28
SM-I/O 24V Protected User Guide
www.controltechniques.com
Issue Number: 2
*Digital input 4 destination only with Commander SK.
Source parameters define the parameter to be represented by the digital output
terminal.
Destination parameters define the parameter each of the programmable inputs is to
control.
*Parameter not available with Commander SK (T6 is a digital input only).
This parameter selects the function of terminal T6 as follows:
OFF (0) = digital input
On (1) = digital output
These parameters select the function of terminals T3 to T5 as follows:
OFF (0) = digital input
On (1) = digital output
x.21
T3 digital I/O 1 source/destination
x.22
T4 digital I/O 2 source/destination
x.23
T5 digital I/O 3 source/destination
x.24
T6 digital I/O 4 source/destination*
x.25
T7 digital input 5 destination
x.26
T8 digital input 6 destination
x.27
T9 digital input 7 destination
x.28
Relay 1 source
RW
Uni
DE
US
Ú
Pr
0.00
to Pr
21.51
Ö
Pr
0.00
Update rate: Read on drive reset
x.29*
T6 digital I/O 4 output select
RW
Bit
US
Ú
OFF (0) or On (1)
Ö
On (1)
Update rate: Background read
x.31
T3 digital I/O 1 output select
x.32
T4 digital I/O 2 output select
x.33
T5 digital I/O 3 output select
RW
Bit
US
Ú
OFF (0) or On (1)
Ö
OFF (0)
Update rate: Background read