18 – outdoor humidity
19 – outdoor clothing index
20 – max/min indoor temperature and
humidity
21 – station batteries low
22 – indoor humidity trend
23 – indoor humidity
24 – indoor temperature trend
25 – indoor temperature
26 – summer time
27 – alarm no.1, 2 activation
28 – time
29 – DCF signal reception
Rear and Sides of the Weather Station (See Fig. 2)
1 – SNOOZE/LIGHT button
2 – hole for hanging
3 – battery compartment
4 – RESET button
5 – stand
6 – ALARM button
7 – AM/PM button
8 – AL 1 button
9 – AL 2 button
10 – MODE button
11 – + button
12 – – button
13 – CH button
Sensor Description (See Fig. 3)
A – LED of signal transmission from the
sensor
B – sensor screen
C – hole for hanging
D – battery cover
E – battery compartment
F – CH button (sensor channel number setting
– 1/2/3)
G – °C/°F button
H – wired temperature probe (1 m)
Attention
Only use 1.5 V alkaline batteries of the same type; do not use rechargeable 1.2 V batteries.
Lower voltage may cause both of the units to not function.
Getting Started
1. First insert batteries (3× 1.5 V AA) into the weather station, then into the wireless sensor (2×
1.5 V AAA). Make sure the polarity is correct when inserting the batteries to avoid damaging the
weather station or sensor.
2. Once batteries have been inserted into the weather station, the screen will briefly light up and
the pressure unit icon will start flashing – set it using the +/- buttons, confirm by pressing
SNOOZE/LIGHT.
3. The pressure value will start flashing – set it using the +/- buttons, confirm by pressing SNOOZE/
LIGHT.
4. The forecast icon will start flashing – set it using the +/- buttons and confirm by pressing
SNOOZE/LIGHT. The setting process will be automatically interrupted if you do not press any
button for 20 seconds.
5. The icon for wireless communication with sensor will start flashing, indicating that the
weather station is searching for signal from the outdoor sensor. Place the two units next to
each other. If outdoor temperature does not appear within 3 minutes, the weather station will
stop searching for signal, the icon for wireless communication with sensor will stop flashing and
outdoor temperature/humidity will be displayed as --.-. If signal from the sensor is not detected,
repeat the process from step 1.
We recommend placing the sensor on the north side of the house. The range of the sensor may
decrease substantially in areas with a large number of obstacles. The sensor is resistant to dripping
water; however, it should not be exposed to sustained rain. Do not place the sensor on metal objects
as these would reduce transmission range.
The sensor can be placed vertically or hung on a wall.
A sensor with a wired probe can be placed in 2 ways:
1. The sensor is located in a room and the wired probe is led to the outside through a gap in the
window. In that case, the sensor measures outdoor temperature and indoor humidity.
2. The sensor and the wired probe are located outside. In that case, the sensor measures outdoor
temperature and humidity.