INSTALLATION 

 

over the marks. Use the mounting  panel  

 

as a template to drill 3/16" holes through  

 

each of the holes marked "A". Install the   

 

replacement control in the freshly drilled holes  

 

in the blower access panel. Use aluminum tape  

 

to seal the unused holes.

B. 

When replacing original 63K8901 board in 
downflow applications
 – Look at the existing 
control board holes as if the unit were installed 
in the upflow position. Make a mark 5/8" 
ABOVE each of the existing mounting holes. 
Position the provided mounting panel so that 
the holes marked "C" in figure 1, page 3 are 
over the marks. Use the mounting panel as a 
template to drill 3/16" holes through each of 
the holes marked "A". Install the replacement 
control in the freshly drilled holes in the blower 
access panel. Use aluminum tape to seal the 
unused holes.

C.  

All other units – Position the provided 
mounting panel so that the arrow on the 
front of the panel is pointing up. Position the 
replacement 50A66-843 ignition control board 
over the holes marked "A" in figure 1, page 3.

 

Insert the replacement control stand-off 
fasteners into the holes in the mounting panel.

 

80UHG, 90UGF, G23, G26, GHR26, G32, 
GHR32, G40, G41, G50, G51, G60 and G61 
units –
 Insert the four provided stand-off 
fasteners into the back of the mounting panel in 
the holes marked "B" in figure 1. 

80MGF, G24M 

and G27M units –  Insert the four provided 
stand-off fasteners into the back of the mounting 
panel into the holes marked "C" in figure 1. 

 

Insert the replacement control board assembly 
into the existing holes in the control box or 
blower panel.

5.  Insert provided circuit breaker in series between 

the blue wire on Pin 3 of the wiring harness (9-pin 
to 12-pin) and the blue transformer wire. Optional 
4" blue wire provided for transformers that have a 
quick-connect terminal.

6.   Connect the provided 9-pin to 12-pin wiring 

harness to the unit 9-pin connector.

7.  Connect the provided 4-pin to 6-pin wiring harness 

to the unit 6-pin connector.

8.  Connect the yellow wire from position 6 on the 12-

pin connector to the yellow transformer wire. 

9.  Connect GND wire to equipment ground.
10.  Connect the remaining 120 VAC hot and neutral 

wires and the flame sense wire to the replacement 
control per table 2, page 5 .

11.  Affix wiring diagram 5001-6972 adjacent to the 

existing unit wiring diagram

12.  Replace the access panel.
13.  Restore the electrical power and gas supply. Refer 

to the furnace installation instructions for start-up 
and check-out procedures.

1.  Disconnect all electrical power and shut off the gas 

supply to the furnace.

2.  Remove the access panel.
3.  Disconnect wiring and remove existing ignition 

control board from the control box.

4.   A. 

When replacing original 63K8901 board  

 

in upflow or horizontal applications or   

 

downflow applications – Look at the existing  

 

control board holes as if the unit were installed  

 

in the upflow position. Make a mark 1" to the 

 

 

right of each of the existing mounting holes. 

 

 

Position the provided mounting panel so that 

 

 

the holes marked "C" in figure 1, page 3 are  

Optional 4" blue 

wire to connect to 

Transformer (TH)

Circuit breaker
in series between 
Pin 3 and Trans-
former (TH)

Wiring harness
(4-pin to 6-pin)

Mounting panel

Wiring harness
(9-pin to 12-pin)

Transformer

GND

TABLE 1

Type

Existing 

Control Board

Replacement 

Control Board

L1

120 VAC

COOL-H

COOL

HEAT-H

HEAT

PARK (2)

PARK (2)

EAC-H

EAC

LINE-H

LINE

XFMR-H

XFMR

HUM-H

HUM

NONE

FAN

Neutral 

120 VAC

LINE-N

Neutral 

120 VAC

(5)

HUM-N

EAC-N

XFMR-N

CIR-N

Flame Sense

E33

FS

PROCEDURE 2 

REPLACING 24L8501, 50A62-120, 50A62-121, 

50A62-820, 56L8301, 63K8901 or 97L4801

Photo 2

Содержание White-Rodgers 21D83M-843

Страница 1: ...act with water dripping spraying rain etc If the control has been in direct contact with water replace the control Label all wires before disconnection when servicing controls Wiring errors can cause improper and dangerous operation Route and secure wiring away from flame SHOCK HAZARD Disconnect electric power before servicing Ensure proper earth grounding of appliance Ensure proper connection of ...

Страница 2: ...idual products of combustion between the failed trial for ignition and the retry period 15 Post Purge The period of time intended to allow for the dissipation of any unburned gas or residual products of combustion at the end of a furnace burner operating cycle Post purge begins at the loss of flame sense 5 Lockout Time ANSI standard rated module timing 250 Heat Delay To Fan On The period of time b...

Страница 3: ...cement 50A66 843 ignition control board over the holes marked A in figure 1 Insert the replacement control stand off fasteners into the holes in the mounting panel 6 Insert the four provided stand off fasteners into the back of the mounting panel in the holes marked B in figure 1 Insert the replacement control board assembly into the existing holes in the control box or blower panel 7 Insert provi...

Страница 4: ...ue transformer wire Optional 4 blue wire provided for transformers that have a quick connect terminal 6 Connect the provided 9 pin to 12 pin wiring harness to the unit 9 pin connector 7 Connect the provided 4 pin to 6 pin wiring harness to the unit 6 pin connector 8 Connect the yellow wire from position 6 on the 12 pin connector to the yellow transformer wire 9 Connect GND wire to equipment ground...

Страница 5: ...te with the 50A66 843 s adap tive ignition routine to ensure the most efficient ignitor temperature At the end of the ignitor warm up time both valves in the gas valve are opened Flame must be detected within 4 seconds If flame is detected the delay to fan on period begins After the delay to fan on period ends the circulator fan is energized at heat speed If there is an optional electronic air cle...

Страница 6: ...out or a shorted or open condition in the flame probe circuit will be sensed within 2 seconds The gas valve will de energize andthecontrolwillrestarttheignitionsequence Recycles will begin and the burner will operate normally if the gas supply returns or the fault condition is corrected before the last ignition attempt Otherwise the control will go into system lockout If the control has gone into ...

Страница 7: ...ng and verify furnace is grounded properly Slow flash Off Flame sensed with gas valve de energized Verify the gas is operating and shutting down prop erly Flame in burner assembly should extinguish promptly at the end of the cycle Check orifices and gas pressure On Slow flash Open rollout switch Verify continuity through rollout switch circuit On On Module internal fault condition Module contacts ...

Страница 8: ...White Rodgers is a business of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co white rodgers com emersonclimate com ...

Отзывы: