EMKO ESM-1510 Скачать руководство пользователя страница 6

1.2 Ordering Information

All order information of ESM-1510 

Temperature Controller are given on the 
table at left. User may form appropriate 
device configuration from information and 
codes that at the table and convert it to the 
ordering codes.

Firstly, supply voltage then other 

specifications must be determined. Please 
fill the order code blanks according to your 
needs.

Please contact us, if your needs are 

out of the standards.

V

     Symbol means Vac, 

Z

   Symbol means Vdc,

Symbol means Vac/dc

c

6

1.3 Warranty

EMKO Elektronik warrants that the equipment delivered is free from defects in material and 
workmanship. This warranty is provided for a period of two years. The warranty period starts from 
the delivery date. This warranty is in force if duty and responsibilities which are determined in 
warranty document and instruction manual performs by the customer completely.

1.4 Maintenance

Repairs should only be performed by trained and specialized personnel. Cut power to the device 
before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of 
these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl 
alcohol or water to clean the external plastic case.

A BC D

E

FG HI

/

/

U

V

W

Z

/

/

0

00

2

0

0

1

Relay Output ( resistive load 5 A@250 V 

V

 , 1 NO + 1NC )

Output-1

E

Supply Voltage

A

Input Type

BC

Scale(°C)

ESM-1510

 

24 V 

V

 ( ± 15% ) 50/60 Hz 

 

3

115 V 

V

 ( ± 15% ) 50/60 Hz 

4

230 V 

V

 ( ± 15% ) 50/60 Hz 

5

10...30 V 

 

Z

8
9 Customer

2

SSR Driver Output (Maximum 28 mA,15 V 

Z

)

00

12

05

09

J, Fe CuNi IEC584.1(ITS90)

PTC (Note-1) 

-50°C

150°C

0°C

800°C

-19.9°C

99.9°C

PT 100, IEC751(ITS90)

10 K, NiCr Ni IEC584.1(ITS90)

-50°C

400°C

0°C

999°C

11 PT 100, IEC751(ITS90)

14

-50°C

400°C

PT 1000, IEC751(ITS90)

13

-19.9°C

99.9°C

PT 1000, IEC751(ITS90) 

15

PTC (Note-1) 

-19.9°C

99.9°C

Temp. Sensor which is given with ESM 1510

V

0

None

1

PTC-M6L40.K1.5 

(PTC Air Probe with 1.5 m silicon cable)

2

PTCS-M6L30.K1.5.1/8” 

(PTC Liquid Probe with 1.5 m silicon

                                               cable)

Customer

3

NTC-M5L20.K1.5 

(NTC Probe, thermoplastic moulded with 

                                   1.5 m cable for cooling application)

4

NTC-M6L50.K1.5 

(NTC Probe, stainless steel housing with

                                   1.5 m cable for cooling application)

9

Note-1 : If input type is selected PTC or NTC (BC = 12, 15, 18, 19 ),
Temperature sensor is given with the device. For this reason,
If input type is selected as PTC, sensor type (V = 0,1 or 2) or 
If input type is selected as NTC, sensor type (V = 0,3 or 4) must be 
declared in ordering information.

19

-19.9°C

99.9°C

-50°C

100°C

18

NTC (Note-1) 

NTC (Note-1) 

24 V 

W

 ( - 15%, + 10% ) 50/60 Hz 

2

Содержание ESM-1510

Страница 1: ...g or cooling function Selection of operation with hysteresis Adjustable temperature offset Set value low limit and set value high limit boundaries Relay or SSR driver output Operation selection of com...

Страница 2: ...xplained Operation Also in these sections there are warnings to prevent serious injury while doing the physical and electrical mounting or using the device Explanation of the symbols which are used in...

Страница 3: ...ECTION 3 6 GALVANIC ISOLATION TEST VALUES OF ESM 1510 TEMPERATURE CONTROLLER 3 7 OUTPUT CONNECTIONS 3 7 1 RELAY OUTPUT CONNECTION 3 7 2 SSR DRIVER OUTPUT CONNECTION 4 FRONT PANEL DEFINITION AND ACCESS...

Страница 4: ...e Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following specifications EN 61000 6 4 2007 EMC Generic Emission Standard for I...

Страница 5: ...controlling temperature They can be used in many applications with their On Off control form heating and cooling control form and easy use properties Some application fields which they are used are be...

Страница 6: ...device Use a cloth dampened in ethyl alcohol or water to clean the external plastic case A BC D E FG HI U V W Z 0 00 2 0 0 1 Relay Output resistive load 5 A 250 V V 1 NO 1NC Output 1 E Supply Voltage...

Страница 7: ...Keep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the uni...

Страница 8: ...1 General Description 8 Rail Lock Apparatus 35 mm 1 38 inch 86 mm 3 38 inch 2 3 4 1 5 9 6 7 8 SV P ESM 1510 SET C Temperature Controller 2 2 Front View and Dimensions of ESM 1510 Temperature Controlle...

