Emerson SR110 Скачать руководство пользователя страница 6

6

13. For Ceiling Fan Models F2100,

F2200, CF2300, CF2500 and
CF3900 Only. 
Locate and remove the
connector from the yellow wire from
the uplight (Figure 7). Separate,
untwist and unkink the 80” yellow wire
lead (supplied with the fan) and cut off
the connector from the end of the
wire. Strip 1/2-inch of insulation from
the end of this wire. Then join the 80”
yellow wire to the yellow wire from the
uplight using a wire connector
(supplied).

NOTE: The red and brown wires
coming from the top of the motor are
capped with wire connectors. DO NOT
remove these connectors.

2

1

80" YELLOW WIRE

BROWN
WIRE

DO NOT REMOVE THESE
WIRE CONNECTORS

RED WIRE

YELLOW WIRE
FROM UPLIGHT

REMOVE WIRE CONNECTOR 
FROM YELLOW WIRE FROM 
UPLIGHT
JOIN 80" YELLOW WIRE 
USING WIRE CONNECTOR

Figure 7

14. For Ceiling Fan Models CF4500

and CF4800 Only. Locate the two
yellow wires terminated by a wire
connector. Remove the wire
connector and separate the wires
(Figure 8). One yellow wire comes
from the motor coupling; cap the end
of this wire using a wire connector
(supplied) (Figure 9). Separate,
untwist and unkink the 80” yellow wire
lead (supplied with the fan) and cut off
the connector from the end of the
wire. Strip 1/2-inch of insulation from
the end of this wire. Then join the 80”
yellow wire to the yellow wire from the
uplight using a wire connector
(supplied). (Figure 9).

NOTE: The red and brown wires
coming from the top of the motor are
capped with wire connectors. DO NOT
remove these connectors.

14A. For Ceiling Fan Models CF2400

Only. Cut the yellow wire midway
between the motor coupling and the
grommet in the inside of the housing
(orange wire on older CF2400
models). Cap the yellow wire coming
from the motor coupling using a wire
connector (supplied). Separate,
untwist and unkink the 80” yellow
wire lead (supplied with the fan) and
cut off the connector from the wire.
Strip 1/2-inch of insulation from the
end of this wire. Then join the 60”
yellow wire to the yellow wire coming
from the inside of the housing using
a wire connector.

YELLOW WIRE FROM
MOTOR COUPLING

BROWN
WIRE

DO NOT REMOVE THESE
WIRE CONNECTORS

RED WIRE

YELLOW WIRE
FROM UPLIGHT

REMOVE WIRE
CONNECTOR

MOTOR COUPLING

2

1

Figure 8

INSTALL WIRE 
CONNECTOR

INSTALL 80" YELLOW WIRE

BROWN
WIRE

DO NOT REMOVE THESE
WIRE CONNECTORS

YELLOW WIRE
FROM UPLIGHT

RED WIRE

MOTOR 
COUPLING

YELLOW WIRE
FROM MOTOR COUPLING

INSTALL 
WIRE 
CONNECTOR

3

2

4

Figure 9

15. For Ceiling Fan Models CF1 and

CF2800 Only. No wiring changes are
required on top of the motor; proceed
to Step 16.

BP7270-1  5/6/05  1:29 PM  Page 6

Содержание SR110

Страница 1: ...wner s Manual For use only with Emerson Ceiling Fan Models F2100 1 F2200 1 F2300 1 CF1 0 CF2300 0 CF2400 1 CF2500 0 CF2800 0 CF3900 0 CF4500 1 and CF4800 1 OFF REV LOW MED HIGH UP DN Model SR110 Remote Control Model SW105 Receiver NOTE The SR110 Remote Control must be used with a SW105 Receiver BP7270 1 5 6 05 1 29 PM Page 1 ...

Страница 2: ... to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications...

Страница 3: ...rol transmitter and how to set the operating frequency of the transmitter and receiver These instructions must be performed prior to installation of the ceiling fan as described in the second section CEILING FAN PROCEDURES REMOTE CONTROL PROCEDURES General Your Emerson Ceiling Fan Light Remote Control consists of a hand held transmitter and a receiver which is mounted under the fan ceiling cover T...

Страница 4: ...ing Figure 2 2 All Ceiling Fan Models Disconnect the motor connector from the wiring harness connector Figure 2 Remove the knurled nut securing the speed control switch to the switch housing HOUSING COVER TYPICAL SCREW TYPICAL SCREW 2 KNURLED NUT SPEED CONTROL SWITCH PULL CHAIN PLUG REVERSING SWITCH SWITCH HOUSING CAPACITOR MOTOR CONNECTOR WIRING HARNESS CONNECTOR Figure 2 3 For Ceiling Fan Models...

Страница 5: ...he uplight switch or reversing switch by installing pull chain plug s supplied in the hole s See Figures 2 3 and 4 Choose the color that best matches our ceiling fan 9 Position the reversing module supplied in the switch cup connect the reversing module connector to the motor connector Figure 6 The connectors are color coded and keyed and can be connected in only one manner Figure 6 10 Using a wir...

Страница 6: ...he wire Strip 1 2 inch of insulation from the end of this wire Then join the 80 yellow wire to the yellow wire from the uplight using a wire connector supplied Figure 9 NOTE The red and brown wires coming from the top of the motor are capped with wire connectors DO NOT remove these connectors 14A For Ceiling Fan Models CF2400 Only Cut the yellow wire midway between the motor coupling and the gromm...

Страница 7: ...rod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 22 17 Separate untwist and unkink the 80 white black and blue motor lead wires Route the three motor leads and the 80 yellow lead wire used only on fans with uplight through the downrod Seat the downrod firmly in the motor coupling Figure 11 18 Align the clevis pin holes in the downrod with the holes in the m...

Страница 8: ... securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING SETSCREW DOWNROD PIN HANGER BALL CEILING COVER Figure 13 24 Install the hanger bracket and hang the fan in accordance with the instructions in the Ceiling Fan Owner s Manual 25 Pull the wire leads coming from the end of the downrod and the supply wires through the open sid...

Страница 9: ...OFF REV D L U L YELLOW FAN WIRE FROM UPLIGHT Figure 15 27 Using wire connectors supplied make wiring connections as follows Figure 14 and 15 a Connect the green ground wires from the hanger bracket and the hanger ball to the supply ground wire bare or green b Connect the white fan wire and the white supply wire to the white receiver wire AC IN MOTOR N c Connect the black fan wire to the black rece...

Страница 10: ...ECEIVER CEILING COVER HANGER BRACKET 1 1 4 THREADED STUDS 2 Figure 16 Operation IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your remote control Figure 17 has full control of your fan and lights NOTE Prior to operation of the downlight from the remote control make sure the switch on the light is ON 1 To set the desir...

Страница 11: ...from excessive heat or humidity Trouble Shooting FAN LIGHT FAILS TO OPERATE Check that the light switch on the light fixture is on Check that the battery is good red indicator light should light when any button is pressed Check that the receiver is wired properly Check that the ON OFF wall switch is in the ON position Check that the receiver and transmitter code switches are set in the same positi...

Страница 12: ...e will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your remote control while in your possession or Unreasonable use misu...

Отзывы: