8
1. DESCRIZIONE DEI COMPONENTI
IT
IT
GB
GB
Heating water storage for integrated systems
Dimensional data
Models
Rif.
u.m.
EB300-S15-AS50
EB500-S18-AS50
Ø without insulation
A
mm
500
650
Ø with insulation
B
mm
640
790
Height
C
mm
1630
1680
Height whit isolation
mm
1630
1680
Probe
D
Ø 10
mm
290
320
Lower heat exchanger inlet
E
1”
mm
440
470
Lower heat exchanger outlet
F
1”
mm
440
470
Solar group bracket
G
80x150
mm
640
670
Boiler return
H
3/4”
mm
890
920
Thermometer - Probe
I
1/2”
mm
1340
1370
Heat pump return
or alternative energy
L
1”1/2
mm
230
260
Low Temperature flow of Heat pump
or alternative energy
M
1”1/2
mm
785
815
Probe
N
Ø 10
mm
870
900
Boiler flow
O
3/4”
mm
890
920
High Temperature flow of Heat pump
or alternative energy
P
1”1/2
mm
1340
1370
Cold water inlet
Q
1” (*)
mm
Above
Above
Air bleed
R
1/2”
mm
Above
Above
Cold water inlet
S
1” (*)
mm
Above
Above
Floor heating return
T
1”1/2
mm
230
260
Heating return
U
1”1/2
mm
785
815
Electrical resistance
V
1”1/2
mm
1060
1090
Heating and floor heating flow
W
1”1/2
mm
1340
1370
Solar expansion vessel bracket
Z
80x150
mm
380
410
Boiler connection distance
A1
mm
125
125
Solar connection distance
B1
mm
100
100
(*)with dielectric joints
Q
F
C
I
H
G
E
D
L
T
Z
A
B
U
V
W
M
N
O
P
R S
A1
B1