Страница 9: ...erating Temperature 0 to 50 C Max Operating Humidity 90 Rh non condensing Altitude Up to 2000 m Operating Conditions Forbidden Conditions Corrosive atmosphere Explosive atmosphere Home applications Th...

Страница 10: ...1 Put into the unit upper side of the rail properly 2 Pull down the rail lock apparatus via a screw driver 3 Push the unit from the underside for mounting to the rail 2 5 Removing from the Rail c 1 2...

Страница 11: ...hese parameters must be set according to the system s needs Only qualified personnel and technicians should work on this equipment This equipment contains internal circuits with voltage dangerous to h...

Страница 12: ...injury c i i 230 V V 15 50 60 Hz 1 5 VA 115 V V 15 50 60 Hz 1 5 VA 24 V V 15 50 60 Hz 1 5 VA 10 30 V 1 5 W Z 2 3 4 1 5 6 7 SV P ESM 1510 SET C Temperature Controller TC NTC PTC PT 100 PT1000 OUTPUT 5A...

Страница 13: ...230V V Supply Voltage Input and Relay Output 1 2 L N 230 VV 15 50 60Hz 1 5VA P N ESM 1510 5 05 0 1 00 00 2 0 0 0 3 5 OUTPUT 4 NO NC C 5A 250V V Y ca J Type TC 0 to 800 C Scale P N ESM 1510 5 05 0 1 00...

Страница 14: ...use on the device So a power supply switch and a fuse must be added to the supply voltage input Power supply switch and fuse must be put to a place where user can reach easily Power supply switch must...

Страница 15: ...10M W i i Pay attention the cable colours of PTC probe while doing the PTC probe connection i i Connect the wires with the polarity as shown in the figure left Always use compensation wire correspond...

Страница 16: ...put 1 2 Ground 6 2000 V V 2000 V V 2000 V V 2000 V V 2000 V V For ESM 1510 5 500 V V For ESM 1510 3 Input resistance is greater than 10M W i i 6 7 3 5 3 PT 100 and PT 1000 Connection PT 1000 6 7 PT 10...

Страница 17: ...l Element SSR 4 Device L N 5 Fuses must be selected according to the application c c Max 15 V Z Max 28mA Fuses must be selected according to the application c Device 5 Load L N 3 Max 5A V T Fuse NC C...

Страница 18: ...umber Operation Screen is shown If there is an unexpected situation while opening the device power off the device and inform a qualified personnel c Note 1 SV P ESM 1510 SET C Temperature Controller S...

Страница 19: ...on screen is shown SV P SET C SV P SET C SV P SET C SV P SET C C 4 2 Changing and Saving Set Value Operation Screen SET Value Screen SET Value Screen Operation Screen SET value is can be adjusted from...

Страница 20: ...19 9 C 99 9 C Switch On Delay After Power On Parameter Default 0 When power is first applied to the device this time delay must be expired for activation of the compressor It can be adjusted from 0 to...

Страница 21: ...Time HSt HSt Time 2 If Operating Type Parameter Value 0 Heating i In ON OFF control algorithm temperature value is tried to keep equal to set value by opening or closing the last control element ON O...

Страница 22: ...SV P SET C SV P SET C SV P SET C 5 secs Operation Screen Programming Mode Entering Screen Password Entering Screen Password Entering Screen Enter Password with increment and decrement buttons Press S...

Страница 23: ...eriod in case of probe defect Compressor is inactive during this time period in case of probe defect SV P SET C Programming Mode Accessing Password SV P SET C Hysteresis Parameter If no operation is p...

Страница 24: ...Accessing Password 24 Ana al ma Ekran SV P SET C SV P SET C SV P SET C SV P SET C SV P SET C SV P SET C Histeresiz Set De eri Minimum Set De eri Maximum Proses Ofset Parametresi al ma ekli Se imi SV P...

Страница 25: ...to blink If programming mode entering password is different from 0 programming mode entering screen will be observed 5 secs Programming Mode Entering Screen Note 2 Parameters can be observed by pressi...

Страница 26: ...nimum Set Value Parameter Minimum Set Value Parameter is accessed by pressing increment button If set button is pressed next parameter is shown Minimum Set Value i Other Programming mode parameters ca...

Страница 27: ...gree II office or workplace none conductive pollution Operating Conditions Continuous Supply Voltage and Power 230 V V 15 50 60 Hz 1 5 VA 115 V V 15 50 60 Hz 1 5 VA 24 V V 15 50 60 Hz 1 5 VA 24 V W 15...

Страница 28: ...Phone 90 224 261 1900 Fax 90 224 261 1912 Repair and Maintenance Service Information Emko Elektronik Sanayi ve Ticaret A Demirta Organize Sanayi B lgesi Karanfil Sk No 6 16369 BURSA TURKEY Phone 90 22...

Отзывы: