0x6047 vl_velocity_min_max
This object is used to configure the minimum and maximum velocity.
The value is given in rpm if the vl_dimension_factor has the value of 1, otherwise the
value is in user units.
7.5.6
0x6048 vl_velocity_acceleration
This object is used to configure the delta speed and delta time of the slope of the
acceleration ramp.
Example: To ramp to 1000 rpm in 5s, possible values for delta speed and delta time
are 10000 and 50 respectively.
vl_velocity_acceleration = delta speed / delta time
Table 7.41 0x6047 vl_velocity_min_max
0x6047
vl_velocity_min_max
Sub-index 0
Access:
RO
Range:
N/A
Size:
Unsigned 8
Unit:
N/A
Default:
4
Description:
The number of last sub-indexes in this object.
Sub-index 1
Access:
RW
Range:
0 to 0xFFFFFFFF
Size:
Unsigned 32
Unit:
rpm
Default:
0
Description:
Used to configure the minimum positive velocity at which the system can operate.
Sub-index 2
Access:
RW
Range:
0 to 0xFFFFFFFF
Size:
Unsigned 32
Unit:
rpm
Default:
2147483647
Description:
Used to configure the maximum positive velocity at which the system can operate.
Sub-index 3
Access:
RW
Range:
0 to 0xFFFFFFFF
Size:
Unsigned 32
Unit:
rpm
Default:
0
Description:
Used to configure the minimum negative velocity at which the system can operate.
Sub-index 4
Access:
RW
Range:
0 to 0xFFFFFFFF
Size:
Unsigned 32
Unit:
rpm
Default:
2147483647
Description:
Used to configure the maximum negative velocity at which the system can operate.
Table 7.42 0x6048 vl_velocity_acceleration
0x6048
vl_velocity_acceleration
Sub-index 0
Access:
RO
Range:
N/A
Size:
Unsigned 8
Unit:
N/A
Default:
2
Description:
The number of last sub-indexes in this object.
Sub-index 1
Access:
RW
Range:
0 to 0xFFFFFFFF
Size:
Unsigned 32
Unit:
rpm
Default:
1000
Description:
The value of delta speed is given in rpm if the vl_dimension_factor and the
vl_setpoint_factor have the value 1, otherwise the value is in user units.
Sub-index 2
Access:
RW
Range:
0 to 65535
Size:
Unsigned 16
Unit:
s
Default:
2
Description:
The value of delta time is given in seconds.