Specifications

Description:

Single-wire, bipolar, corona ionization system 

conforming to ANSI/ESD S20.20, tested per ANSI/ESD 

STM3.1 and ESD TR53

Charge Decay (Discharge Time):

±1000V to ±100V in 300 seconds or less (60 seconds 

typical) 

Input Voltage:

90VAC to 260VAC, 47 to 63Hz, 65 W

Input Connector:

IEC 60320-1 C-14

Open Circuit Output Voltage:

0 kVDC to 10 kVDC ±5%

Short Circuit Output Current:

200 μA MAX digitally controlled, additional current 

limitation via 100 megohm series resistor

Emitter Capacity:

300 per power supply (5,200 square foot area)

Emitter Control:

Fully programmable, 0-99.9 second ionization ON cycle 

for each polarity with selectable quiescent periods 

between cycles

Power Supply Indicators:

Power ON, alarm, positive and negative voltage output 

and neutral delay

Zone Sensors:

Independent, cylindrical detectors with BNC connectors, 

RG58 or equivalent cabling (provided)

Power Supply Weight:

30 lbs (14 kg)

Offset Voltage (Balance):

<±150V per ANSI/ESD S20.20-2007  

Calibration:

Semi-annual calibration recommended

Tablet PC Operating System:

Windows 10 Pro

IRIS Amendment

EMIT IRIS installation includes:
• Installation 

• Configuration 

• Calibration 
The performance of the EMIT IRIS – Intelligent Room 

Ionization System is directly related to uniform airflow 

throughout the area being ionized.  Minimum laminar 

airflow of 70 FPM and distance from emitter to test 

surface of 5' is necessary to enable the system to 

meet Offset Voltage (Balance) and Voltage Decay 

(Discharge Times) performance specifications.  In the 

event that minimum environment specifications cannot 

be met, some system modification may be required. In 

addition, some large objects (machines, etc.) may have 

a significant effect on the ionization performance in the 

vicinity of the objects.
Upon completion of IRIS Installation, IRIS will 

be calibrated to the required limits of ANSI/ESD 

S20.20-2007 with offset voltage of less than ±150V, 

as well as predetermined decay times agreed upon by 

both customer and EMIT tested per ESD TR53.  Any 

changes to the environment of the IRIS installation 

Scope of Work after the installation may require 

modifications and recalibration. This includes and is not 

limited to airflow changes to the environment, layout 

changes (including work benches and machinery). 

All ionizers require periodic maintenance, emitter pin 

cleaning, and recalibration. Associated costs are not 

included in the original purchase price. All testing and 

recalibration of the IRIS performed after installation will 

be quoted to the customer for parts and labor separately 

from the initial Quotation and Purchase Order.  

Содержание 50849

Страница 1: ...the clean room Item Description 50849 IRIS Power Supply 50879 IRIS Tablet PC with TEAM5 IRIS Client Software The EMIT IRIS Room Ionization System meets the ANSI ESD S20 20 2007 required limit less th...

Страница 2: ...ication lost between the IRIS Power Supply and IRIS Tablet PC E LCD Display Displays current output voltage F Power Switch Powers the Power Supply G Reset Switch Resets the Power Supply s alarm H IRIS...

Страница 3: ...ble ion production when in use Each IRIS Zone is independently controlled by TEAM5 IRIS Client Software TEAM5 IRIS Client Software logs all significant events to a database for ongoing analysis and fo...

Страница 4: ...supplies must be turned off before any maintenance procedures are taken The conduits and housings may be wiped clean using an all purpose cleaner make sure that all cleaners used are consistent with...

Страница 5: ...nfiguration Calibration The performance of the EMIT IRIS Intelligent Room Ionization System is directly related to uniform airflow throughout the area being ionized Minimum laminar airflow of 70 FPM a...

Страница 6: ...ESCO INDUSTRIES INC Employee Owned EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com Figure 10 IRIS Power Supply overall dimensions inches Figure 11 IRIS Power Supply mounting...

Страница 7: ...6 DESCO INDUSTRIES INC Employee Owned EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com Figure 12 IRIS Tablet PC overall dimensions inches Figure 13 IRIS Tablet PC mounting bra...

Страница 8: ...Page 8 of 9 2016 DESCO INDUSTRIES INC Employee Owned EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com Figure 14 Average room coverage of 5 200 square feet 52 0 100 0 Coverage...

Страница 9: ...Website DescoEMIT com Limited Warranty Warranty Exclusions Limit of Liability and RMA Request Instructions See the EMIT Warranty http EMIT DescoIndustries com Warranty aspx Figure 15 IRIS room layout...

Отзывы: