Operating fluid
ELHY
®
thrusters are delivered from the factory with operating fluid
that depends on the usage conditions and the required version. The
type of operating fluid that the thruster was filled with is specified on
the type plate.
NOTICE
Observe the safety data sheet issued by the oil manufacturer.
The type of operating fluid already in the thruster must always be
used to top it up.
Mixing different hydraulic media is not permitted!
When changing the operating fluid, the ELHY
®
thruster must be
completely drained beforehand.
Table 22:
Filling quantities for operating fluid- TGL 35868 / DIN 15430 series
TGL 35868 series
DIN 15430 series
Special versions
Fill quantity in
litres, approx.
EB 120-40
1.2
EB 12/50
EB 220-50
2.6
EB 20/50
EB 300-50
1.8
EB 50/50
EB 500-60
EB 320-50, EB 500-50
2.6
EB 50/100
EB 500-120
EB 500-100
3.5
EB 80/60, EB 125/60,
EB 150/60
EB 800-160, EB 1250-60
EB 1500-60
4.3
EB 80/160, EB 125/160,
EB 150/160
EB 800-120, EB 1250-120
EB 800-160, EB 1250-160,
EB 1500-160
6.0
EB 250/60
EB 2000-60
EB 2500-60
9.0
EB 250/160
EB 2000-120
EB 2500-160
9.0
EB 320/100
EB 3000-60, EB 3000-120
EB 3200-100
10.1
EB 630/120
EB 6300-80, EB 6300-120
10.6