- 3 Digits display

- NTC Input or,
  PTC Input or,
  J type thermocouple Input or,
  K type thermocouple Input or,
  2-Wire PT 100 Input or,
  2-Wire PT 1000 Input (It must be determined in order)
- ON/OFF temperature control
- Selectable heating or cooling function
- Selection of operation with hysteresis
- Adjustable temperature offset
- Set value low limit and set value high limit boundaries
- Relay or SSR driver output
- Operation selection of compressor operates continuously, stops   
  or operates periodically in case of probe defect
- Compressor protection delays
- Password protection for programming mode

Instruction Manual. ENG ESM-1510 02 V08 08/14

ESM-1510  DIN Rail  Mounting Type

Digital, ON / OFF Temperature Controller

Содержание ESM-1510

Страница 1: ...g or cooling function Selection of operation with hysteresis Adjustable temperature offset Set value low limit and set value high limit boundaries Relay or SSR driver output Operation selection of com...

Страница 2: ...xplained Operation Also in these sections there are warnings to prevent serious injury while doing the physical and electrical mounting or using the device Explanation of the symbols which are used in...

Страница 3: ...ECTION 3 6 GALVANIC ISOLATION TEST VALUES OF ESM 1510 TEMPERATURE CONTROLLER 3 7 OUTPUT CONNECTIONS 3 7 1 RELAY OUTPUT CONNECTION 3 7 2 SSR DRIVER OUTPUT CONNECTION 4 FRONT PANEL DEFINITION AND ACCESS...

Страница 4: ...e Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following specifications EN 61000 6 4 2007 EMC Generic Emission Standard for I...

Страница 5: ...controlling temperature They can be used in many applications with their On Off control form heating and cooling control form and easy use properties Some application fields which they are used are be...

Страница 6: ...device Use a cloth dampened in ethyl alcohol or water to clean the external plastic case A BC D E FG HI U V W Z 0 00 2 0 0 1 Relay Output resistive load 5 A 250 V V 1 NO 1NC Output 1 E Supply Voltage...

Страница 7: ...Keep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the uni...

Страница 8: ...1 General Description 8 Rail Lock Apparatus 35 mm 1 38 inch 86 mm 3 38 inch 2 3 4 1 5 9 6 7 8 SV P ESM 1510 SET C Temperature Controller 2 2 Front View and Dimensions of ESM 1510 Temperature Controlle...

Страница 9: ...erating Temperature 0 to 50 C Max Operating Humidity 90 Rh non condensing Altitude Up to 2000 m Operating Conditions Forbidden Conditions Corrosive atmosphere Explosive atmosphere Home applications Th...

Страница 10: ...1 Put into the unit upper side of the rail properly 2 Pull down the rail lock apparatus via a screw driver 3 Push the unit from the underside for mounting to the rail 2 5 Removing from the Rail c 1 2...

Страница 11: ...hese parameters must be set according to the system s needs Only qualified personnel and technicians should work on this equipment This equipment contains internal circuits with voltage dangerous to h...

Страница 12: ...injury c i i 230 V V 15 50 60 Hz 1 5 VA 115 V V 15 50 60 Hz 1 5 VA 24 V V 15 50 60 Hz 1 5 VA 10 30 V 1 5 W Z 2 3 4 1 5 6 7 SV P ESM 1510 SET C Temperature Controller TC NTC PTC PT 100 PT1000 OUTPUT 5A...

Страница 13: ...230V V Supply Voltage Input and Relay Output 1 2 L N 230 VV 15 50 60Hz 1 5VA P N ESM 1510 5 05 0 1 00 00 2 0 0 0 3 5 OUTPUT 4 NO NC C 5A 250V V Y ca J Type TC 0 to 800 C Scale P N ESM 1510 5 05 0 1 00...

Страница 14: ...use on the device So a power supply switch and a fuse must be added to the supply voltage input Power supply switch and fuse must be put to a place where user can reach easily Power supply switch must...

Страница 15: ...10M W i i Pay attention the cable colours of PTC probe while doing the PTC probe connection i i Connect the wires with the polarity as shown in the figure left Always use compensation wire correspond...

Страница 16: ...put 1 2 Ground 6 2000 V V 2000 V V 2000 V V 2000 V V 2000 V V For ESM 1510 5 500 V V For ESM 1510 3 Input resistance is greater than 10M W i i 6 7 3 5 3 PT 100 and PT 1000 Connection PT 1000 6 7 PT 10...

Страница 17: ...l Element SSR 4 Device L N 5 Fuses must be selected according to the application c c Max 15 V Z Max 28mA Fuses must be selected according to the application c Device 5 Load L N 3 Max 5A V T Fuse NC C...

Страница 18: ...umber Operation Screen is shown If there is an unexpected situation while opening the device power off the device and inform a qualified personnel c Note 1 SV P ESM 1510 SET C Temperature Controller S...

Страница 19: ...on screen is shown SV P SET C SV P SET C SV P SET C SV P SET C C 4 2 Changing and Saving Set Value Operation Screen SET Value Screen SET Value Screen Operation Screen SET value is can be adjusted from...

Страница 20: ...19 9 C 99 9 C Switch On Delay After Power On Parameter Default 0 When power is first applied to the device this time delay must be expired for activation of the compressor It can be adjusted from 0 to...

Страница 21: ...Time HSt HSt Time 2 If Operating Type Parameter Value 0 Heating i In ON OFF control algorithm temperature value is tried to keep equal to set value by opening or closing the last control element ON O...

Страница 22: ...SV P SET C SV P SET C SV P SET C 5 secs Operation Screen Programming Mode Entering Screen Password Entering Screen Password Entering Screen Enter Password with increment and decrement buttons Press S...

Страница 23: ...eriod in case of probe defect Compressor is inactive during this time period in case of probe defect SV P SET C Programming Mode Accessing Password SV P SET C Hysteresis Parameter If no operation is p...

Страница 24: ...Accessing Password 24 Ana al ma Ekran SV P SET C SV P SET C SV P SET C SV P SET C SV P SET C SV P SET C Histeresiz Set De eri Minimum Set De eri Maximum Proses Ofset Parametresi al ma ekli Se imi SV P...

Страница 25: ...to blink If programming mode entering password is different from 0 programming mode entering screen will be observed 5 secs Programming Mode Entering Screen Note 2 Parameters can be observed by pressi...

Страница 26: ...nimum Set Value Parameter Minimum Set Value Parameter is accessed by pressing increment button If set button is pressed next parameter is shown Minimum Set Value i Other Programming mode parameters ca...

Страница 27: ...gree II office or workplace none conductive pollution Operating Conditions Continuous Supply Voltage and Power 230 V V 15 50 60 Hz 1 5 VA 115 V V 15 50 60 Hz 1 5 VA 24 V V 15 50 60 Hz 1 5 VA 24 V W 15...

Страница 28: ...Phone 90 224 261 1900 Fax 90 224 261 1912 Repair and Maintenance Service Information Emko Elektronik Sanayi ve Ticaret A Demirta Organize Sanayi B lgesi Karanfil Sk No 6 16369 BURSA TURKEY Phone 90 22...

Отзывы: