emmeti U9132040 Скачать руководство пользователя страница 1

      

Make the electrical connections to the numbered 
terminals as shown in the wiring diagram above and 
as follows:  

- 2:  Live feed. 
- 3:  Switched live to heating or cooling load (see also 
 

’Heating / Cooling selection’ inside). 

- 4 and 5: telephone interface (optional) for remote 
   

control of the programmable thermostat.

- 6 and 7:  remote sensor (optional).

When the        symbol appears in the display, the two 
1.5V AA alkaline batteries must be replaced. 
Please make sure you have two new batteries ready 
before replacement as you have 2 minutes to change 
them which will ensure that the programmes you have 
set will be retained, as follows: 

TC

P

 C

D

1 B

I0 0M

B

 018383D

4 080

910 

LOAD 

TELEPHONE 

INTERFACE 

REMOTE 
SENSOR 

1. Open the front flap (see Fig. 2) and remove the old 

batteries with a small tool. 

2. Replace the batteries as shown in Fig. 2, ensuring 

the + sign on each battery is facing the right way 
and close the flap. 

:DUQLQJ LI \RX H[FHHG  PLQXWHV LQ FKDQJLQJ WKH
EDWWHULHV \RX PD\ QHHG WR UHSURJUDPPH WKH
WKHUPRVWDWILUVWXVLQJWKHUHVHWEXWWRQLQ)LJ

Power supply: 

2 x 1.5V= (AA type) alkaline  

Battery life: 

~ 1 year 

Regulation range: 
 

Comfort:  

10°C .. 30°C 

 

Reduced: 

10°C .. 30°C 

Temperature sampling:  Every approx. 3 minutes 
Differential: 

0.4°C (asymm.: ex. 20.0°C off 

 

19.6°C on heating mode 

 

20.0°C off 20.4°C on cooling 

 mode) 
Sensor type: 

NTC 100k ohm @ 25°C 

Accuracy: ±1°C 
Resolution: 
 

Readout: 0.1°C 

 

Set-point: 0.2°C 

Contacts rating: 

5 (1) A @ 250V~ SPST (N.O.) 

Protection grade: 

IP 30 

Operating temperature:  0°C .. 40°C 
Storage temperature:  -10°C .. +50°C 
Humidity limits: 

20% .. 80% RH 

 

(non condensing) 

Case:  Material: 

ABS V0 self-extinguishing 

 

Cover color:  Signal white RAL 9003 

 

Base color: 

Anthracite grey RAL 7016 

Max size: 

133 x 87 x 32 mm (W x H x D)

In view of the constant development of their products, the manufacturer reserves the right to change technical data and features without 

prior notice. The consumer is guaranteed against any lack of conformity in accordance with the European Directive 1999/44/EC as well as 

the manufacturer’s own warranty policy. The full text of the warranty is available on request from Emmeti UK Ltd.

4

 

 - cable mounted remote sensor, 1.5m lead 

 

 - cased remote sensor* 

 

 - 230V 2 channel GSM telephone interface** 

*  -  Must be connected in cable of at least 1.5mm

2

 cross-sectional area, not more than 25m in length. 

** -  The remote telephone interface connects to a telephone line and to the thermostat enabling the heating to 
    be switched on remotely by SMS message to a continuous comfort setting. 

      

TC

P

 C

D

1 B

I0 0M

B

 018383A

4 0809

10 



A

B

 



 ­€‚

Suitable for 230v ~ or 24v ~ operation with switching load up to 5 (1) 
amps. 
Large LCD display showing on-off periods and time/temperature 
with low-battery and operating mode symbols 
Choice of built-in daily, weekly or weekday/weekend programmes 

with up to 4 on-off time periods per day with manual override & 
holiday programme 

Casing in elegant white design with anthracite grey base 
Simple dial operation for comfort and economy temperature settings adjustable from 10°C to 30°C 
Accurate temperature control for maximum comfort - differential 0.4°C 
Optional remote sensors for use in bathroom applications 

Switchable between heating and cooling modes 

6 Tannery Yard - Witney Street - Burford 

Oxfordshire - OX18 4DW - UK 

Phone: 01993 824900 
Fax:      01993 824990 

Email: [email protected]  

Website: www.emmeti.co.uk

1

Содержание U9132040

Страница 1: ...day with manual override holiday programme Casing in elegant white design with anthracite grey base Simple dial operation for comfort and economy temperature settings adjustable from 10 C to 30 C Accurate temperature control for maximum comfort differential 0 4 C Optional remote sensors for use in bathroom applications Switchable between heating and cooling modes 6 Tannery Yard Witney Street Burfo...

Страница 2: ...ack to change and to confirm After the confirmation of the day combination with button a time period combination will flash on the display Using the forward back confirmation buttons one of 4 different combinations can be selected from 1 per day minimum to 4 per day maximum After confirming the selected time period s with the button the start and finish times can be changed using the forward back ...

Страница 3: ...s are shown in Fig 1 override the programme being used as follows 1 Pressing it once changes the temperature to the opposite one in use until the programme time period changes again For example if the temperature is at the reduced setting pressing the button once will change it to the comfort level When the next time period occurs the temperature will stay at the comfort level and go to the reduce...

Страница 4: ...duced 10 C 30 C Temperature sampling Every approx 3 minutes Differential 0 4 C asymm ex 20 0 C off 19 6 C on heating mode 20 0 C off 20 4 C on cooling mode Sensor type NTC 100k ohm 25 C Accuracy 1 C Resolution Readout 0 1 C Set point 0 2 C Contacts rating 5 1 A 250V SPST N O Protection grade IP 30 Operating temperature 0 C 40 C Storage temperature 10 C 50 C Humidity limits 20 80 RH non condensing ...

Отзывы: