background image

http://www.enviromaster.com

[email protected]

2

EmI ENGINEERING SUbmIttAL UNH-t2H-t3H-t4H

Model

Circuit

Cooling

Btuh (kW)

Heating

Btuh (kW)

Outdoor 

Indoor Air Handler

T2H8800

(2) UNH24

1

18,000 (5.3)

13,400 (3.9)

2

18,000 (5.3)

13,400 (3.9)

T2H8400

(2) UNH24

1

18,000 (5.3)

13,400 (3.9)

2

24,000 (7.0)

18,700 (5.5)

T2H4400

(2) UNH24

1

24,000 (7.0)

18,700 (5.5)

2

24,000 (7.0)

18,700 (5.5)

T2H2400

(1) UNH12

(1) UNH24

1

11,000 (3.2)

9,200

 (2.7)

2

24,000 (7.0)

18,700 (5.5)

T2H9800

(1) UNH09

(1) UNH24

1

9,200 (2.7)

7,400 (2.2)

2

18,000 (5.3)

13,400 (3.9)

T3H9990

(3) UNH09

1

9,200 (2.7)

7,400 (2.2)

2

9,200 (2.7)

7,400 (2.2)

3

9,200 (2.7)

7,400 (2.2)

T3H9920

(2) UNH09

(1) UNH12

1

9,200 (2.7)

7,400 (2.2)

2

9,200 (2.7)

7,400 (2.2)

3

11,300 (3.3)

9,200

 (2.7)

T3H9980

(2) UNH09

(1) UNH24

1

9,200 (2.7)

7,400 (2.2)

2

9,200 (2.7)

7,400 (2.2)

3

17,900 (5.2)

13,400 (3.9)

T3H9940

(2) UNH09

(1) UNH24

1

9,200 (2.7)

7,400 (2.2)

2

9,200 (2.7)

7,400 (2.2)

3

23,900 (7.0)

18,700 (5.5)

T3H9220

(1) UNH09

(2) UNH12

1

9,200 (2.7)

7,400 (2.2)

2

11,300 (3.3)

9,200

 (2.7)

3

11,300 (3.3)

9,200

 (2.7)

T3H9280

(1) UNH09

(1) UNH12

(1) UNH24

1

9,200 (2.7)

7,400 (2.2)

2

11,300 (3.3)

9,200

 (2.7)

3

17,900 (5.2)

13,400 (3.9)

T3H9240

(1) UNH09

(1) UNH12

(1) UNH24

1

9,200 (2.7)

7,400 (2.2)

2

11,300 (3.3)

9,200

 (2.7)

3

23,900 (7.0)

18,700 (5.5)

(Continued)  

UNH / T2H, T3H, or T4H SySTem 

CapaCiTieS

Model

Cooling

Heating

Outdoor 

Indoor Air Handler

Btuh 

(kW)

SEER

SHR

EER

Btuh 

(kW)

HSPF

COP

T3H9240

(1) UNH09, (1) UNH12, (1) UNH24

44500 (13.0)

13

0.69

11.7

35200 (10.3)

7.7

3.2

T3H2280

(2) UNH12, (1) UNH24

40500 (11.9)

13

0.76

11.8

31800 (9.3)

7.7

3.3

T3H2240

(2) UNH12, (1) UNH24

46500 (13.6)

13

0.68

11.7

37000 (10.8)

7.7

3.2

T3H2220

(3) UNH12

34000 (10.0)

13

0.72

11.7

27600 (8.1)

7.7

3.3

T4H9999

(4) UNH09

37200 (11.0)

13

0.8

11.9

29600 (8.7)

7.7

3.3

T4H9992

(3) UNH09, (1) UNH12

39000 (11.4)

13

0.77

11.8

31400 (9.2)

7.7

3.3

T4H9922

(2) UNH09, (2) UNH12

41000 (12.0)

13

0.76

11.8

33200 (9.7)

7.7

3.3

T4H9222

(1) UNH09, (3) UNH12

43000 (12.6)

13

0.72

11.6

35000 (10.3)

7.7

3.3

T4H2222

(4) UNH12

45000 (13.2)

13

0.72

11.7

36800 (10.8)

7.7

3.3

Circuit Designators: 9 = 9000 Btuh  2 = 12000 Btuh  8 = 18000 Btuh  4 = 24000 Btuh (ex. - 8400 consists of one 18000 Btuh compressor and one 24000 Btuh compressor)

UNH / T2H, T3H, or T4H CirCUiT performaNCe DaTa

Model

Circuit

Cooling

Btuh (kW)

Heating

Btuh (kW)

Outdoor 

Indoor Air Handler

T3H2280

(2) UNH12

(1) UNH24

1

11,300 (3.3)

9,200 (2.7)

2

11,300 (3.3)

9,200 (2.7)

3

17,900 (5.2)

13,400 (3.9)

T3H2240

(2) UNH12

(1) UNH24

1

11,300 (3.3)

9,200 (2.7)

2

11,300 (3.3)

9,200 (2.7)

3

23,900 (7.0)

18,700 (5.5)

T3H2220

(3) UNH12

1

11,300 (3.3)

9,200 (2.7)

2

11,300 (3.3)

9,200 (2.7)

3

11,300 (3.3)

9,200 (2.7)

T4H9999

(4) UNH09

1

9,300 (2.7)

7,400 (2.2)

2

9,300 (2.7)

7,400 (2.2)

3

9,300 (2.7)

7,400 (2.2)

4

9,300 (2.7)

7,400 (2.2)

T4H9992

(3) UNH09

(1) UNH12

1

9,300 (2.7)

7,400 (2.2)

2

9,300 (2.7)

7,400 (2.2)

3

9,300 (2.7)

7,400 (2.2)

4

11,200 (3.3)

9,200 (2.2)

T4H9922

(2) UNH09

(2) UNH12

1

9,300 (2.7)

7,400 (2.2)

2

9,300 (2.7)

7,400 (2.2)

3

11,200 (3.3)

9,200 (2.7)

4

11,200 (3.3)

9,200 (2.7)

T4H9222

(1) UNH09

(3) UNH12

1

9,300 (2.7)

7,400 (2.2)

2

11,200 (3.3)

9,200 (2.7)

3

11,200 (3.3)

9,200 (2.7)

4

11,200 (3.3)

9,200 (2.7)

T4H2222

(4) UNH12

1

11,200 (3.3)

9,200 (2.7)

2

11,200 (3.3)

9,200 (2.7)

3

11,200 (3.3)

9,200 (2.7)

4

11,200 (3.3)

9,200 (2.7)

Отзывы: