6.2
Unidrive SP / Commander GP20 trip descriptions
For further information on the above trips, see the
Diagnostics section of the
Unidrive
SP User Guide or the Commander GP20 User Guide
.
Trip no.
String
Diagnosis
200, 205,
210
SLX.HF
Solutions Module hardware fault
Ensure Solutions Module is fitted correctly
Return Soltutions Module to supplier
201, 206,
211
SLX.tO
Solutions Module watchdog time-out
Press reset
If the trip persists, contact the supplier of the drive
202, 207,
212
SLX.Er
Error detected with Solutions Module where X is the slot number
203, 208,
213
SLX.nF
Solutions Module has been removed
Ensure Solutions Module is fitted correctly
Save parameters and reset drive
Replace Solutions Module
204, 209,
214
SLX.dF
Solutions Module fitted in slot X has changed
Save parameters and reset
215
SL.rtd
Drive mode has changed and Solutions Module parameter
routing is now incorrect
Press reset
If the trip persists, contact the supplier of the drive
Pr x.50
Fault description
0
No errors
1
Digital outputs overloaded
2
Digital inputs overloaded
3
Communications Error
74
Solutions Module over temperature (>100
°
C)
Содержание SM-I/O 24V Protected
Страница 41: ......