background image

The Ductless Split System of Choice

Made in Rome, New York, USA

15

R

EFRIGERANT

 C

HARGE

 T

ABLES

 - S

INGLE

 Z

ONE

 (S

TRAIGHT

 C

OOL

)

p

a

v

E

le

d

o

M

e

n

iL

T

F

/

G

H

C

e

n

iL

h

t

g

n

e

L

)t

f(

la

t

o

T

ts

u

jd

A

y

r

o

tc

a

F

e

g

r

a

h

C

-

e

ts

y

S

m

la

t

o

T

4

2

-

P

H

C

/

P

S

C

4

2

-

P

H

W

/

P

S

W

4

2

-

P

H

F

/

P

S

F

4

2

H

A

C

.

z

o

6

5

.

0

1

5

2

0

5

.

z

o

6

.

z

o

4

1

.

z

o

8

2

z

o

0

5

.

z

o

6

5

.

z

o

4

6

.

z

o

8

7

SCC-24

p

a

v

E

le

d

o

M

e

n

i

L

T

F

/

G

H

C

e

n

i

L

h

t

g

n

e

L

)t

f(

la

t

o

T

t

s

u

j

d

A

y

r

o

t

c

a

F

e

g

r

a

h

C

m

e

t

s

y

S

la

t

o

T

2

1

-

P

H

C

/

P

S

C

2

1

-

P

H

W

/

P

S

W

2

1

-

P

H

F

/

P

S

F

2

1

-

H

/

C

B

T

2

1

H

A

C

.

z

o

5

2

.

0

1

5

2

0

5

.

z

o

3

.

z

o

6

.

z

o

3

1

z

o

5

.

9

2

.

z

o

2

3

.

z

o

5

3

.

z

o

2

4

SCC-12

p

a

v

E

le

d

o

M

e

n

i

L

T

F

/

G

H

C

e

n

i

L

h

t

g

n

e

L

)t

f(

la

t

o

T

t

s

u

j

d

A

y

r

o

t

c

a

F

e

g

r

a

h

C

m

e

t

s

y

S

la

t

o

T

5

1

-

P

H

C

/

P

S

C

5

1

-

P

H

W

/

P

S

W

5

1

-

P

H

F

/

P

S

F

5

1

-

H

/

C

B

T

5

1

H

A

C

.

z

o

5

2

.

0

1

5

2

0

5

.

z

o

3

.

z

o

6

.

z

o

3

1

z

o

5

.

3

4

.

z

o

5

.

6

4

.

z

o

5

.

9

4

.

z

o

5

.

6

5

SCC-15

p

a

v

E

le

d

o

M

e

n

i

L

T

F

/

G

H

C

e

n

i

L

h

t

g

n

e

L

)t

f(

la

t

o

T

t

s

u

j

d

A

y

r

o

t

c

a

F

e

g

r

a

h

C

m

e

t

s

y

S

la

t

o

T

4

2

-

P

H

C

/

P

S

C

4

2

-

P

H

W

/

P

S

W

4

2

-

P

H

F

/

P

S

F

4

2

-

H

/

C

B

T

4

2

H

A

C

.

z

o

6

5

.

0

1

5

2

0

5

.

z

o

6

.

z

o

4

1

.

z

o

8

2

z

o

5

3

.

z

o

1

4

.

z

o

9

4

.

z

o

3

6

SCC-18

SCC-09

p

a

v

E

le

d

o

M

e

n

i

L

T

F

/

G

H

C

e

n

i

L

h

t

g

n

e

L

)t

f(

la

t

o

T

t

s

u

j

d

A

y

r

o

t

c

a

F

e

g

r

a

h

C

m

e

t

s

y

S

la

t

o

T

2

1

-

P

H

C

/

P

S

C

2

1

-

P

H

W

/

P

S

W

2

1

-

P

H

F

/

P

S

F

2

1

-

H

/

C

B

T

2

1

H

A

C

.

z

o

5

2

.

0

1

5

2

0

5

.

z

o

3

.

z

o

6

.

z

o

3

1

z

o

5

.

6

2

.

z

o

9

2

.

z

o

2

3

.

z

o

9

3

p

a

v

E

le

d

o

M

e

ni

L

T

F

/

G

H

C

e

ni

L

ht

g

n

e

L

)t

f(

la

t

o

T

ts

uj

d

A

y

r

ot

c

a

F

e

g

ra

h

C

m

et

s

y

S

la

t

o

T

0

3

-

P

H

C

/

P

S

C

0

3

-

P

H

W

/

P

S

W

0

3

-

P

H

F

/

P

S

F

0

3

H

A

C

.

z

o

6

5

.

0

1

5

2

0

5

.

z

o

6

.

z

o

4

1

.

z

o

8

2

z

o

4

6

.

z

o

0

7

.

z

o

8

7

.

z

o

2

9

SCC-30

p

a

v

E

le

d

o

M

e

ni

L

T

F

/

G

H

C

e

ni

L

ht

g

n

e

L

)t

f(

la

t

o

T

ts

uj

d

A

y

r

ot

c

a

F

e

g

ra

h

C

m

et

s

y

S

la

t

o

T

6

3

-

P

H

C

/

P

S

C

6

3

-

P

H

W

/

P

S

W

6

3

-

P

H

F

/

P

S

F

6

3

H

A

C

.

z

o

6

5

.

0

1

5

2

0

5

.

z

o

6

.

z

o

4

1

.

z

o

8

2

z

o

5

6

.

z

o

1

7

.

z

o

1

7

.

z

o

3

9

SCC-36

p

a

v

E

le

d

o

M

e

ni

L

T

F

/

G

H

C

e

ni

L

ht

g

n

e

L

)t

f(

la

t

o

T

ts

uj

d

A

yr

ot

c

a

F

e

g

ra

h

C

m

et

s

y

S

la

t

o

T

2

4

-

P

H

C

/

P

S

C

2

4

-

P

H

W

/

P

S

W

2

4

-

P

H

F

/

P

S

F

2

4

H

A

C

.

z

o

5

6

.

0

1

5

2

0

5

.

z

o

7

.

z

o

6

1

.

z

o

3

3

z

o

1

0

1

.

z

o

8

0

1

.

z

o

7

1

1

.

z

o

4

3

1

CCB-42

To determine charge adjustment and system charge

for any evaporator and tubing length:

Total Adjustment= (Line Charge/FT) x Line Length

System Total= Factory Total Adjustment

NOTE: Round down to nearest ounce and allow
for gauges and hoses.

p

a

v

E

le

d

o

M

e

ni

L

T

F/

G

H

C

e

ni

L

ht

g

n

e

L

)t

f(

la

to

T

ts

uj

d

A

yr

ot

c

a

F

e

gr

a

h

C

m

et

s

y

S

la

to

T

8

4

-

P

H

C

/

P

S

C

8

4

-

P

H

W

/

P

S

W

8

4

-

P

H

F

/

P

S

F

8

4

H

A

C

.

z

o

4

7

6

.

0

1

5

2

0

5

.

z

o

7

.

z

o

7

1

.

z

o

4

3

z

o

2

0

1

.

z

o

9

0

1

.

z

o

9

1

1

.

z

o

6

3

1

CCB-48

Содержание AmericaSeries LLC-09

Страница 1: ...the side and 48 to the front and rear be GENERAL INFORMATION This guide is intended for use by EMI contractors distributors installers representatives and service technicians to gain a better underst...

Страница 2: ...ndenser is equipped with low ambient fan control for cooling The fan will remain off while in cooling mode until the condenser pressure reaches 275psi The fan will then energize and run until the cond...

Страница 3: ...ng conditions are met properly see EMI Policy Bulletin 910503 All equipment capacities must have the same BTU h rating and efficiency rating SEER A transformer must be added to the outdoor unit if not...

Страница 4: ...ave a P trap installed at the base to facilitate oil return when the condenser is above the evaporator Fig 1 When the evaporator is installed above the compres sor the trap will prevent the flow of li...

Страница 5: ...ft of 4 feet from the bottom of the unit NOTE Before completing installation test pump action EMI offers external pumps for installations that re quire more than 4 feet of lift SYSTEM TROUBLESHOOTING...

Страница 6: ...ct inside the fittings for any for eign particles that may have collected there The for eign particles can consist of pieces of valves wind ings or thermal overload particles and other related items n...

Страница 7: ...ession fittings Ethylene or propylene is recommended Bleed air from system prior to start up Units are equipped with a standard air bleeder on the highest point of the unit piping CAUTION Disconnect p...

Страница 8: ...NTRO L B AT T E R IE S INCL UDE D POWER ON OFF Button INFRA RED SENSOR T EMP SET POINT DOWN Button T EMP SET POINT UP Button LCD Display HEAT OPERAT ION Indicator FAN LOW Indicator FAN HIGH Indicator...

