background image

8

©2020 EMist

®

 is a registered trademark of SanoTech 360, LLC. All rights reserved.  

EMist-00054-20 - Ver. 072220

4. Spray Application 

TIP:

 

IF THE APPLICATOR BECOMES WET OR BEGINS 

TO DRIP, YOU ARE MOVING TOO SLOW OVER THE 
SURFACE TARGET AREA AND NEED TO SPEED UP THE 
APPLICATION PROCESS. DO NOT OVER-SATURATE 
THE SURFACE. IF YOU SEE RUNS OR PUDDLES YOU 
ARE APPLYING TOO MUCH CHEMICAL. THE GOAL 
IS TO ACHIEVE EVEN COVERAGE OVER THE TARGET 
SURFACE AREA. 

The system is designed for single or multiple application 

environments. Please use the multiple tank applications 
carefully by marking tanks with your chemical identifiers 

when necessary.  

Application Tips:

 

While depressing the trigger button, move the  
applicator in an “S” pattern from bottom to the top  
of the surface target area in a continuous motion. 

Stay in motion, electrostatically charged droplets will 
accumulate in higher levels at the tip of the applicator 
if you move too slowly while the device is in use.
 

Do not over apply. 

In between chemical changes, press the trigger while 

pointing to the floor or other safe target area for four 
to five seconds to clear the remaining chemical in the 

system. 

1.

 

2.

3.

4.

The system’s battery use is controlled to draw down the  

battery to 20% of available cell power and to then shut off. 

This will eliminate the possibility of unwanted battery  
damage and extend the life of the battery. 

Tips:

Fully charge each battery before use.
Keep connectors clean and dry at all times. 
Insert with battery tab to the left and the battery meter 
facing outwards. 

Do not expose batteries to standing liquid. 

1.

2.

3.

4.

Begin at the farthest point from the doorway, work 
back toward the doorway so you can step out when 
application is complete. 

Aim applicator 3 feet (optimal distance) from the 

surface target area, begin with a smooth figure “S” 

movement aiming below, at, and above the surface 
target area while walking at an average pace  
(continuously moving). 

Make sure you are working in a methodical “S” pattern 
and let your passes overlap when moving to the next 
surface target area. 

Allow treated area to set for contact time as  
recommended by the chemical manufacturer’s  
label before re-entry into the area. 

1.

 

2.

3.

4.

B. Spray Application Process:

C. Fluid Management:

Make sure food and drinks are removed or covered 
before application. 

Spotless, clean interiors require no prep work prior to 
application. 

Loose debris must be swept from floors and other 

surfaces prior to application. 

Inspect the area for mechanical barriers such as: 
magazines on table tops, chairs touching each other, 
a table or a wall. The intended target surface area for 
application will need to be accessible. 

Please cover and remove valuables. Electronics, 

 

furniture, paper or other common necessities do not 
need to be removed from the area.

Once the area has been cleaned, application can 
begin. 

This system in NOT a mechanical cleaner. 

1.

2.

3.

4.

5.

6.

7.

A. Preparing the Spray Area:

D. Battery Management:

Содержание EM36-BPBT-1809

Страница 1: ...EM360 Electrostatic Sprayer User Manual Ver 072220...

Страница 2: ...s well as a convenient convertible design for users We recommend you read through this entire instruction manual before beginning Included are assembly operating and safety instructions Following thes...

Страница 3: ...or damage 2 Depreciation or damage caused by normal wear lack of reasonable and proper maintenance failure to follow operating instructions misuse lack of proper protection during storage or accident...

Страница 4: ...static Sprayer Components 3 Inspection 3 Initial Set Up 4 3 Assembly Operating Instructions Assembly Instructions and Tips 5 4 Spray Application Preparing the Spray Area 8 Spray Application Process 8...

Страница 5: ...es liquid adhesion to targeted surface s The hazards associated with the liquids you choose to apply represent their own unique and important safety requirements Refer to each chemical manufacturer s...

Страница 6: ...ver operate the sprayer if it has been damaged or if it is not working properly Always wear the grounding strap to prevent electrostatic shock Chemical Safety Precautions Read and follow all instructi...

Страница 7: ...g strap snaps to the bottom of the application power pack and is an extra layer of safety in the event static charge accumulates with extended use of the system A simple loop slips over the toe of the...

Страница 8: ...off the system a b c d e f Identify the white or brown portion of the grounding strap ring and install placing the white or brown portion to the bottom of the ball of your shoe Place the elastic stra...

Страница 9: ...r until refill is required You may exchange tanks with different liquids at any time e f Assembly Instructions and Tips IMPORTANT DO NOT DROP TANK INTO THE TANK WELL CAREFULLY APPLY SLIGHT DOWNWARD PR...

Страница 10: ...of power pack housing Black elastic strap stretches around heel of shoe Applicator holder for storage Adjustable clamp to secure power pack in place during use Rubber bumpers 3 Grounding Strap This p...

Страница 11: ...t Handle Rails Handle assembly positions can be adjusted by loosening the two knobs and positioning as desired and then re tightening the knobs Slide holster onto flat clamp before assembling C clamp...

Страница 12: ...battery Tips Fully charge each battery before use Keep connectors clean and dry at all times Insert with battery tab to the left and the battery meter facing outwards Do not expose batteries to stand...

Страница 13: ...exterior with water or alcohol to remove dirt and soil Use the power indicator on the end of the battery to determine the battery state of charge 5 bars full charge Insert battery covers back into ba...

Страница 14: ...OSING BATTERY SLOT WITH A CHARGED BATTERY BATTERY IS MECHANICALLY OBSTRUCTED BATTERY DOES NOT SLIDE EASILY INTO THE SLOT DO NOT TRY AND SLAM THE BATTERY TO SEAT TANK EMPTY VERIFY BATTERY CONNECTOR ISS...

Страница 15: ......

Страница 16: ...1000 Forest Park Blvd Ste 402 Fort Worth TX 76110 Emist com 888 534 7001...

Отзывы: