Emerson YARWAY 9100 ARC Series Скачать руководство пользователя страница 3

3

 

2

[50]

[40]

10 - 24

[90]

[38]

1

/

16

[27]

7

/

32

[6]

1

/

16

[1.5]

3

[80]

2

[50]

¼ - 20

4

[102]

[38]

1⅜

[35]

9

/

32

[7]

1

/

16

[1.5]

4

[100]

3

[80]

¼ - 20

[140]

[45]

1

/

16

[52]

9

/

32

[7]

[3]

6

[150]

4

[100]

5

/

16

 - 18

7

[178]

[57]

2⅞

[73)

11

/

32

[9]

[3]

8

[200]

6

[150]

⅜ - 16

[222]

3

[76]

[121]

13

/

32

[10]

[3]  

YARWAY 

9100 SERIES ARC

®

 VALVE

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

OPERATIONAL CHECK

When the valve is properly installed the 
combined main and bypass flows should 
equal or exceed that of the specified minimum 
pump flow. If operational checks indicate a 
deviation from the original specifications and 
field adjustments are necessary, contact the 
Emerson for additional information.

VALVE CARE

Except for periodic operational checks the valve 
requires little maintenance. The disc assembly, 
spring and bypass bushing should be inspected 
coincident with the other annual inspections. 
Inspection of the valve’s internal components 
may be necessary more often if the valve is 
cycled often or remains in bypass mode for 
extended periods. The mechanism is easily 
removed whenever the main flow is stopped. 
Make certain that all pressure is relieved and 
the pipeline is secured against pressurization 
before attempting disassembly for inspection 
purposes.

TABLE 1 – INTEGRAL BACK PRESSURE REGULATOR DRAW BOLT AND WASHER

Valve Size 

BPR Size

Bolt Thread

Bolt Length

Minimum Thread Length

Washer OD

Washer ID

Washer Thickness

in.

[mm]

in.

[mm]

in.

in.

[mm]

in.

[mm]

in.

[mm]

in.

[mm]

in.

[mm]

Typical installation

3 diameters recommended and 

minimum straight pipe on outlet

Pump warm-up 

line (optional)

Receiver vessel

Optional location 

of back pressure 

regulator when 

required

Long radius 

pipe bends

Size line for maximum velocity 

of 15 ft/sec [5 m/sec]

Optional check valve

10 diameters recommended 

minimum straight pipe on inlet

From 

pump

Содержание YARWAY 9100 ARC Series

Страница 1: ...lation of bypass flow as required 2 Compact self contained design that eliminates divided installation responsibility occurring with systems involving combinations of pneumatic thermal and mechanical devices 3 Minimum wear on vital parts during pressure reduction of bypass flow 4 Quiet pressure drop provided by a bypass that dissipates the energy effectively For high pressure drop capability and o...

Страница 2: ...specified minimum pump flow and the combined main and bypass flow provide a total greater than the pump minimum flow requirement Bypass flow enters the bypass element at the bottom of the bypass stem The flow is then controlled by the port openings in the side of the bypass stem The flow continues through the annulus in the bypass bushing and is directed to the outlet of the valve For applications...

Страница 3: ...pected coincident with the other annual inspections Inspection of the valve s internal components may be necessary more often if the valve is cycled often or remains in bypass mode for extended periods The mechanism is easily removed whenever the main flow is stopped Make certain that all pressure is relieved and the pipeline is secured against pressurization before attempting disassembly for insp...

Страница 4: ...move A 1 x 2 x 25 x 50 x 3 mm thick steel plate and an adjustable wrench may be used if a suitable spanner wrench is not available 4 Remove the disc bypass bushing assembly Items 33 34 36 37 38 39 40 and 42 by applying force to the bottom of the disc as follows Push on the bottom of the disc with a 1 25 mm diameter bar until the spring is fully compressed Tap on the bar with a mallet if additional...

Страница 5: ... anti seize on threads Bend the lockwasher tab in the slot of the locknut LUBRICANTS Use the following lubricants or their equivalents Anti seize Loctite 116737 food grade anti sieze O ring Silicone lubricant or liquid soap TABLE 3 BYPASS BUSHING NUT Valve Size Nut Size Torque in mm in ft lb N m 6 Lap the disc to the body First use 180 grit medium coarse and repeat with 360 grit fine The finished ...

Страница 6: ...m in mm 11 For valves with an integral back pressure regulator a Install new regulator capsule if defective Lube the O ring with O ring lubricant and install the back pressure regulator capsule into the body b Install the spiral ring into the body groove lubricate bottom side with Anti Seize c Coat exposed threads with a thread locking adhesive appropriate for the valve service temperatures Back t...

Страница 7: ...re the disc bypass bushing assembly for installation in the valve body as described by 5a or 5b below as applicable a For the old restraining method a tool must be fashioned by bending a metal rod as shown Compress and rotate the disc and bypass bushing together to align the assembly holes Insert the spring restrainer tool in the assembly holes and release the spring load b For the new restraining...

Страница 8: ... 1 Body ASTM A351 type CF8M J92900 2 Bonnet ASTM A351 type CF8M J92900 3 2 Disc ASTM A479 type S21800A Nitronic 60 bar 4 1 2 Snubber seal assembly Turcite 51 Glyd ring and TFE Propylene O ring 5 2 Bypass bushing ASME SA564 Grade 630 17 4 PH Bar Condition SA S17400 6 1 2 O ring TFE Propylene 7 1 2 O ring TFE Propylene 8 1 2 Spiral ring Inconel X 750 9 1 2 Bypass tube ASTM A312 type 304 10 Spring re...

Страница 9: ...our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice Emerson com FinalControl PARTS AND MATERIALS Item Part Material 1 Body ASTM A 216 Grade WCB 2 Bonnet ASTM A 216 Grade WCB 3 2 Disc assembly bypass element 2 to 6 ASTM A351 type CF10SMnN Nitronic 60 Cast 8 to 12 ASTM A351 type ...

Отзывы: