Features and Components

3.  Connect the power adapter to the ionizer to turn it on.  

 

When the unit is first turned on, it conducts a self-test.  

 

The audible alarm will sound, and the status LED will 

 

cycle through orange and green.  The LED will remain 

 

green during normal operation.

A.  Ground Jack:

 Insert the banana plug end of the included 

ground cord to this jack.  Connect the ring terminal end of the 

cord to equipment ground.

B.  24VDC Power Jack:

 Connect the power adapter here to 

power the Mini ZVI 2.

C.  Fan Speed Switch:

 Slide the switch down to set the fan 

speed to LOW.  Slide the switch up to set the fan speed to 

HIGH.

D.  Balance Adjustment Potentiometer:

 Turn the 

potentiometer clockwise for positive adjustment.  Turn the 

potentiometer counter-clockwise for negative adjustment.

E.  Status LED: 

The LED will illuminate green when the 

ionizer runs normally.  It will illuminate orange and sound 

the buzzer should the ionizer experience circuit failure or its 

emitter pins become too dirty to operate effectively.

Installation

Place the unit at a desired location where that the airflow 

will not be restricted.  The Mini ZVI 2’s compact size and 

mountable stand allow it to be installed in confined spaces 

such as enviornment chambers and automated machinery.
Connect the ground cord to the ionizer’s ground jack.  Attach 

the ring terminal end of the ground cord to a ground point.  

The face plate screw of a grounded AC wall outlet may 

provide a convenient connection point.

Operation

1.  Set the fan speed switch to the LOW or HIGH position.  

 

Higher airflow will result in faster neutralization rates.

2.  Position the ionizer so that maximum airflow is directed

 

towards the items or area to be neutralized.