background image

3

Except the above parts provided,the other parts needed during installation you must 
purchase.

ACCESSORIES

NOTE

:

SELECT THE BEST LOCATION

There should not be any heat source or stream 
near the unit.
There should not be any obstacles blocking the 
air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into 
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the 
wall,ceiling,fence or other obstacles.
There should not be any direct sunlight. If unavoidable, 
sunlight prevention should be taken into consideration.

Outdoor unit dimension
          mm(WxHxD)

A(mm)

458

460

B(mm)

250

276

530

600

290

320

560

481

335

276

549

276

Mounting dimensions

700x540x240

685x430x260

780x540x250

760x590x285

775x545x310

845x700x320

660x540x265

Indoor  unit

Outdoor  unit

If an awning is built over the unit to prevent 
direct sunsight or rain,be careful that heat 
radiation from the condenser is not obstructed.
There should not be any animal or plant which 
could be affected by hot air discharged.
Keep the spaces indicated by arrow from wall 
ceiling, fence or other obstacles.
Do not place any obstacles which may cause 
a short circuit of the discharged air.

Anchor the outdoor unit with a bolt and nut  

10 or 

8 tightly and horizontally on a concrete or rigid mount.

Settlement of  outdoor unit

NOTE:

 The outdoor unit you purchase may be like one

of the following. Install the outdoor unit according to the
dimension as indicated in the table below:

A

W

B

D

Air inlet 

Air outlet

Air inlet 

1

2

3
4

5

7
8
9
10

6

Installation Plate

Clip Anchor

Self-tapping Screw A ST3.9x25 

Seal(For cooling & heating models only)
Drain Joint(For cooling & heating models only

      

Connecting 
pipe 
Assembly

Liquid side 

Gas side

Remote controller 

Air freshening filter(installed on Air filter)

Self-tapping Screw B ST2.9x10 

6.35
9.52

9.52

12.7

 16 

Parts you must purchase. The pipe 
size differ from appliance to appliance. 
Consult the technician for the proper 
size.

1
5-8(depending on models)

5-8(depending on models)

1

1

1

2

1

1

Remote controller holder

Number Name of  Accessories

Qty 

optional 
parts

Содержание enviroair 12000 Btu

Страница 1: ...ess Inverter Split Systems Installation Operation Manintenance Manual Air Handler Indoor Models FWCA Condenser Outdoor Models FCA An ISO 9001 2008 Certified Company ECR International Inc 2201 Dwyer Av...

Страница 2: ...nd maintenance Operation tips Troubleshooting tips INSTALLATION PRECAUTIONS SAFETY PRECAUTIONS SELECT THE BEST LOCATION INDOOR UNIT INSTALLATION PLATE MOUNTING DRILL A HOLE IN THE WALL CONNECT THE CAB...

Страница 3: ...cted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 6 Wiring routing must be properly arranged so that control board cover is fixed properly If...

Страница 4: ...om the condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrow from wall ceiling fence or other obstacles D...

Страница 5: ...right or the left and the hole should be slightly slanted to the outdoor side 4 Always take steps to protect the pipe when drilling metal grid metal plate or the like DRILL A HOLE IN THE WALL INSTALLA...

Страница 6: ...which located on the side panel of the unit Please refer to the nameplate before selecting the cable fuse and switch NOTE Suggest Minimum Wire Size AWG American Wire Gage Appliance Amps AWG Wire Size...

Страница 7: ...unit Do not allow the piping to let out from the back of the indoor unit Be careful not to let the drain hose slack Heat insulation should be done to the extension drain hose of indoor unit Be sure t...

Страница 8: ...then insert the drain joint into the base pan hole of outdoor unit rotate 90 to securely assemble them To install drain joint as shown in Fig B insert the drain joint into the base pan hole of outdoor...

Страница 9: ...p Additional amount of refrigerant to be charged Open the valve stem until it hits against the stopper Do not try to open it further Securely tighten the valve stem cap with a spanner or the like Valv...

Страница 10: ...ak check at the flare nut connections and electrical safety check Check that all tubing and wiring have been properly connected Check that the gas and liquid side service valves are fully open 1 Conne...

Страница 11: ...10 Before using your air conditioner please read this manual carefully and keep it for future reference 10 Before using your air conditioner please read this manual carefully and keep it for future r...

Страница 12: ...SOCIABLE REMARK DISPOSAL Do not dispose of this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance...

Страница 13: ...may cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or elect...

Страница 14: ...ty etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off and dis...

Страница 15: ...y panel Indoor unit VLED Display Window OPERATION indication lamp This lamp illuminates when the air conditioner is in operation TIMER indication lamp Lights up during Timer operation DEFROST indicati...

Страница 16: ...h for the next operation The unit will operate as following sequence FAN ONLY mode at Low fan speed Heating operation with LOW fan speed applicable to cooling heating modles only FAN ONLY operation St...

Страница 17: ...e floor and set HIGH fan mode Suggestion For the unit adopts an Electric Heater when the outside ambient temperature O O is below 0 C 32 F we strongly recommend you to keep the machine plugged in orde...

Страница 18: ...o not put your fingers into the panel of blower and suction side The high speed fan inside may cause danger Do not operate the air conditioner for long periods with the air flow direction set downward...

Страница 19: ...t it will switch off This mode saves you energy and brings you comfort at night DRYING operation Optimal operation To achieve optimal performance please note the following Adjust the air flow directio...

Страница 20: ...h a soft dry cloth Do not use bleach or abrasives NOTE Power supply must be disconnectd before cleaning the indoor unit Filter Handle Cleaning the air filter A clogged air filter reduces the cooling e...

Страница 21: ...rts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to...

Страница 22: ...in HEAT mode operation after defrosting 3 Low noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running It is the sound of the refrigera...

Страница 23: ...re If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 10 Auto restart function Power failure during operation will stop the unit co...

Страница 24: ...indows are open Air inlet or outlet of indoor or outdoor unit has been blocked Compressor 3 or 4 minutes protection has been activated If the trouble has not been corrected please contact a local deal...