17
GB
GB
1. COMPOSITION
1.2 Heating/cooling model with 3/4” distribution collectors (2-12 way, with or without domestic water lines).
9
3
6
12
7
8
5
2
4
11
11
10
9
1
For correct built-in installation, it’s recommended that the module
be installed maintaining a distance of 135 mm between the back
of the box and the wall.
CAUTION
135 mm
Filo muro
Flow
Return
a
4-way Motorized ball valve DN20 with by-pass passage
b
Ball valve DN20 with probe connection M10x1
c
Infill valve (set up for DN15 volumetric meters and energy meter instal-
lation)
d
Impurity collection filter DN20
e
Fill/discharge tap with adjustable fitting
f
Manual air-relief valve
g
3/4" Flow collector (2" 12 ways)
h
3/4" Return collector (2" 12 ways)
i
Ball valve DN20
j
Ball valve DN20 with 3rd by-pass way
k
Ball valve DN20 with integrated retaining cartridge DN20
l
Painted galvanised metal box with key-operated lock for 120 mm
partition wall
Main connections: 3/4” F
Collector branch connectors: 24x19, 50 mm center distance
Note:
The box thus assembled is suitable for connection on the left side of the
main pipelines of the centralized system.