CTTS RF Radiofrequency digital programmable thermostat User Manual
reading of the probe or in case of time loss.
In case of
probe error
, if the antifreeze function is not deactivated, the instrument
activates the load for 10 minutes every 4 hours. The display shows the writing
(UU
on
field
(7)
.
In case of
time loss
(because of depleted batteries or blackout of a duration higher
than the charge reserve) the instrument restarts from the off mode, adjusting on the
basis of the antifreeze temperature, if it hasn’t been deactivated before. Reset date/
time to go back to the normal operation (programs modifications and settings remain
memorized).
TIMINGS: WHAT THEY ARE
Timings allow to maintain the current operation (automatic, manual, off) for a certain
period (times or days) and once passed the programmable thermostat changes the
operating mode, as explained below.
The timed operations are the following:
Timed automatic
If in automatic status you set a timing, such off status will be maintained until the end
of the timing; operation will then switched to off mode.
Timed manual
If in manual status you set a timing, such off status will be maintained until the end of
the timing; operation will then switched to automatic mode.