background image

16

U.L. Model No.: CF130

Repair Parts

16

17

10

8

20

13

9

18

7

19

1

21

22

12

4

0

3

2

1

3

2

4

6

11

14

15

5

Содержание TILO CF130BS00

Страница 1: ... Location Mini Ceiling Fan Owner s Manual Model Numbers CF130BS00 Brushed Steel CF130ORB00 Oil Rubbed Bronze CF130WW00 Appliance White Net Weight 10 6 Lbs 1 800 654 3545 www emersonfans com Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday ...

Страница 2: ... fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE Thi...

Страница 3: ... If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A B D F 4 0 3 2 1 I H C G E PACKAGE CONTENTS 4 1 2 3 5 6 7 10 11 9 ...

Страница 4: ...ire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 4 U L Model No CF130 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Accep...

Страница 5: ...ade screws Figure 1 NOTE Take care not to scratch fan housing assembly when installing blades 4 Complete the remaining two blades installation per the above instructions 5 Remove the three M4 x 8mm flat head screws from the switch housing adapter plate Figure 2 Retain the screws for future installation 6 Engage the connector of the switch housing assembly with the motor connector Figure 2 The two ...

Страница 6: ...in holes in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 5 The clevis pin must go through the holes in the motor coupler and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpi...

Страница 7: ...wo holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 8 The fan comes with blue black and white leads that are 42 long Before installing fan measure up approx imately 6 to 9 inches above top of hanger bal...

Страница 8: ...Motor Housing For Close to the Ceiling Mounting CEILING FLOOR AT LEAST 7 Figure 11 How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 11 WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support of 22 7kg 50 lbs or less WARNING To reduce t...

Страница 9: ...ll WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING CEILING COVER HOOK HOOK ON HANGER BRACKET MUST PASS THROUGH SCREW HOLE IN CE...

Страница 10: ...s and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING 1 Carefully lift the fan assembly and seat the hanger ball in the hanger bracket Figure 15 The tab on the hanger bracket must seat in the groove in the hanger ball How to Hang Your Ceiling Fan For Standard Mounting ...

Страница 11: ...CONNECTOR BLUE FAN WIRE Figure 16 Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING 2 Securely connect the fan motor white wire to the su...

Страница 12: ...ompletely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING Installation of Ceiling Cover For Standard Mounting LOOSEN THIS SCREW TIGHTEN SCREW FAN HOUSING CEILING COVER INSTALL SCREW AND LOCKWASHER Figure 17 NOTE When installing the ceiling fan using the close to the ceiling method carefully lift the fan assembly from the hook on the hanger bracket and procee...

Страница 13: ... marked 1 4 0 position is OFF Figure 19 3 All fans are shipped from the factory with the reversing switch positioned to circulate air downward If airflow is desired in opposite direction turn your fan OFF and wait for the blades to stop turning then slide the reversing switch to the opposite position and turn fan on again Figure 20 4 The fan blades will turn in the opposite direction and reverse t...

Страница 14: ...talog 3 Light Kits see store or catalog Accessories The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ...

Страница 15: ... over tight 3 Fan wobbles 1 Setscrews in motor coupling are not 1 Raise coupling cover and tighten setscrews securely excessively tightened securely 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball downrod assembly is loose assembly 3 Screws securing fan blade to motor are 3 Check to be sure screws which attach the fan loose blade to the motor are tight 4 Fan blade are n...

Страница 16: ...16 U L Model No CF130 Repair Parts 16 17 10 8 20 13 9 18 7 19 1 21 22 12 4 0 3 2 1 3 2 4 6 11 14 15 5 ...

Страница 17: ... Downrod 4 5 4 Cover Ceiling 764029 BS 764029 ORB 764029 WW 5 Decorative Upper Cover 2 764030 BS 764030 ORB 764030 WW 6 Decorative Lower Cover 764031 BS 764031 ORB 764031 WW 7 Coupler Cover 764032 BS 764032 ORB 764032 WW 8 Harness Wiring 764041 764041 764041 9 Switch Housing 764040 BS 764040 ORB 764040 WW 10 Blade Assembly 764038 DC 764038 DC 764038 WW 11 SW46 Wall Control 1 761971 761971 761971 P...

Страница 18: ...18 U L Model No CF130 Notes ...

Страница 19: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Страница 20: ...r Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP73780002 Form No BP7404 1 Revision 130607 U L Model No CF130 Printed in China 06 13 ...

Отзывы: