connecting speakers to your XPR-2

The XPR-2 provides heavy duty gold plated audiophile grade five way binding posts for 

connecting one speaker to each channel. 

•  Always turn off the amplifier before connecting or disconnecting speaker cables or 

signal source interconnects.

•  Always verify that your speaker cables are firmly attached and not shorted to each other 

or to any other cables before powering up your XPR-2.

•  Always use high-quality speaker wire of reasonable gauge (10 gauge or heavier).
•  Be careful to wire all speakers “in phase” (the plus/red terminal on each speaker to the 

plus/red terminal on your amp).

•  Try to use wires of equal length and gauge for both speakers in each pair. Use the same 

gauge and length for both fronts, or for both surrounds; don’t use a long 12 gauge wire 

for one speaker and a short 10 gauge wire for the other. 

•  If you use stranded cables, use care to avoid short circuits from stray strands touching.
•  Emotiva offers very high quality pre-made speaker cables at reasonable prices. 

 

You will find them in the Interconnects section of our website at www.emotiva.com.

!

Содержание XPR-2

Страница 1: ...XPR 2 Stereo Reference Power Amplifier User Manual XPR 2...

Страница 2: ...CK DO NOT REMOVE THE COVER FROM THE XPR 2 THERE ARE NO USER SERVICEABLE PARTS INSIDE THE UNIT REFER ALL SERVICE TO QUALIFIED SERVICE PERSONNEL WARNING DANGEROUS VOLTAGES MAY BE PRESENT AT THE SPEAKER...

Страница 3: ...IRCUIT BREAKER IN YOUR BREAKER PANEL TO OPEN WHICH INDICATES THAT THE XPR 2 IS ATTEMPTING TO DRAW MORE CURRENT THAN YOUR CIRCUIT CAN SAFELY SUPPLY IF THIS OCCURS DO NOT REPLACE THE BREAKER OR FUSE WIT...

Страница 4: ...al 4 Features 5 Unpacking 6 XPR 2 Front Panel 7 XPR 2 Rear Panel 9 Quick Start 11 Connections 12 Configuration and Operation 14 Care and Maintenance 15 Specifications 16 Troubleshooting 18 Emotiva Aud...

Страница 5: ...Page 2 XPR 2...

Страница 6: ...ring system and controls the acoustically transparent high speed protection circuitry Gold plated machined heavy duty input and output connectors ensure that signals are transferred with the utmost fi...

Страница 7: ...mplifier We suggest that you read through the entire manual we kept things as short and direct as possible Even if you re an expert user you will probably find some interesting information and useful...

Страница 8: ...al world speaker loads Attractive styling which harmonizes well with virtually any audio system or room decor The cool blue accent illumination and blue meter LEDs complement the high gloss black of t...

Страница 9: ...unpack it please contact Emotiva immediately Gently remove your XPR 2 from the packing carton and remove all wrappings and shipping material It is important to save the boxes and all packing material...

Страница 10: ...sen If a fault occurs on one or both channels of the XPR 2 the LED above the Standby button the Channel Status LEDs and the LED Bargraph Meter LEDs associated with the channel that is reporting the fa...

Страница 11: ...Meter Button Press to switch between LED and Accent Lighting modes 1 LED Bargraph Meters Status LEDs Accent Lighting 2 Status LEDs only 3 All lights and LEDs off 4 Status LEDs only 5 Status LEDs Accen...

Страница 12: ...ugs as well as standard banana plugs and bare wire 2 Trigger Input and Trigger Output The XPR 2 is switched On from Standby when a trigger signal is presented at the Trigger Input the XPR 2 returns to...

Страница 13: ...XPR 2 On and Off When this switch is off no controls operate the XPR 2 cannot be turned On from the front panel or trigger 7 IEC Power Cord Receptacle Accepts a standard IEC C19 C20 AC power cable an...

Страница 14: ...u choose a stand or shelf that can support the full weight of the XPR 2 safely Connect the XPR 2 to your signal source Connect the XPR 2 to a pair of 8 ohm or 4 ohm speakers using heavy gauge speaker...

Страница 15: ...fail to provide the electrical equivalent of a 12 gauge or heavier conductor Using a cable that is too thin probably won t cause damage but it will significantly degrade the sound produced by your sp...

Страница 16: ...aker cables whenever possible DO NOT connect a digital signal to the inputs of your XPR 2 or you may damage it or your speakers Connecting the Trigger Input and Trigger Output The Trigger Input accept...

Страница 17: ...r the sides of the front panel and the Status LEDs and LED Bargraph Meters The button cycles between full brightness and dim in four steps each time it is pressed Meter Button front panel push button...

Страница 18: ...ng sticky gets on the front panel or case of the XPA 2 it should be cleaned with a mild cleaning solution applied to a soft rag followed by wiping with a clean rag dampened with plain water and drying...

Страница 19: ...into 4 Ohms Rated Power Bandwidth at rated power 8 Ohm load 20 Hz to 20 kHz 0 1 dB Minimum Recommended Load Impedance each channel 4 Ohms which equals one 4 Ohm load or two paralleled 8 Ohm loads per...

Страница 20: ...15 VAC or 230 VAC 10 50 60 Hz auto switching Protection The XPR 2 is protected against excessive operating temperature shorted speaker connections ground faults and other common fault conditions If a...

Страница 21: ...h Meters Status LEDs and Accent Lights are lit The button cycles through All On Status LEDs only All Off Status LEDs only and Status LEDs plus Accent Lighting but not Meters each time it is pressed Pr...

Страница 22: ...clear the Fault condition If the fault remains look for a shorted speaker cable or damaged speaker Check your sources and source connections a bad interconnect DC on the input or an otherwise bad sou...

Страница 23: ...m if it is not made within the Term and if it is not made in strict compliance with the requirements of the How do you get service section What will Emotiva do Emotiva will at its option either i repa...

Страница 24: ...CSR with a description of your problem and the serial number of the product for which the warranty claim is being made 2 The CSR will provide you with a returned material authorization number RMA 3 Sh...

Страница 25: ...cables and audio interconnects that feature solid engineering premium build quality excellent performance and reasonable cost you will find them in the Interconnects section of our website at www emo...

Страница 26: ...accurate to the best of our knowledge at the time of publication In keeping with our policy of ongoing product improvement we reserve the right to make changes to the design and features of our produ...

Страница 27: ......

Страница 28: ......

Отзывы: