Table 10-2: Transmitter
Extension
length
Process temperature (°C)
Gas
Dust
T6
T5
T4
T3
T2
T1
T130 °C
No
extention
55
70
100
170
280
440
100
3-in.
extension
55
70
110
190
300
450
110
6-in.
extension
60
70
120
200
300
450
110
9-in
extension
65
75
130
200
300
450
120
Adhering to the process temperature limitations of
will ensure
that the service temperature limitations of the LCD cover are not exceeded.
Process temperatures may exceed the limits defined in
if the
temperature of the LCD cover is verified to not exceed the service
temperatures in
and the process temperatures do not exceed the
Table 10-3: Transmitter with LCD Cover - Process Temperature (°C)
Extension length
Gas
Dust
T6
T5
T4...T1
T130 °C
No extension
55
70
95
95
3-in. extension
55
70
100
100
6-in. extension
60
70
100
100
9-in. extension
65
75
110
110
Table 10-4: Transmitter with LCD Cover - Service Temperature (°C)
Extension length
Gas
Dust
T6
T5
T4...T1
T130 °C
No extension
65
75
95
95