206
Reference Manual
00809-0100-4021, Rev GC
Appendix A: Reference Data
April 2014
A.5
Ordering information
Table A-3. Rosemount
®
3144P Temperature Transmitter Ordering Information
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Model Product description
3144P
Temperature Transmitter
Housing style
Material
Conduit entry
size
Standard
Standard
D1
Field Mount Housing, Dual-Compartment Housing
Aluminum
1
/
2
–14 NPT
★
D2
Field Mount Housing, Dual-Compartment Housing
Aluminum
M20 x 1.5 (CM20)
★
D3
Field Mount Housing, Dual-Compartment Housing
Aluminum
PG 13.5 (PG11)
★
D4
Field Mount Housing, Dual-Compartment Housing
Aluminum
JIS G
1
/
2
★
D5
Field Mount Housing, Dual-Compartment Housing
Stainless Steel
1
/
2
–14 NPT
★
D6
Field Mount Housing, Dual-Compartment Housing
Stainless Steel
M20 x 1.5 (CM20)
★
D7
Field Mount Housing, Dual-Compartment Housing
Stainless Steel
PG 13.5 (PG11)
★
D8
Field Mount Housing, Dual-Compartment Housing
Stainless Steel
JIS G
1
/
2
★
Transmitter output
Standard
Standard
A
4-20 mA with digital signal based on HART protocol
★
F
F
OUNDATION
fieldbus digital signal (includes 3 AI function block and Backup Link Active Scheduler)
★
Measurement configuration
Standard
Standard
1
Single-Sensor Input
★
2
Dual-Sensor Input
★
Product certifications
Standard
Standard
NA
No Approval
★
E5
FM Explosion-proof, Dust Ignition-Proof, and Non-incendive approval
★
I5
FM Intrinsically Safe and Non-incendive (includes standard IS and FISCO for fieldbus units)
★
FM IS, Non-incendive & Explosion-proof combo (includes standard IS and FISCO for fieldbus units)
★
FM and CSA IS, Explosion-proof, and Non-incendive combo (includes standard IS and FISCO for FF
units)
★
I6
CSA Intrinsically Safe/FISCO and Division 2 (includes standard IS and FISCO for fieldbus units)
★
CSA IS, FISCO Division 2 and Explosion-proof combo (includes standard IS, FISCO for fieldbus units)
★
E1
ATEX Flameproof approval
★
N1
ATEX type n approval
★
I1
ATEX intrinsic safety approval (includes standard IS and FISCO for fieldbus units)
★
Содержание Rosemount
Страница 1: ...Reference Manual 00809 0100 4021 Rev GC April 2014 Rosemount 3144P Temperature Transmitter ...
Страница 2: ......
Страница 4: ...iv Reference Manual 00809 0100 4021 Rev GC Title Page April 2014 ...
Страница 10: ...x Reference Manual 00809 0100 4021 Rev GC Table of Contents April 2014 Table of Contents ...
Страница 38: ...28 Reference Manual 00809 0100 4021 Rev GC Section 2 Installation April 2014 Installation ...
Страница 188: ...178 Reference Manual 00809 0100 4021 Rev GC Section 5 Maintenance April 2014 Maintenance ...
Страница 233: ...227 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 234: ...228 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 235: ...229 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 237: ...231 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 238: ...232 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 244: ...238 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 250: ...Index 244 Reference Manual 00809 0100 4021 Rev GC Index April 2014 Index ...
Страница 251: ......