Страница 9: ...Y wire When the air handler is calling for cooling 24v can be measured between terminals wires Y and C NOTE Most condenser manufacturers do not supply low volt transformers with their condensers When...

Страница 10: ...ereby cutting the Y signal to the condenser This will prevent the evaporator from generating more condensation and spilling out of the unit FREEZE PROTECTION The indoor fan coil unit is protected in t...

Страница 11: ...ton in Place the setpoint tem perature above the room temperature The compressor will start heating and run as long as the setpoint is above the room temperature Some EMI heat pump condensers are equi...

Страница 12: ...ar may not work for a unit manufactured in a dif ferent model year NOTE EMI does not stock or recommend electric heat add on kits for field installation It is critical that if you can foresee the need...

Страница 13: ...______________________________________ Subcooling ___________________________________________________________ Suction Temperature at Compressor _____________________________________ Voltage Running __...

Страница 14: ...a F e g r a h C m e t s y S l a t o T 2 1 W C L z o 5 2 0 1 5 2 0 5 z o 3 z o 6 z o 3 1 z o 0 3 z o 3 3 z o 6 3 z o 3 4 LCC 12 p a v E l e d o M e n i L T F G H C e n i L h t g n e L t f l a t o T t...

Страница 15: ...r o t c a F e g r a h C m e t s y S l a t o T 2 1 P H C P S C 2 1 P H W P S W 2 1 P H F P S F 2 1 H C B T 2 1 H A C z o 5 2 0 1 5 2 0 5 z o 3 z o 6 z o 3 1 z o 5 6 2 z o 9 2 z o 2 3 z o 9 3 p a v E l...

Страница 16: ...L t f l a t o T t s u j d A y r o t c a F e g r a h C m e t s y S l a t o T 2 1 P H C 2 1 P H F 2 1 P H W 2 1 H B T 2 1 H A C z o 5 2 0 1 5 2 0 5 z o 3 z o 6 3 1 z o z o 2 4 z o 5 4 z o 8 4 z o 5 5 S...

Страница 17: ...e g r a h C m e t s y S l a t o T 4 2 P H C P S C 4 2 P H F P S F 4 2 P H W P S W 4 2 H C B T 4 2 H A C 6 5 0 1 5 2 0 5 z o 6 z o 4 1 z o 8 2 z o 1 4 z o 7 4 z o 5 5 z o 9 6 MH 18 l e d o M p a v E e...

Страница 18: ...5 1 1 0 8 2 0 2 2 5 7 5 7 1 5 6 2 0 6 2 5 2 1 5 2 2 0 0 2 0 8 0 7 1 0 6 2 0 6 2 5 2 1 5 8 1 0 8 1 5 8 0 6 1 5 5 2 0 4 2 5 2 1 5 8 1 0 6 1 0 9 5 5 1 5 4 2 0 3 2 0 1 1 5 4 1 0 6 1 5 9 0 5 1 5 4 2 0 2 2...

Страница 19: ...in Degrees F p m e T D O F s e e r g e D 9 0 2 1 5 1 8 1 4 2 0 3 6 3 5 6 5 4 3 5 8 2 0 1 2 5 9 1 5 4 2 0 2 2 0 3 2 0 7 0 7 2 0 7 2 0 1 2 0 9 1 0 4 2 5 3 2 0 3 2 5 7 5 1 2 0 6 2 0 1 2 0 9 1 0 4 2 0 4...

Страница 20: ...20 EMI Products are subject to ongoing development Products Specifications may change without notice O L Over Load...

Страница 21: ...ump Pending Slv Brg Whl C 265V 60Hz E X Special 220 240V 50Hz F A Standard 0 Standard B No Expansion KW X Special C Open 208V 230V 265V D Open NONE 0 0 Unit Mount w Trans Mechanical E Aeroquip 2 50 3...

Страница 22: ...C 1 2 D A 0 0 0 0 A A 0 A A SCC C Straight Cool 0 Standard SHC H Heat Pump A Z A Standard 9 000 BTU 09 A Standard 12 000 BTU 12 X Special 15 000 BTU 15 0 Painted Coil No Grille Std 115V 60Hz A A Coat...

Страница 23: ...____________________________________________ __________________________________________________________________________________________ ________________________________________________________________...

Страница 24: ...almaintenance Damage or repairs required as a consequence of faulty installation or application by other Failure to start due to voltage conditions blown fuses open circuit breakers or other damages d...

Отзывы: