8

 

|

 ENGLISH

 

SUGGESTION: This UPS is the power supply for the computer, monitor and hard 
disk(CD) etc. It has a limited backup time for the load, so you'd better not connect a 
printer or other equipment to it. 

 
6. 

Press the ON/OFF button on the front of the UPS to turn it on. You will hear a 
short beep. 

 

Remark

 

1.  Generally speaking, don't turn off the UPS so the battery keeps charging. 
2.  When AC fails the UPS will turn to battery mode. Please save important                  

documents in time. 

7.0 UPSilon 2000 software 

The EM3940/41/42 is supplied with UPSilon 2000 software. This software package 
enables you to view the status of the UPS and change multiple settings. During a long 
lasting power failure the software will correctly shut down your computer before the 
battery of the UPS is drained. 

7.1 Installing the software  

1. 

Download the software to your computer . 

2. 

The Setup menu of the software will automatically appear. 

3. 

Click ‘

Install Program

’. 

4. 

Choose your operating system. 

5. 

Click ‘

Next

’. 

6. 

Click ‘

Yes

’. 

7. 

You will now be asked to enter a username, company name and serial number. 
Enter this information. The serial number can be found on the card supplied with 
the UPS. 

8. 

Click ‘

Next

’. 

9. 

C

lick ‘

Yes

’. 

10. 

Click ‘

Next

’. 

11. 

Click ‘

Next

’. 

12. 

Click ‘

Finish

’ to finish the installation of the software. 

13.  Start the UPSilon 2000 software.  
14.  A new screen with four options and a log field will appear. 
15.  Click the opt

ion ‘

Settings

’. 

16.  Select the correct communication for serial communication select 

MegaTec

” and 

COM port number 

near ‘

Select Comm Port

’. Usually this is ‘

COM1

’  for USB 

communication select 

Mega(USB)

”. 

17. 

Click ‘

OK

’. The message ‘UPS connected’ will appear in the log field. If this 

message does not appear, it is possible you selected an incorrect COM port or 
the cable is incorrectly connected. If the serial cable is correctly connected, you 
will need to choose another COM port, as explained in steps 15 and 16. 

Содержание EM394 Series

Страница 1: ...EM394X UPS 600 1000 1500VA...

Страница 2: ...0 UPSilon 2000 software 8 7 1 Installing the software 8 7 2 UPSilon 2000 options and settings 9 7 2 1 Settings 9 7 2 2 Tasks 10 7 2 3 Control 10 7 2 4 Close File 10 7 2 5 Log File 10 7 2 6 About 10 8...

Страница 3: ...equipped with a sound alarm which is activated as soon a power failure occurs warning you to shut down your computer or to make a backup The capacity of the available models is explained below Model...

Страница 4: ...front panel is pressed the UPS will not output voltage It is forbidden to open the case because there is danger with electricity If there is problem please handle with the instruction of experts It is...

Страница 5: ...and provide power for the equipment 3 2 AC Failure When AC fails the battery will supply power to the inverter and then passes filter and provide power for the equipment ensuring the continuous power...

Страница 6: ...off automatically and protect the battery When AC comes back the UPS will turn on automatically Short circuit Protection when the UPS is in inverter mode and there is shock or short circuit UPS will...

Страница 7: ...splay The display shows the following information Input voltage Output voltage The battery status level Power usage in percent UPS status indication Low Battery indication Over load indication 6 0 Ins...

Страница 8: ...omputer 2 The Setup menu of the software will automatically appear 3 Click Install Program 4 Choose your operating system 5 Click Next 6 Click Yes 7 You will now be asked to enter a username company n...

Страница 9: ...has to be saved and how often this needs to be done Shutdown The option Shutdown enables you to establish the steps UPSilon 2000 needs to take as soon a problem with the power supply occurs Enable Tu...

Страница 10: ...to be saved and how often this needs to be done The result can be viewed by clicking the option Log File A maximum of 2000 rows can be recorded You can also print the information or save it to a file...

Страница 11: ...nce of the battery will be weakened faster and accordingly the checking frequency of the battery should be changed to every month 8 3 Handling of abnormity The UPS can serve and provide protection to...

Страница 12: ...ws directives and regulations set out by the European parliament some wireless devices could be subject to limitations concerning its use in certain European member states In certain European member s...

Страница 13: ...of children Wipe off the product with soft fabric not water mop Keep the power plug and outlet clean Do not unplug the device form the power outlet with wet hands Unplug the device when you don t use...

Страница 14: ...t warranty Products are not covered by the Eminent warranty when exposed to incorrect improper use external influences or when opening the service parts of the product by parties other than Eminent Em...

Отзывы: